Cargando…

Relationship between the Molecular Coil Dimension and the Energy Storage Modulus of Polymer Solution Configured with Oilfield-Produced Sewage

Polymer viscoelastic solution is the non-Newtonian fluid and widely used in oil production. In the process of seepage, the mechanism of the polymer solution with different molecular coil dimensions (Dh) flooding on remaining oil is unknown. By using the dynamic light scattering instrument, the molec...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Peng, Ma, Wenguo, Zhang, Yunbao, Yan, Qiuyan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7327564/
https://www.ncbi.nlm.nih.gov/pubmed/32655643
http://dx.doi.org/10.1155/2020/2538521
_version_ 1783552569426051072
author Wang, Peng
Ma, Wenguo
Zhang, Yunbao
Yan, Qiuyan
author_facet Wang, Peng
Ma, Wenguo
Zhang, Yunbao
Yan, Qiuyan
author_sort Wang, Peng
collection PubMed
description Polymer viscoelastic solution is the non-Newtonian fluid and widely used in oil production. In the process of seepage, the mechanism of the polymer solution with different molecular coil dimensions (Dh) flooding on remaining oil is unknown. By using the dynamic light scattering instrument, the molecular coil dimension of the polymer solution is tested. By using the HAAKE rheometer, the creep recovery test data of the polymer solution under the same creep time condition are obtained. The effects of polymer solutions with different Dh on residual oil are observed, by using the visible pore model. The results show that the higher the molecular weight (M(w)) of the polymer, the larger the size of the molecular coil dimension. The elasticity characteristics of the polymer solution are sensitive to the molecular coil dimension. As Dh of polymer molecules becomes larger, the contribution of the elastic portion to the viscosity of the polymer solution increases. The higher the M(w) of polymer is, the longer the molecular chain is and the size of Dh is larger. On the condition of the polymer solution with different M(w) with 2.5 g/L, when Dh is between 320.0 nm and 327.8 nm, the ratio of the elastic part in the apparent viscosity exceeds the proportion of the viscous part, and the polymer solution composition after these data can be used as a comparative study of elasticity for residual oil use. In the visible pore model, the pore-throat ratio is 3.5, the E(R) of water flooding is 54.26%, the E(R) of the polymer solution with Dh = 159.7 nm is 75.28%, and the increase of E(R) is 21.02% than that of water flooding. With the increase of Dh to 327.8 nm, the final E(R) of the experimental polymer solution is 97.82%, and the increase of E(R) of the polymer solution than that of water flooding is 43.56%. However, in the model with a pore-throat ratio of 7.0 and the same polymer solution with Dh = 327.8 nm, the increase of E(R) of the polymer solution is only 10.44% higher than that of water flooding. The effect of the polymer solution with the same Dh is deteriorated with the increase of the pore-throat ratio.
format Online
Article
Text
id pubmed-7327564
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-73275642020-07-09 Relationship between the Molecular Coil Dimension and the Energy Storage Modulus of Polymer Solution Configured with Oilfield-Produced Sewage Wang, Peng Ma, Wenguo Zhang, Yunbao Yan, Qiuyan Int J Anal Chem Research Article Polymer viscoelastic solution is the non-Newtonian fluid and widely used in oil production. In the process of seepage, the mechanism of the polymer solution with different molecular coil dimensions (Dh) flooding on remaining oil is unknown. By using the dynamic light scattering instrument, the molecular coil dimension of the polymer solution is tested. By using the HAAKE rheometer, the creep recovery test data of the polymer solution under the same creep time condition are obtained. The effects of polymer solutions with different Dh on residual oil are observed, by using the visible pore model. The results show that the higher the molecular weight (M(w)) of the polymer, the larger the size of the molecular coil dimension. The elasticity characteristics of the polymer solution are sensitive to the molecular coil dimension. As Dh of polymer molecules becomes larger, the contribution of the elastic portion to the viscosity of the polymer solution increases. The higher the M(w) of polymer is, the longer the molecular chain is and the size of Dh is larger. On the condition of the polymer solution with different M(w) with 2.5 g/L, when Dh is between 320.0 nm and 327.8 nm, the ratio of the elastic part in the apparent viscosity exceeds the proportion of the viscous part, and the polymer solution composition after these data can be used as a comparative study of elasticity for residual oil use. In the visible pore model, the pore-throat ratio is 3.5, the E(R) of water flooding is 54.26%, the E(R) of the polymer solution with Dh = 159.7 nm is 75.28%, and the increase of E(R) is 21.02% than that of water flooding. With the increase of Dh to 327.8 nm, the final E(R) of the experimental polymer solution is 97.82%, and the increase of E(R) of the polymer solution than that of water flooding is 43.56%. However, in the model with a pore-throat ratio of 7.0 and the same polymer solution with Dh = 327.8 nm, the increase of E(R) of the polymer solution is only 10.44% higher than that of water flooding. The effect of the polymer solution with the same Dh is deteriorated with the increase of the pore-throat ratio. Hindawi 2020-06-22 /pmc/articles/PMC7327564/ /pubmed/32655643 http://dx.doi.org/10.1155/2020/2538521 Text en Copyright © 2020 Peng Wang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Wang, Peng
Ma, Wenguo
Zhang, Yunbao
Yan, Qiuyan
Relationship between the Molecular Coil Dimension and the Energy Storage Modulus of Polymer Solution Configured with Oilfield-Produced Sewage
title Relationship between the Molecular Coil Dimension and the Energy Storage Modulus of Polymer Solution Configured with Oilfield-Produced Sewage
title_full Relationship between the Molecular Coil Dimension and the Energy Storage Modulus of Polymer Solution Configured with Oilfield-Produced Sewage
title_fullStr Relationship between the Molecular Coil Dimension and the Energy Storage Modulus of Polymer Solution Configured with Oilfield-Produced Sewage
title_full_unstemmed Relationship between the Molecular Coil Dimension and the Energy Storage Modulus of Polymer Solution Configured with Oilfield-Produced Sewage
title_short Relationship between the Molecular Coil Dimension and the Energy Storage Modulus of Polymer Solution Configured with Oilfield-Produced Sewage
title_sort relationship between the molecular coil dimension and the energy storage modulus of polymer solution configured with oilfield-produced sewage
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7327564/
https://www.ncbi.nlm.nih.gov/pubmed/32655643
http://dx.doi.org/10.1155/2020/2538521
work_keys_str_mv AT wangpeng relationshipbetweenthemolecularcoildimensionandtheenergystoragemodulusofpolymersolutionconfiguredwithoilfieldproducedsewage
AT mawenguo relationshipbetweenthemolecularcoildimensionandtheenergystoragemodulusofpolymersolutionconfiguredwithoilfieldproducedsewage
AT zhangyunbao relationshipbetweenthemolecularcoildimensionandtheenergystoragemodulusofpolymersolutionconfiguredwithoilfieldproducedsewage
AT yanqiuyan relationshipbetweenthemolecularcoildimensionandtheenergystoragemodulusofpolymersolutionconfiguredwithoilfieldproducedsewage