Cargando…

Late Intraluminal Stent Application in Strictures due to Corrosive Esophagitis: Our Preliminary Experiences

OBJECTIVES: Household chemicals result in corrosive esophageal burns in the developing third world countries, and most of them cause esophageal strictures. There is no standard treatment for esophageal strictures. Here, we present our preliminary experience with intraluminal esophageal stents for st...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaba, Meltem, Karadag, Cetin Ali, Demir, Mesut, Sever, Nihat, Akin, Melih, Dokucu, Ali Ihsan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kare Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7326674/
https://www.ncbi.nlm.nih.gov/pubmed/32617054
http://dx.doi.org/10.14744/SEMB.2018.09634
_version_ 1783552387177250816
author Kaba, Meltem
Karadag, Cetin Ali
Demir, Mesut
Sever, Nihat
Akin, Melih
Dokucu, Ali Ihsan
author_facet Kaba, Meltem
Karadag, Cetin Ali
Demir, Mesut
Sever, Nihat
Akin, Melih
Dokucu, Ali Ihsan
author_sort Kaba, Meltem
collection PubMed
description OBJECTIVES: Household chemicals result in corrosive esophageal burns in the developing third world countries, and most of them cause esophageal strictures. There is no standard treatment for esophageal strictures. Here, we present our preliminary experience with intraluminal esophageal stents for stricture treatment. METHODS: The files of the patients who had stenosis due to corrosive esophagitis in our clinic were evaluated retrospectively. Stricture lengths were between 30 and 130 mm. Stents were self-expandable, made of nitinol alloy that was covered with silicone, and they were cylindrical in shape with a conical tip. The lengths varied between 60 and 170 mm and the diameters were between 10-20 mm. The stent application was made under general anaesthesia. RESULTS: There were seven patients (four girls and three boys). After stent application, all patients experienced constant or temporary pain, vomiting, and difficulty in swallowing. Bleeding occurred in one patient. Sudden death occurred in one patient, probably as a complication of chest infection. All stents had to be removed in mean 38 days because of embedding of the stent, development of granulation tissue and intolerance. CONCLUSION: More research is needed to determine the type, length and diameter of the stent, the timing and the duration of the application, the length and level of the stricture suitable for stent application and medications during treatment.
format Online
Article
Text
id pubmed-7326674
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Kare Publishing
record_format MEDLINE/PubMed
spelling pubmed-73266742020-07-01 Late Intraluminal Stent Application in Strictures due to Corrosive Esophagitis: Our Preliminary Experiences Kaba, Meltem Karadag, Cetin Ali Demir, Mesut Sever, Nihat Akin, Melih Dokucu, Ali Ihsan Sisli Etfal Hastan Tip Bul Original Research OBJECTIVES: Household chemicals result in corrosive esophageal burns in the developing third world countries, and most of them cause esophageal strictures. There is no standard treatment for esophageal strictures. Here, we present our preliminary experience with intraluminal esophageal stents for stricture treatment. METHODS: The files of the patients who had stenosis due to corrosive esophagitis in our clinic were evaluated retrospectively. Stricture lengths were between 30 and 130 mm. Stents were self-expandable, made of nitinol alloy that was covered with silicone, and they were cylindrical in shape with a conical tip. The lengths varied between 60 and 170 mm and the diameters were between 10-20 mm. The stent application was made under general anaesthesia. RESULTS: There were seven patients (four girls and three boys). After stent application, all patients experienced constant or temporary pain, vomiting, and difficulty in swallowing. Bleeding occurred in one patient. Sudden death occurred in one patient, probably as a complication of chest infection. All stents had to be removed in mean 38 days because of embedding of the stent, development of granulation tissue and intolerance. CONCLUSION: More research is needed to determine the type, length and diameter of the stent, the timing and the duration of the application, the length and level of the stricture suitable for stent application and medications during treatment. Kare Publishing 2020-05-15 /pmc/articles/PMC7326674/ /pubmed/32617054 http://dx.doi.org/10.14744/SEMB.2018.09634 Text en Copyright: © 2020 by The Medical Bulletin of Sisli Etfal Hospital http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
spellingShingle Original Research
Kaba, Meltem
Karadag, Cetin Ali
Demir, Mesut
Sever, Nihat
Akin, Melih
Dokucu, Ali Ihsan
Late Intraluminal Stent Application in Strictures due to Corrosive Esophagitis: Our Preliminary Experiences
title Late Intraluminal Stent Application in Strictures due to Corrosive Esophagitis: Our Preliminary Experiences
title_full Late Intraluminal Stent Application in Strictures due to Corrosive Esophagitis: Our Preliminary Experiences
title_fullStr Late Intraluminal Stent Application in Strictures due to Corrosive Esophagitis: Our Preliminary Experiences
title_full_unstemmed Late Intraluminal Stent Application in Strictures due to Corrosive Esophagitis: Our Preliminary Experiences
title_short Late Intraluminal Stent Application in Strictures due to Corrosive Esophagitis: Our Preliminary Experiences
title_sort late intraluminal stent application in strictures due to corrosive esophagitis: our preliminary experiences
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7326674/
https://www.ncbi.nlm.nih.gov/pubmed/32617054
http://dx.doi.org/10.14744/SEMB.2018.09634
work_keys_str_mv AT kabameltem lateintraluminalstentapplicationinstricturesduetocorrosiveesophagitisourpreliminaryexperiences
AT karadagcetinali lateintraluminalstentapplicationinstricturesduetocorrosiveesophagitisourpreliminaryexperiences
AT demirmesut lateintraluminalstentapplicationinstricturesduetocorrosiveesophagitisourpreliminaryexperiences
AT severnihat lateintraluminalstentapplicationinstricturesduetocorrosiveesophagitisourpreliminaryexperiences
AT akinmelih lateintraluminalstentapplicationinstricturesduetocorrosiveesophagitisourpreliminaryexperiences
AT dokucualiihsan lateintraluminalstentapplicationinstricturesduetocorrosiveesophagitisourpreliminaryexperiences