Cargando…
Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors
Concrete structures expand and contract in response to temperature changes which can result in structural strain and cracking. However, there is a limited amount of robust field data on hybrid concrete floor structures. Shortage of such data impacts on our understanding of how concrete structures re...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Singapore
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7328017/ https://www.ncbi.nlm.nih.gov/pubmed/32647559 http://dx.doi.org/10.1186/s40069-018-0287-y |
_version_ | 1783552671648579584 |
---|---|
author | Newell, Shane Goggins, Jamie |
author_facet | Newell, Shane Goggins, Jamie |
author_sort | Newell, Shane |
collection | PubMed |
description | Concrete structures expand and contract in response to temperature changes which can result in structural strain and cracking. However, there is a limited amount of robust field data on hybrid concrete floor structures. Shortage of such data impacts on our understanding of how concrete structures respond to thermal effects and ultimately the overall design of concrete structures. Thus, a comprehensive structural and environmental monitoring strategy was implemented by the authors during the construction of an educational building. Sensors were embedded in the precast and in situ components of a hybrid concrete lattice girder flat slab so that the thermal response of the floor during the manufacture, construction and operational stages could be investigated. Many aspects of the thermal behaviour of the floor during the construction phase were monitored using the embedded sensors. The early-age thermal effects during curing and the impact of the variation of ambient temperature (daily and seasonal) and solar radiation on the behaviour of concrete floor is explored in the paper. Values for restraint factors and the in situ restrained coefficient of thermal expansion of concrete are calculated using the data from the embedded sensors. Numerical modelling of the thermal behaviour of the hybrid concrete floor was undertaken and validated using the real-time field measurements. The data presented and analysed in this paper can be used to improve the understanding and modelling of the thermal behaviour of a hybrid concrete floor. This will assist with improved design of sustainable buildings as it allows the environmental performance of the floor to be optimised with respect to controlling the internal environment, thermal mass and energy efficiency. |
format | Online Article Text |
id | pubmed-7328017 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer Singapore |
record_format | MEDLINE/PubMed |
spelling | pubmed-73280172020-07-07 Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors Newell, Shane Goggins, Jamie Int J Concr Struct Mater Original Article Concrete structures expand and contract in response to temperature changes which can result in structural strain and cracking. However, there is a limited amount of robust field data on hybrid concrete floor structures. Shortage of such data impacts on our understanding of how concrete structures respond to thermal effects and ultimately the overall design of concrete structures. Thus, a comprehensive structural and environmental monitoring strategy was implemented by the authors during the construction of an educational building. Sensors were embedded in the precast and in situ components of a hybrid concrete lattice girder flat slab so that the thermal response of the floor during the manufacture, construction and operational stages could be investigated. Many aspects of the thermal behaviour of the floor during the construction phase were monitored using the embedded sensors. The early-age thermal effects during curing and the impact of the variation of ambient temperature (daily and seasonal) and solar radiation on the behaviour of concrete floor is explored in the paper. Values for restraint factors and the in situ restrained coefficient of thermal expansion of concrete are calculated using the data from the embedded sensors. Numerical modelling of the thermal behaviour of the hybrid concrete floor was undertaken and validated using the real-time field measurements. The data presented and analysed in this paper can be used to improve the understanding and modelling of the thermal behaviour of a hybrid concrete floor. This will assist with improved design of sustainable buildings as it allows the environmental performance of the floor to be optimised with respect to controlling the internal environment, thermal mass and energy efficiency. Springer Singapore 2018-10-05 2018 /pmc/articles/PMC7328017/ /pubmed/32647559 http://dx.doi.org/10.1186/s40069-018-0287-y Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Newell, Shane Goggins, Jamie Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors |
title | Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors |
title_full | Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors |
title_fullStr | Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors |
title_full_unstemmed | Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors |
title_short | Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors |
title_sort | investigation of thermal behaviour of a hybrid precasted concrete floor using embedded sensors |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7328017/ https://www.ncbi.nlm.nih.gov/pubmed/32647559 http://dx.doi.org/10.1186/s40069-018-0287-y |
work_keys_str_mv | AT newellshane investigationofthermalbehaviourofahybridprecastedconcretefloorusingembeddedsensors AT gogginsjamie investigationofthermalbehaviourofahybridprecastedconcretefloorusingembeddedsensors |