Cargando…
Usefulness of four-limb blood pressure measurement in prediction of overall and cardiovascular mortality in acute myocardial infarction
Four-limb blood pressure measurement could improve mortality prediction in the elderly. However, there was no study to evaluate whether such measurement was still useful in predicting overall and cardiovascular (CV) mortality in acute myocardial infarction (AMI). Two hundred AMI patients admitted to...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Ivyspring International Publisher
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7330671/ https://www.ncbi.nlm.nih.gov/pubmed/32624684 http://dx.doi.org/10.7150/ijms.44735 |
_version_ | 1783553168306601984 |
---|---|
author | Hsu, Po-Chao Lee, Wen-Hsien Tsai, Wei-Chung Chu, Chun-Yuan Lee, Chee-Siong Yen, Hsueh-Wei Lin, Tsung-Hsien Voon, Wen-Chol Lai, Wen-Ter Sheu, Sheng-Hsiung Su, Ho-Ming |
author_facet | Hsu, Po-Chao Lee, Wen-Hsien Tsai, Wei-Chung Chu, Chun-Yuan Lee, Chee-Siong Yen, Hsueh-Wei Lin, Tsung-Hsien Voon, Wen-Chol Lai, Wen-Ter Sheu, Sheng-Hsiung Su, Ho-Ming |
author_sort | Hsu, Po-Chao |
collection | PubMed |
description | Four-limb blood pressure measurement could improve mortality prediction in the elderly. However, there was no study to evaluate whether such measurement was still useful in predicting overall and cardiovascular (CV) mortality in acute myocardial infarction (AMI). Two hundred AMI patients admitted to cardiac care unit were enrolled. The 4-limb blood pressures, inter-limb blood pressure differences, and ankle brachial index (ABI) were measured using an ABI-form device. The median follow-up to mortality was 64 months (25th-75th percentile: 5-174 months). There were 40 and 138 patients documented as CV and overall mortality, respectively. After multivariable adjustment, the ankle diastolic blood pressure (DBP) on the lower side, ABI value, ABI < 0.9, interarm DBP difference, interankle systolic blood pressure (SBP) and DBP differences, interankle SBP difference ≥ 15 mmHg, and interankle DBP difference ≥ 10 mmHg could predict overall mortality (P ≤ 0.025). The ankle DBP on the lower side, interankle DBP difference, and interankle DBP difference ≥ 10 mmHg could predict CV mortality (P ≤ 0.031). In addition, in the Nested Cox model, the model including the ankle DBP on the lower side and the model including interankle DBP difference had the best value for overall and CV mortality prediction, respectively (P ≤ 0.031). In AMI patients, 4-limb blood pressure measurement could generate several useful parameters in predicting overall and CV mortality. Furthermore, ankle DBP on the lower side and interankle DBP difference were the most powerful parameters in prediction of overall and CV mortality, respectively. |
format | Online Article Text |
id | pubmed-7330671 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Ivyspring International Publisher |
record_format | MEDLINE/PubMed |
spelling | pubmed-73306712020-07-02 Usefulness of four-limb blood pressure measurement in prediction of overall and cardiovascular mortality in acute myocardial infarction Hsu, Po-Chao Lee, Wen-Hsien Tsai, Wei-Chung Chu, Chun-Yuan Lee, Chee-Siong Yen, Hsueh-Wei Lin, Tsung-Hsien Voon, Wen-Chol Lai, Wen-Ter Sheu, Sheng-Hsiung Su, Ho-Ming Int J Med Sci Research Paper Four-limb blood pressure measurement could improve mortality prediction in the elderly. However, there was no study to evaluate whether such measurement was still useful in predicting overall and cardiovascular (CV) mortality in acute myocardial infarction (AMI). Two hundred AMI patients admitted to cardiac care unit were enrolled. The 4-limb blood pressures, inter-limb blood pressure differences, and ankle brachial index (ABI) were measured using an ABI-form device. The median follow-up to mortality was 64 months (25th-75th percentile: 5-174 months). There were 40 and 138 patients documented as CV and overall mortality, respectively. After multivariable adjustment, the ankle diastolic blood pressure (DBP) on the lower side, ABI value, ABI < 0.9, interarm DBP difference, interankle systolic blood pressure (SBP) and DBP differences, interankle SBP difference ≥ 15 mmHg, and interankle DBP difference ≥ 10 mmHg could predict overall mortality (P ≤ 0.025). The ankle DBP on the lower side, interankle DBP difference, and interankle DBP difference ≥ 10 mmHg could predict CV mortality (P ≤ 0.031). In addition, in the Nested Cox model, the model including the ankle DBP on the lower side and the model including interankle DBP difference had the best value for overall and CV mortality prediction, respectively (P ≤ 0.031). In AMI patients, 4-limb blood pressure measurement could generate several useful parameters in predicting overall and CV mortality. Furthermore, ankle DBP on the lower side and interankle DBP difference were the most powerful parameters in prediction of overall and CV mortality, respectively. Ivyspring International Publisher 2020-05-23 /pmc/articles/PMC7330671/ /pubmed/32624684 http://dx.doi.org/10.7150/ijms.44735 Text en © The author(s) This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/). See http://ivyspring.com/terms for full terms and conditions. |
spellingShingle | Research Paper Hsu, Po-Chao Lee, Wen-Hsien Tsai, Wei-Chung Chu, Chun-Yuan Lee, Chee-Siong Yen, Hsueh-Wei Lin, Tsung-Hsien Voon, Wen-Chol Lai, Wen-Ter Sheu, Sheng-Hsiung Su, Ho-Ming Usefulness of four-limb blood pressure measurement in prediction of overall and cardiovascular mortality in acute myocardial infarction |
title | Usefulness of four-limb blood pressure measurement in prediction of overall and cardiovascular mortality in acute myocardial infarction |
title_full | Usefulness of four-limb blood pressure measurement in prediction of overall and cardiovascular mortality in acute myocardial infarction |
title_fullStr | Usefulness of four-limb blood pressure measurement in prediction of overall and cardiovascular mortality in acute myocardial infarction |
title_full_unstemmed | Usefulness of four-limb blood pressure measurement in prediction of overall and cardiovascular mortality in acute myocardial infarction |
title_short | Usefulness of four-limb blood pressure measurement in prediction of overall and cardiovascular mortality in acute myocardial infarction |
title_sort | usefulness of four-limb blood pressure measurement in prediction of overall and cardiovascular mortality in acute myocardial infarction |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7330671/ https://www.ncbi.nlm.nih.gov/pubmed/32624684 http://dx.doi.org/10.7150/ijms.44735 |
work_keys_str_mv | AT hsupochao usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction AT leewenhsien usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction AT tsaiweichung usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction AT chuchunyuan usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction AT leecheesiong usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction AT yenhsuehwei usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction AT lintsunghsien usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction AT voonwenchol usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction AT laiwenter usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction AT sheushenghsiung usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction AT suhoming usefulnessoffourlimbbloodpressuremeasurementinpredictionofoverallandcardiovascularmortalityinacutemyocardialinfarction |