Cargando…

Endovascular aortic repairs combined with looping-chimney technique for repairing aortic arch lesions and reconstructing left common carotid artery

BACKGROUND: The aim of this retrospective study was to evaluate the feasibility and efficacy of thoracic endovascular aortic repairs (TEVAR) combined with looping chimney technique (LCT) for repairing aortic arch lesions and reconstructing left common carotid artery. METHODS: Total of 14 patients (m...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Jinhui, Liu, Xunqiang, Tian, Min, Chen, Huanjun, Wang, Jifeng, Ji, Min, Cong, Lei, Yang, Chunxin, Zhu, Enshuai, Tan, Jing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7330391/
https://www.ncbi.nlm.nih.gov/pubmed/32642132
http://dx.doi.org/10.21037/jtd.2020.04.31
_version_ 1783553111343759360
author Zhang, Jinhui
Liu, Xunqiang
Tian, Min
Chen, Huanjun
Wang, Jifeng
Ji, Min
Cong, Lei
Yang, Chunxin
Zhu, Enshuai
Tan, Jing
author_facet Zhang, Jinhui
Liu, Xunqiang
Tian, Min
Chen, Huanjun
Wang, Jifeng
Ji, Min
Cong, Lei
Yang, Chunxin
Zhu, Enshuai
Tan, Jing
author_sort Zhang, Jinhui
collection PubMed
description BACKGROUND: The aim of this retrospective study was to evaluate the feasibility and efficacy of thoracic endovascular aortic repairs (TEVAR) combined with looping chimney technique (LCT) for repairing aortic arch lesions and reconstructing left common carotid artery. METHODS: Total of 14 patients (mean age 52.86±14.46 years; range, 27–79; 10 men, 4 women) were included in the study from December 2016 to December 2018. Aortic arch pathologies of all patients with insufficient proximal landing zone (PLZ) were repaired by TEVAR under local anesthesia, before TEVAR, the left common carotid artery (LCCA) was protected by the guiding sheath from the retrograde brachial access, after aortic stent graft deployed, chimney graft was implanted to restore LCCA by LCT if necessary. All patients underwent computed tomography angiograph (CTA) 2 weeks, 3 months, 6 months and 1 year after surgery. RESULTS: Pathology results of 14 patients included: type B aortic dissection (n=8), penetrating aortic ulcers (n=1), retrograde type A aortic dissection (n=1), thoracic aortic aneurysm (TAA) (n=2), and thoracic aortic pseudoaneurysm (n=2). In all patients, aortic arch lesions were repaired by TEVAR; while LCCA were successfully reconstructed by the LCT. In one case, the innominate artery (IA) was simultaneously reconstructed through the same percutaneous right brachial artery (RBA) access. Coiling eliminated type Ia endoleak in 3 patients, and type II endoleak vanished by plugging left subclavian artery (LSA) in 2 patients. In four patients, the chimney stent (CG) of LCCA was partially compressed and then another bare stent was implanted to restore patency rate. The mean follow-up duration was 9.77±6.64 months (range, 0–24) and no combinations were observed in 13 patients; except in one patient who died of cerebral hemorrhage due to abnormal coagulation function. CONCLUSIONS: TEVAR combined with LCT has shown to be suitable surgical approach for aortic arch lesions. Either covered intentionally or inadvertently, the LCCA could be safely and effectively reconstructed via percutaneous RBA access. Short-term follow-up demonstrated satisfactory morbidity and mortality in high-risk patients; however, longer follow-up is required to assess the effectiveness and durability of this innovative endovascular procedure.
format Online
Article
Text
id pubmed-7330391
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-73303912020-07-07 Endovascular aortic repairs combined with looping-chimney technique for repairing aortic arch lesions and reconstructing left common carotid artery Zhang, Jinhui Liu, Xunqiang Tian, Min Chen, Huanjun Wang, Jifeng Ji, Min Cong, Lei Yang, Chunxin Zhu, Enshuai Tan, Jing J Thorac Dis Original Article BACKGROUND: The aim of this retrospective study was to evaluate the feasibility and efficacy of thoracic endovascular aortic repairs (TEVAR) combined with looping chimney technique (LCT) for repairing aortic arch lesions and reconstructing left common carotid artery. METHODS: Total of 14 patients (mean age 52.86±14.46 years; range, 27–79; 10 men, 4 women) were included in the study from December 2016 to December 2018. Aortic arch pathologies of all patients with insufficient proximal landing zone (PLZ) were repaired by TEVAR under local anesthesia, before TEVAR, the left common carotid artery (LCCA) was protected by the guiding sheath from the retrograde brachial access, after aortic stent graft deployed, chimney graft was implanted to restore LCCA by LCT if necessary. All patients underwent computed tomography angiograph (CTA) 2 weeks, 3 months, 6 months and 1 year after surgery. RESULTS: Pathology results of 14 patients included: type B aortic dissection (n=8), penetrating aortic ulcers (n=1), retrograde type A aortic dissection (n=1), thoracic aortic aneurysm (TAA) (n=2), and thoracic aortic pseudoaneurysm (n=2). In all patients, aortic arch lesions were repaired by TEVAR; while LCCA were successfully reconstructed by the LCT. In one case, the innominate artery (IA) was simultaneously reconstructed through the same percutaneous right brachial artery (RBA) access. Coiling eliminated type Ia endoleak in 3 patients, and type II endoleak vanished by plugging left subclavian artery (LSA) in 2 patients. In four patients, the chimney stent (CG) of LCCA was partially compressed and then another bare stent was implanted to restore patency rate. The mean follow-up duration was 9.77±6.64 months (range, 0–24) and no combinations were observed in 13 patients; except in one patient who died of cerebral hemorrhage due to abnormal coagulation function. CONCLUSIONS: TEVAR combined with LCT has shown to be suitable surgical approach for aortic arch lesions. Either covered intentionally or inadvertently, the LCCA could be safely and effectively reconstructed via percutaneous RBA access. Short-term follow-up demonstrated satisfactory morbidity and mortality in high-risk patients; however, longer follow-up is required to assess the effectiveness and durability of this innovative endovascular procedure. AME Publishing Company 2020-05 /pmc/articles/PMC7330391/ /pubmed/32642132 http://dx.doi.org/10.21037/jtd.2020.04.31 Text en 2020 Journal of Thoracic Disease. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Zhang, Jinhui
Liu, Xunqiang
Tian, Min
Chen, Huanjun
Wang, Jifeng
Ji, Min
Cong, Lei
Yang, Chunxin
Zhu, Enshuai
Tan, Jing
Endovascular aortic repairs combined with looping-chimney technique for repairing aortic arch lesions and reconstructing left common carotid artery
title Endovascular aortic repairs combined with looping-chimney technique for repairing aortic arch lesions and reconstructing left common carotid artery
title_full Endovascular aortic repairs combined with looping-chimney technique for repairing aortic arch lesions and reconstructing left common carotid artery
title_fullStr Endovascular aortic repairs combined with looping-chimney technique for repairing aortic arch lesions and reconstructing left common carotid artery
title_full_unstemmed Endovascular aortic repairs combined with looping-chimney technique for repairing aortic arch lesions and reconstructing left common carotid artery
title_short Endovascular aortic repairs combined with looping-chimney technique for repairing aortic arch lesions and reconstructing left common carotid artery
title_sort endovascular aortic repairs combined with looping-chimney technique for repairing aortic arch lesions and reconstructing left common carotid artery
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7330391/
https://www.ncbi.nlm.nih.gov/pubmed/32642132
http://dx.doi.org/10.21037/jtd.2020.04.31
work_keys_str_mv AT zhangjinhui endovascularaorticrepairscombinedwithloopingchimneytechniqueforrepairingaorticarchlesionsandreconstructingleftcommoncarotidartery
AT liuxunqiang endovascularaorticrepairscombinedwithloopingchimneytechniqueforrepairingaorticarchlesionsandreconstructingleftcommoncarotidartery
AT tianmin endovascularaorticrepairscombinedwithloopingchimneytechniqueforrepairingaorticarchlesionsandreconstructingleftcommoncarotidartery
AT chenhuanjun endovascularaorticrepairscombinedwithloopingchimneytechniqueforrepairingaorticarchlesionsandreconstructingleftcommoncarotidartery
AT wangjifeng endovascularaorticrepairscombinedwithloopingchimneytechniqueforrepairingaorticarchlesionsandreconstructingleftcommoncarotidartery
AT jimin endovascularaorticrepairscombinedwithloopingchimneytechniqueforrepairingaorticarchlesionsandreconstructingleftcommoncarotidartery
AT conglei endovascularaorticrepairscombinedwithloopingchimneytechniqueforrepairingaorticarchlesionsandreconstructingleftcommoncarotidartery
AT yangchunxin endovascularaorticrepairscombinedwithloopingchimneytechniqueforrepairingaorticarchlesionsandreconstructingleftcommoncarotidartery
AT zhuenshuai endovascularaorticrepairscombinedwithloopingchimneytechniqueforrepairingaorticarchlesionsandreconstructingleftcommoncarotidartery
AT tanjing endovascularaorticrepairscombinedwithloopingchimneytechniqueforrepairingaorticarchlesionsandreconstructingleftcommoncarotidartery