Cargando…

Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI

Precise procedural planning is crucial to achieve excellent results in patients undergoing Transcatheter aortic valve implantation (TAVI). The aim of this study was to compare the semi-automated 3mensio (3 m) software to the fully-automated HeartNavigator3 (HN) software. We randomly selected 100 pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Meyer, Alexander, Kofler, Markus, Montagner, Matteo, Unbehaun, Axel, Sündermann, Simon, Buz, Semih, Klein, Christoph, Stamm, Christof, Solowjowa, Natalia, Emmert, Maximilian Y., Falk, Volkmar, Kempfert, Jörg
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7329903/
https://www.ncbi.nlm.nih.gov/pubmed/32612266
http://dx.doi.org/10.1038/s41598-020-67111-5
_version_ 1783552997737889792
author Meyer, Alexander
Kofler, Markus
Montagner, Matteo
Unbehaun, Axel
Sündermann, Simon
Buz, Semih
Klein, Christoph
Stamm, Christof
Solowjowa, Natalia
Emmert, Maximilian Y.
Falk, Volkmar
Kempfert, Jörg
author_facet Meyer, Alexander
Kofler, Markus
Montagner, Matteo
Unbehaun, Axel
Sündermann, Simon
Buz, Semih
Klein, Christoph
Stamm, Christof
Solowjowa, Natalia
Emmert, Maximilian Y.
Falk, Volkmar
Kempfert, Jörg
author_sort Meyer, Alexander
collection PubMed
description Precise procedural planning is crucial to achieve excellent results in patients undergoing Transcatheter aortic valve implantation (TAVI). The aim of this study was to compare the semi-automated 3mensio (3 m) software to the fully-automated HeartNavigator3 (HN) software. We randomly selected 100 patients from our in-house TAVI-registry and compared aortic annulus and perimeter as well as coronary distances between 3m-measurements and post-hoc HN-measurements. Finally, we retrospectively simulated prosthesis choice based on HN-measurements and analyzed the differences compared to routinely used 3 m based strategy. We observed significant differences between the two software packages regarding area (3 m 464 ± 88 mm², HN 482 ± 96 mm², p < 0.001), perimeter (3 m 77 ± 7 mm, HN 79 ± 8 mm, p < 0.001) and coronary distances (LCA: 3 m 13 ± 3 mm, HN 12 ± 3 mm, p < 0.001; RCA: 3 m 16 ± 3 mm, HN 15 ± 3 mm, p < 0.001). Prosthesis choice simulation based on newly obtained HN-measurements would have led to a decision change in 18% of patients, with a further reduction to 4% following manual adjustment of HN-measurements. The fully-automatic HN-software provides higher values for annular metrics and lower annulus-to-coronary-ostia distances compared to 3m-software. Measurement differences did not influence clinical outcome. Both, the HN-software and the 3m-software are sophisticated, reliable and easy to use for the clinician. Manual adjustment of HN-measurements may increase precision in complex aortic annulus anatomy.
format Online
Article
Text
id pubmed-7329903
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-73299032020-07-06 Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI Meyer, Alexander Kofler, Markus Montagner, Matteo Unbehaun, Axel Sündermann, Simon Buz, Semih Klein, Christoph Stamm, Christof Solowjowa, Natalia Emmert, Maximilian Y. Falk, Volkmar Kempfert, Jörg Sci Rep Article Precise procedural planning is crucial to achieve excellent results in patients undergoing Transcatheter aortic valve implantation (TAVI). The aim of this study was to compare the semi-automated 3mensio (3 m) software to the fully-automated HeartNavigator3 (HN) software. We randomly selected 100 patients from our in-house TAVI-registry and compared aortic annulus and perimeter as well as coronary distances between 3m-measurements and post-hoc HN-measurements. Finally, we retrospectively simulated prosthesis choice based on HN-measurements and analyzed the differences compared to routinely used 3 m based strategy. We observed significant differences between the two software packages regarding area (3 m 464 ± 88 mm², HN 482 ± 96 mm², p < 0.001), perimeter (3 m 77 ± 7 mm, HN 79 ± 8 mm, p < 0.001) and coronary distances (LCA: 3 m 13 ± 3 mm, HN 12 ± 3 mm, p < 0.001; RCA: 3 m 16 ± 3 mm, HN 15 ± 3 mm, p < 0.001). Prosthesis choice simulation based on newly obtained HN-measurements would have led to a decision change in 18% of patients, with a further reduction to 4% following manual adjustment of HN-measurements. The fully-automatic HN-software provides higher values for annular metrics and lower annulus-to-coronary-ostia distances compared to 3m-software. Measurement differences did not influence clinical outcome. Both, the HN-software and the 3m-software are sophisticated, reliable and easy to use for the clinician. Manual adjustment of HN-measurements may increase precision in complex aortic annulus anatomy. Nature Publishing Group UK 2020-07-01 /pmc/articles/PMC7329903/ /pubmed/32612266 http://dx.doi.org/10.1038/s41598-020-67111-5 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Meyer, Alexander
Kofler, Markus
Montagner, Matteo
Unbehaun, Axel
Sündermann, Simon
Buz, Semih
Klein, Christoph
Stamm, Christof
Solowjowa, Natalia
Emmert, Maximilian Y.
Falk, Volkmar
Kempfert, Jörg
Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI
title Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI
title_full Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI
title_fullStr Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI
title_full_unstemmed Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI
title_short Reliability and Influence on Decision Making of fully-automated vs. semi-automated Software Packages for Procedural Planning in TAVI
title_sort reliability and influence on decision making of fully-automated vs. semi-automated software packages for procedural planning in tavi
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7329903/
https://www.ncbi.nlm.nih.gov/pubmed/32612266
http://dx.doi.org/10.1038/s41598-020-67111-5
work_keys_str_mv AT meyeralexander reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT koflermarkus reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT montagnermatteo reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT unbehaunaxel reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT sundermannsimon reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT buzsemih reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT kleinchristoph reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT stammchristof reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT solowjowanatalia reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT emmertmaximiliany reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT falkvolkmar reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi
AT kempfertjorg reliabilityandinfluenceondecisionmakingoffullyautomatedvssemiautomatedsoftwarepackagesforproceduralplanningintavi