Cargando…
Comparison of magnetic resonance imaging and computed tomography to measure preoperative parameters of children with pectus excavatum
IMPORTANCE: Pectus excavatum (PE) is the most common thoracic wall deformity in children, we need a method which could be used to evaluate pulmonary functions and effects on development. OBJECTIVE: To evaluate the use of 3D T1‐weighted (3DT1) and mDIXON magnetic resonance imaging (MRI) sequences for...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7331316/ https://www.ncbi.nlm.nih.gov/pubmed/32851300 http://dx.doi.org/10.1002/ped4.12132 |
_version_ | 1783553302151036928 |
---|---|
author | Sun, Jihang Chen, Chenghao Peng, Yun Zhang, Yue Tian, Hongwei Yu, Jie Cao, Jun Zeng, Qi |
author_facet | Sun, Jihang Chen, Chenghao Peng, Yun Zhang, Yue Tian, Hongwei Yu, Jie Cao, Jun Zeng, Qi |
author_sort | Sun, Jihang |
collection | PubMed |
description | IMPORTANCE: Pectus excavatum (PE) is the most common thoracic wall deformity in children, we need a method which could be used to evaluate pulmonary functions and effects on development. OBJECTIVE: To evaluate the use of 3D T1‐weighted (3DT1) and mDIXON magnetic resonance imaging (MRI) sequences for measuring the thoracic parameters and morphology of children with PE, comparing the measurements with those made on computed tomography (CT). METHODS: This is a retrospective study of children with thoracic deformities who were hospitalized at the Department of Thoracic Surgery of the Heart Center, Beijing Children's Hospital, between June 2014 and June 2015. Chest CT was performed first, with the MRI scanning then being performed 0–3 days later. The mDIXON sequences were obtained in inspiratory and expiratory phases and the 3DT1 sequences were obtained during free breathing. Thoracic volume was measured using the acquired images. RESULTS: The lung volumes measured on mDIXON MRI and CT were highly correlated, with the Haller index not being significantly different between the two methods. Bland‐Altman analyses showed that lung, cardiac, and retrosternal parameters were similar between the two methods. Pulmonary parameters were higher with the end‐inspiratory phase mDIXON images than with the end‐expiratory phase images, as expected, while cardiac parameters were unaffected by the respiratory phase. INTERPRETATION: Thoracic volumes measured on mDIXON MRI in combination with held respiration could reflect lung volume functions and help in observing the movement functions of the lungs and heart. The method could be used instead of CT, avoiding subjecting the patient to potentially harmful radiation. |
format | Online Article Text |
id | pubmed-7331316 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-73313162020-08-25 Comparison of magnetic resonance imaging and computed tomography to measure preoperative parameters of children with pectus excavatum Sun, Jihang Chen, Chenghao Peng, Yun Zhang, Yue Tian, Hongwei Yu, Jie Cao, Jun Zeng, Qi Pediatr Investig Original Articles IMPORTANCE: Pectus excavatum (PE) is the most common thoracic wall deformity in children, we need a method which could be used to evaluate pulmonary functions and effects on development. OBJECTIVE: To evaluate the use of 3D T1‐weighted (3DT1) and mDIXON magnetic resonance imaging (MRI) sequences for measuring the thoracic parameters and morphology of children with PE, comparing the measurements with those made on computed tomography (CT). METHODS: This is a retrospective study of children with thoracic deformities who were hospitalized at the Department of Thoracic Surgery of the Heart Center, Beijing Children's Hospital, between June 2014 and June 2015. Chest CT was performed first, with the MRI scanning then being performed 0–3 days later. The mDIXON sequences were obtained in inspiratory and expiratory phases and the 3DT1 sequences were obtained during free breathing. Thoracic volume was measured using the acquired images. RESULTS: The lung volumes measured on mDIXON MRI and CT were highly correlated, with the Haller index not being significantly different between the two methods. Bland‐Altman analyses showed that lung, cardiac, and retrosternal parameters were similar between the two methods. Pulmonary parameters were higher with the end‐inspiratory phase mDIXON images than with the end‐expiratory phase images, as expected, while cardiac parameters were unaffected by the respiratory phase. INTERPRETATION: Thoracic volumes measured on mDIXON MRI in combination with held respiration could reflect lung volume functions and help in observing the movement functions of the lungs and heart. The method could be used instead of CT, avoiding subjecting the patient to potentially harmful radiation. John Wiley and Sons Inc. 2019-06-25 /pmc/articles/PMC7331316/ /pubmed/32851300 http://dx.doi.org/10.1002/ped4.12132 Text en © 2019 Chinese Medical Association. Pediatric Investigation published by John Wiley & Sons Australia, Ltd on behalf of Futang Research Center of Pediatric Development. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Articles Sun, Jihang Chen, Chenghao Peng, Yun Zhang, Yue Tian, Hongwei Yu, Jie Cao, Jun Zeng, Qi Comparison of magnetic resonance imaging and computed tomography to measure preoperative parameters of children with pectus excavatum |
title | Comparison of magnetic resonance imaging and computed tomography to measure preoperative parameters of children with pectus excavatum |
title_full | Comparison of magnetic resonance imaging and computed tomography to measure preoperative parameters of children with pectus excavatum |
title_fullStr | Comparison of magnetic resonance imaging and computed tomography to measure preoperative parameters of children with pectus excavatum |
title_full_unstemmed | Comparison of magnetic resonance imaging and computed tomography to measure preoperative parameters of children with pectus excavatum |
title_short | Comparison of magnetic resonance imaging and computed tomography to measure preoperative parameters of children with pectus excavatum |
title_sort | comparison of magnetic resonance imaging and computed tomography to measure preoperative parameters of children with pectus excavatum |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7331316/ https://www.ncbi.nlm.nih.gov/pubmed/32851300 http://dx.doi.org/10.1002/ped4.12132 |
work_keys_str_mv | AT sunjihang comparisonofmagneticresonanceimagingandcomputedtomographytomeasurepreoperativeparametersofchildrenwithpectusexcavatum AT chenchenghao comparisonofmagneticresonanceimagingandcomputedtomographytomeasurepreoperativeparametersofchildrenwithpectusexcavatum AT pengyun comparisonofmagneticresonanceimagingandcomputedtomographytomeasurepreoperativeparametersofchildrenwithpectusexcavatum AT zhangyue comparisonofmagneticresonanceimagingandcomputedtomographytomeasurepreoperativeparametersofchildrenwithpectusexcavatum AT tianhongwei comparisonofmagneticresonanceimagingandcomputedtomographytomeasurepreoperativeparametersofchildrenwithpectusexcavatum AT yujie comparisonofmagneticresonanceimagingandcomputedtomographytomeasurepreoperativeparametersofchildrenwithpectusexcavatum AT caojun comparisonofmagneticresonanceimagingandcomputedtomographytomeasurepreoperativeparametersofchildrenwithpectusexcavatum AT zengqi comparisonofmagneticresonanceimagingandcomputedtomographytomeasurepreoperativeparametersofchildrenwithpectusexcavatum |