Cargando…
Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI
Precise procedural planning is crucial to achieve excellent results in patients undergoing Transcatheter aortic valve implantation (TAVI). The aim of this study was to compare the semi-automated 3mensio (3 m) software to the fully-automated HeartNavigator3 (HN) software. We randomly selected 100 pat...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7329903/ https://www.ncbi.nlm.nih.gov/pubmed/32612266 http://dx.doi.org/10.1038/s41598-020-67111-5 |
_version_ | 1783552997737889792 |
---|---|
author | Meyer, Alexander Kofler, Markus Montagner, Matteo Unbehaun, Axel Sündermann, Simon Buz, Semih Klein, Christoph Stamm, Christof Solowjowa, Natalia Emmert, Maximilian Y. Falk, Volkmar Kempfert, Jörg |
author_facet | Meyer, Alexander Kofler, Markus Montagner, Matteo Unbehaun, Axel Sündermann, Simon Buz, Semih Klein, Christoph Stamm, Christof Solowjowa, Natalia Emmert, Maximilian Y. Falk, Volkmar Kempfert, Jörg |
author_sort | Meyer, Alexander |
collection | PubMed |
description | Precise procedural planning is crucial to achieve excellent results in patients undergoing Transcatheter aortic valve implantation (TAVI). The aim of this study was to compare the semi-automated 3mensio (3 m) software to the fully-automated HeartNavigator3 (HN) software. We randomly selected 100 patients from our in-house TAVI-registry and compared aortic annulus and perimeter as well as coronary distances between 3m-measurements and post-hoc HN-measurements. Finally, we retrospectively simulated prosthesis choice based on HN-measurements and analyzed the differences compared to routinely used 3 m based strategy. We observed significant differences between the two software packages regarding area (3 m 464 ± 88 mm², HN 482 ± 96 mm², p < 0.001), perimeter (3 m 77 ± 7 mm, HN 79 ± 8 mm, p < 0.001) and coronary distances (LCA: 3 m 13 ± 3 mm, HN 12 ± 3 mm, p < 0.001; RCA: 3 m 16 ± 3 mm, HN 15 ± 3 mm, p < 0.001). Prosthesis choice simulation based on newly obtained HN-measurements would have led to a decision change in 18% of patients, with a further reduction to 4% following manual adjustment of HN-measurements. The fully-automatic HN-software provides higher values for annular metrics and lower annulus-to-coronary-ostia distances compared to 3m-software. Measurement differences did not influence clinical outcome. Both, the HN-software and the 3m-software are sophisticated, reliable and easy to use for the clinician. Manual adjustment of HN-measurements may increase precision in complex aortic annulus anatomy. |
format | Online Article Text |
id | pubmed-7329903 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-73299032020-07-06 Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI Meyer, Alexander Kofler, Markus Montagner, Matteo Unbehaun, Axel Sündermann, Simon Buz, Semih Klein, Christoph Stamm, Christof Solowjowa, Natalia Emmert, Maximilian Y. Falk, Volkmar Kempfert, Jörg Sci Rep Article Precise procedural planning is crucial to achieve excellent results in patients undergoing Transcatheter aortic valve implantation (TAVI). The aim of this study was to compare the semi-automated 3mensio (3 m) software to the fully-automated HeartNavigator3 (HN) software. We randomly selected 100 patients from our in-house TAVI-registry and compared aortic annulus and perimeter as well as coronary distances between 3m-measurements and post-hoc HN-measurements. Finally, we retrospectively simulated prosthesis choice based on HN-measurements and analyzed the differences compared to routinely used 3 m based strategy. We observed significant differences between the two software packages regarding area (3 m 464 ± 88 mm², HN 482 ± 96 mm², p < 0.001), perimeter (3 m 77 ± 7 mm, HN 79 ± 8 mm, p < 0.001) and coronary distances (LCA: 3 m 13 ± 3 mm, HN 12 ± 3 mm, p < 0.001; RCA: 3 m 16 ± 3 mm, HN 15 ± 3 mm, p < 0.001). Prosthesis choice simulation based on newly obtained HN-measurements would have led to a decision change in 18% of patients, with a further reduction to 4% following manual adjustment of HN-measurements. The fully-automatic HN-software provides higher values for annular metrics and lower annulus-to-coronary-ostia distances compared to 3m-software. Measurement differences did not influence clinical outcome. Both, the HN-software and the 3m-software are sophisticated, reliable and easy to use for the clinician. Manual adjustment of HN-measurements may increase precision in complex aortic annulus anatomy. Nature Publishing Group UK 2020-07-01 /pmc/articles/PMC7329903/ /pubmed/32612266 http://dx.doi.org/10.1038/s41598-020-67111-5 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Meyer, Alexander Kofler, Markus Montagner, Matteo Unbehaun, Axel Sündermann, Simon Buz, Semih Klein, Christoph Stamm, Christof Solowjowa, Natalia Emmert, Maximilian Y. Falk, Volkmar Kempfert, Jörg Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI |
title | Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI |
title_full | Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI |
title_fullStr | Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI |
title_full_unstemmed | Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI |
title_short | Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI |
title_sort | reliability and influence on decision making of fully-automated vs. semi-automated software packages for procedural planning in tavi |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7329903/ https://www.ncbi.nlm.nih.gov/pubmed/32612266 http://dx.doi.org/10.1038/s41598-020-67111-5 |
work_keys_str_mv | AT meyeralexander reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT koflermarkus reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT montagnermatteo reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT unbehaunaxel reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT sundermannsimon reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT buzsemih reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT kleinchristoph reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT stammchristof reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT solowjowanatalia reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT emmertmaximiliany reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT falkvolkmar reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi AT kempfertjorg reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi |