Cargando…
Cerebrospinal Fluid Leaks and Pseudomeningocele after Posterior Fossa Surgery: Effect of an Autospray Dural Sealant
Background Posterior fossa craniotomies can be complicated by cerebrospinal fluid (CSF) leaks, infection, meningitis, neurologic deficits, and intracranial hypotension caused by defective closure of the dura. Secondary dural closures such as pericranial graft, muscle graft, glue, sealants, or fat gr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7328695/ https://www.ncbi.nlm.nih.gov/pubmed/32626623 http://dx.doi.org/10.7759/cureus.8379 |
_version_ | 1783552778479599616 |
---|---|
author | Lee, Young M Ordaz, Angel Durcanova, Beata Viner, Jennifer A Theodosopoulos, Philip V Aghi, Manish K McDermott, Michael W. |
author_facet | Lee, Young M Ordaz, Angel Durcanova, Beata Viner, Jennifer A Theodosopoulos, Philip V Aghi, Manish K McDermott, Michael W. |
author_sort | Lee, Young M |
collection | PubMed |
description | Background Posterior fossa craniotomies can be complicated by cerebrospinal fluid (CSF) leaks, infection, meningitis, neurologic deficits, and intracranial hypotension caused by defective closure of the dura. Secondary dural closures such as pericranial graft, muscle graft, glue, sealants, or fat graft are used. However, there have been few studies examining the use of sealants with a polyethylene glycol and polyethylenimine component. Objective We studied the effect of one such sealant, Adherus® (HyperBranch Medical Technology, Durham, NC, USA), as an adjunct to secondary closure methods in the reduction of the use of abdominal fat grafting and lumbar puncture/drains. Methods We retrospectively reviewed the surgical records of all patients undergoing posterior fossa cranial surgery during a two-year period at a tertiary university affiliated medical center. Results Overall, data a total of 122 patients (62 in the no Adherus and 60 in the Adherus group) were collected. There was no statistically significant difference in the 30-day incisional CSF leak rate (4.1% vs. 6.5%; p=0.183), 30-day non-incisional CSF leak rate (11.3% vs. 5.0%; p=0.205), and 30-day pseudomeningocele rate (16.1% vs. 13.3%; p=0.663) in the no Adherus and Adherus groups, respectively. However, there was a significant reduction in the use of abdominal fat grafting (0% vs. 30.7%; p<0.001) and intraoperative CSF diversion techniques (58.1% vs. 23.3%; p<0.001). Every instance of the use of Adherus saved on average, $809.36. Conclusions A statistically significant reduction in the use of CSF shunting procedures during posterior fossa craniotomy/craniectomy was achieved after the introduction of Adherus with no increase in CSF leak rate. |
format | Online Article Text |
id | pubmed-7328695 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-73286952020-07-02 Cerebrospinal Fluid Leaks and Pseudomeningocele after Posterior Fossa Surgery: Effect of an Autospray Dural Sealant Lee, Young M Ordaz, Angel Durcanova, Beata Viner, Jennifer A Theodosopoulos, Philip V Aghi, Manish K McDermott, Michael W. Cureus Miscellaneous Background Posterior fossa craniotomies can be complicated by cerebrospinal fluid (CSF) leaks, infection, meningitis, neurologic deficits, and intracranial hypotension caused by defective closure of the dura. Secondary dural closures such as pericranial graft, muscle graft, glue, sealants, or fat graft are used. However, there have been few studies examining the use of sealants with a polyethylene glycol and polyethylenimine component. Objective We studied the effect of one such sealant, Adherus® (HyperBranch Medical Technology, Durham, NC, USA), as an adjunct to secondary closure methods in the reduction of the use of abdominal fat grafting and lumbar puncture/drains. Methods We retrospectively reviewed the surgical records of all patients undergoing posterior fossa cranial surgery during a two-year period at a tertiary university affiliated medical center. Results Overall, data a total of 122 patients (62 in the no Adherus and 60 in the Adherus group) were collected. There was no statistically significant difference in the 30-day incisional CSF leak rate (4.1% vs. 6.5%; p=0.183), 30-day non-incisional CSF leak rate (11.3% vs. 5.0%; p=0.205), and 30-day pseudomeningocele rate (16.1% vs. 13.3%; p=0.663) in the no Adherus and Adherus groups, respectively. However, there was a significant reduction in the use of abdominal fat grafting (0% vs. 30.7%; p<0.001) and intraoperative CSF diversion techniques (58.1% vs. 23.3%; p<0.001). Every instance of the use of Adherus saved on average, $809.36. Conclusions A statistically significant reduction in the use of CSF shunting procedures during posterior fossa craniotomy/craniectomy was achieved after the introduction of Adherus with no increase in CSF leak rate. Cureus 2020-05-31 /pmc/articles/PMC7328695/ /pubmed/32626623 http://dx.doi.org/10.7759/cureus.8379 Text en Copyright © 2020, Lee et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Miscellaneous Lee, Young M Ordaz, Angel Durcanova, Beata Viner, Jennifer A Theodosopoulos, Philip V Aghi, Manish K McDermott, Michael W. Cerebrospinal Fluid Leaks and Pseudomeningocele after Posterior Fossa Surgery: Effect of an Autospray Dural Sealant |
title | Cerebrospinal Fluid Leaks and Pseudomeningocele after Posterior Fossa Surgery: Effect of an Autospray Dural Sealant |
title_full | Cerebrospinal Fluid Leaks and Pseudomeningocele after Posterior Fossa Surgery: Effect of an Autospray Dural Sealant |
title_fullStr | Cerebrospinal Fluid Leaks and Pseudomeningocele after Posterior Fossa Surgery: Effect of an Autospray Dural Sealant |
title_full_unstemmed | Cerebrospinal Fluid Leaks and Pseudomeningocele after Posterior Fossa Surgery: Effect of an Autospray Dural Sealant |
title_short | Cerebrospinal Fluid Leaks and Pseudomeningocele after Posterior Fossa Surgery: Effect of an Autospray Dural Sealant |
title_sort | cerebrospinal fluid leaks and pseudomeningocele after posterior fossa surgery: effect of an autospray dural sealant |
topic | Miscellaneous |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7328695/ https://www.ncbi.nlm.nih.gov/pubmed/32626623 http://dx.doi.org/10.7759/cureus.8379 |
work_keys_str_mv | AT leeyoungm cerebrospinalfluidleaksandpseudomeningoceleafterposteriorfossasurgeryeffectofanautosprayduralsealant AT ordazangel cerebrospinalfluidleaksandpseudomeningoceleafterposteriorfossasurgeryeffectofanautosprayduralsealant AT durcanovabeata cerebrospinalfluidleaksandpseudomeningoceleafterposteriorfossasurgeryeffectofanautosprayduralsealant AT vinerjennifera cerebrospinalfluidleaksandpseudomeningoceleafterposteriorfossasurgeryeffectofanautosprayduralsealant AT theodosopoulosphilipv cerebrospinalfluidleaksandpseudomeningoceleafterposteriorfossasurgeryeffectofanautosprayduralsealant AT aghimanishk cerebrospinalfluidleaksandpseudomeningoceleafterposteriorfossasurgeryeffectofanautosprayduralsealant AT mcdermottmichaelw cerebrospinalfluidleaksandpseudomeningoceleafterposteriorfossasurgeryeffectofanautosprayduralsealant |