Cargando…
Optimum concentration of iodine contrast agent injection for best stent visualization using Neuroform Atlas stent during stent-assisted coil embolization: Case reviews based on in vitro experiments
BACKGROUND: The present study aimed to evaluate the influence of contrast agent concentration (Conc) on the visibility of Neuroform Atlas in vitro and in clinical cases. METHODS: A plastic tube was filled with several Conc. in saline (experiment 1) and blood (experiment 2). Thereafter, the Neuroform...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Scientific Scholar
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7332700/ https://www.ncbi.nlm.nih.gov/pubmed/32637223 http://dx.doi.org/10.25259/SNI_239_2020 |
_version_ | 1783553575410991104 |
---|---|
author | Aketa, Shuta Wajima, Daisuke Kiyomoto, Masayoshi Izumi, Natsuhiko Yonezawa, Taiji |
author_facet | Aketa, Shuta Wajima, Daisuke Kiyomoto, Masayoshi Izumi, Natsuhiko Yonezawa, Taiji |
author_sort | Aketa, Shuta |
collection | PubMed |
description | BACKGROUND: The present study aimed to evaluate the influence of contrast agent concentration (Conc) on the visibility of Neuroform Atlas in vitro and in clinical cases. METHODS: A plastic tube was filled with several Conc. in saline (experiment 1) and blood (experiment 2). Thereafter, the Neuroform Atlas was placed around the plastic tube in an acrylic shield case. In experiment 3, the Neuroform Atlas was placed in the internal carotid artery of the endo vascular evaluator endovascular training system with an injection of several Conc in saline. Five slices of the axial images obtained using the 3D-cone-beam computed tomography (3D-CBCT) with the digital subtraction angiography system were evaluated. A 1-cm(2) circular center, which showed the contrast agent in saline or blood, was determined as the region of interest, and its pixels were evaluated. RESULTS: Radiation density (Rd) was directly proportional to the contrast agent in saline and blood (experiment 1: (Rd (pixel)) = 6.8495 × (concentration (%)) + 152.72 (R(2) = 0.99), experiment 2: (Rd (pixel)) = 6.2485 × (concentration (%)) + 167.42 (R(2) = 0.9966), experiment 3: (Rd (pixel)) = 10.287 × (concentration (%)) + 108.26 (R(2) = 0.993)]. Rd calculated similarly in our cases (concentration varied from 5% to 8%) was between the range of “Rd of experiment 2” and “Rd of experiment 3.” CONCLUSION: Based on our in vitro experiments, with 5–8% concentration, Neuroform Atlas stent deployment with complete neck coverage by the bulging stent and wall apposition was visualized on 3D-CBCT. |
format | Online Article Text |
id | pubmed-7332700 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Scientific Scholar |
record_format | MEDLINE/PubMed |
spelling | pubmed-73327002020-07-06 Optimum concentration of iodine contrast agent injection for best stent visualization using Neuroform Atlas stent during stent-assisted coil embolization: Case reviews based on in vitro experiments Aketa, Shuta Wajima, Daisuke Kiyomoto, Masayoshi Izumi, Natsuhiko Yonezawa, Taiji Surg Neurol Int Original Article BACKGROUND: The present study aimed to evaluate the influence of contrast agent concentration (Conc) on the visibility of Neuroform Atlas in vitro and in clinical cases. METHODS: A plastic tube was filled with several Conc. in saline (experiment 1) and blood (experiment 2). Thereafter, the Neuroform Atlas was placed around the plastic tube in an acrylic shield case. In experiment 3, the Neuroform Atlas was placed in the internal carotid artery of the endo vascular evaluator endovascular training system with an injection of several Conc in saline. Five slices of the axial images obtained using the 3D-cone-beam computed tomography (3D-CBCT) with the digital subtraction angiography system were evaluated. A 1-cm(2) circular center, which showed the contrast agent in saline or blood, was determined as the region of interest, and its pixels were evaluated. RESULTS: Radiation density (Rd) was directly proportional to the contrast agent in saline and blood (experiment 1: (Rd (pixel)) = 6.8495 × (concentration (%)) + 152.72 (R(2) = 0.99), experiment 2: (Rd (pixel)) = 6.2485 × (concentration (%)) + 167.42 (R(2) = 0.9966), experiment 3: (Rd (pixel)) = 10.287 × (concentration (%)) + 108.26 (R(2) = 0.993)]. Rd calculated similarly in our cases (concentration varied from 5% to 8%) was between the range of “Rd of experiment 2” and “Rd of experiment 3.” CONCLUSION: Based on our in vitro experiments, with 5–8% concentration, Neuroform Atlas stent deployment with complete neck coverage by the bulging stent and wall apposition was visualized on 3D-CBCT. Scientific Scholar 2020-06-27 /pmc/articles/PMC7332700/ /pubmed/32637223 http://dx.doi.org/10.25259/SNI_239_2020 Text en Copyright: © 2020 Surgical Neurology International http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Aketa, Shuta Wajima, Daisuke Kiyomoto, Masayoshi Izumi, Natsuhiko Yonezawa, Taiji Optimum concentration of iodine contrast agent injection for best stent visualization using Neuroform Atlas stent during stent-assisted coil embolization: Case reviews based on in vitro experiments |
title | Optimum concentration of iodine contrast agent injection for best stent visualization using Neuroform Atlas stent during stent-assisted coil embolization: Case reviews based on in vitro experiments |
title_full | Optimum concentration of iodine contrast agent injection for best stent visualization using Neuroform Atlas stent during stent-assisted coil embolization: Case reviews based on in vitro experiments |
title_fullStr | Optimum concentration of iodine contrast agent injection for best stent visualization using Neuroform Atlas stent during stent-assisted coil embolization: Case reviews based on in vitro experiments |
title_full_unstemmed | Optimum concentration of iodine contrast agent injection for best stent visualization using Neuroform Atlas stent during stent-assisted coil embolization: Case reviews based on in vitro experiments |
title_short | Optimum concentration of iodine contrast agent injection for best stent visualization using Neuroform Atlas stent during stent-assisted coil embolization: Case reviews based on in vitro experiments |
title_sort | optimum concentration of iodine contrast agent injection for best stent visualization using neuroform atlas stent during stent-assisted coil embolization: case reviews based on in vitro experiments |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7332700/ https://www.ncbi.nlm.nih.gov/pubmed/32637223 http://dx.doi.org/10.25259/SNI_239_2020 |
work_keys_str_mv | AT aketashuta optimumconcentrationofiodinecontrastagentinjectionforbeststentvisualizationusingneuroformatlasstentduringstentassistedcoilembolizationcasereviewsbasedoninvitroexperiments AT wajimadaisuke optimumconcentrationofiodinecontrastagentinjectionforbeststentvisualizationusingneuroformatlasstentduringstentassistedcoilembolizationcasereviewsbasedoninvitroexperiments AT kiyomotomasayoshi optimumconcentrationofiodinecontrastagentinjectionforbeststentvisualizationusingneuroformatlasstentduringstentassistedcoilembolizationcasereviewsbasedoninvitroexperiments AT izuminatsuhiko optimumconcentrationofiodinecontrastagentinjectionforbeststentvisualizationusingneuroformatlasstentduringstentassistedcoilembolizationcasereviewsbasedoninvitroexperiments AT yonezawataiji optimumconcentrationofiodinecontrastagentinjectionforbeststentvisualizationusingneuroformatlasstentduringstentassistedcoilembolizationcasereviewsbasedoninvitroexperiments |