Cargando…
Rapid pulmonary vein isolation utilizing the third-generation laserballoon – The PhoeniX registry
BACKGROUND: Balloon-based ablation systems for pulmonary vein isolation (PVI) are providing procedural safety and efficacy as well as favourable clinical outcome. Although second-generation laser balloon (LB2) based PVI has been shown safety and efficacy relatively long procedural duration was a str...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7334810/ https://www.ncbi.nlm.nih.gov/pubmed/32642555 http://dx.doi.org/10.1016/j.ijcha.2020.100576 |
_version_ | 1783554011741290496 |
---|---|
author | Heeger, Christian-H. Tiemeyer, Christian M. Phan, Huong-Lan Meyer-Saraei, Roza Fink, Thomas Sciacca, Vanessa Liosis, Spyridon Brüggemann, Ben Große, Niels Fahimi, Bezhad Reincke, Samuel Kuck, Karl-Heinz Ouyang, Feifan Vogler, Julia Eitel, Charlotte Tilz, Roland R. |
author_facet | Heeger, Christian-H. Tiemeyer, Christian M. Phan, Huong-Lan Meyer-Saraei, Roza Fink, Thomas Sciacca, Vanessa Liosis, Spyridon Brüggemann, Ben Große, Niels Fahimi, Bezhad Reincke, Samuel Kuck, Karl-Heinz Ouyang, Feifan Vogler, Julia Eitel, Charlotte Tilz, Roland R. |
author_sort | Heeger, Christian-H. |
collection | PubMed |
description | BACKGROUND: Balloon-based ablation systems for pulmonary vein isolation (PVI) are providing procedural safety and efficacy as well as favourable clinical outcome. Although second-generation laser balloon (LB2) based PVI has been shown safety and efficacy relatively long procedural duration was a strong limitation. The third-generation laser balloon (LB3) offers and automized ablation for rapid PVI. We determined safety, efficacy and procedural characteristics of this new promising ablation system. METHODS AND RESULTS: A total of 15 consecutive patients were prospectively enrolled. All patients underwent PVI using the LB3. A total 59/59 PVs (100%) were successfully isolated. Procedural data was compared to the last 15 consecutive patients treated by the LB2. The median procedure time significantly declined from LB2 (91 (86, 105) min) to LB3 (77 (68, 87) min), p < 0.001. Similarly, the median left atrial dwelling time significantly decreased from LB2 (72 (62, 84) min) to LB3 (45 (38, 52) min), p < 0.0001. The total laser time decreased from LB2 (1920 (1765, 2193) sec) to LB3 (1077 (896, 1165) sec), p < 0.00001. A pure single shot PVI was performed in 18/59 PVs (31%). For major adverse events no differences were detected between the groups (LB2 1/15 (6.7%) and LB3 1/15 (6.7%), p = 0.999). CONCLUSION: The LB3 was safe and effective for PVI. Procedure time, LA dwelling time and total laser time significantly decreased compared to LB2. |
format | Online Article Text |
id | pubmed-7334810 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-73348102020-07-07 Rapid pulmonary vein isolation utilizing the third-generation laserballoon – The PhoeniX registry Heeger, Christian-H. Tiemeyer, Christian M. Phan, Huong-Lan Meyer-Saraei, Roza Fink, Thomas Sciacca, Vanessa Liosis, Spyridon Brüggemann, Ben Große, Niels Fahimi, Bezhad Reincke, Samuel Kuck, Karl-Heinz Ouyang, Feifan Vogler, Julia Eitel, Charlotte Tilz, Roland R. Int J Cardiol Heart Vasc Original Paper BACKGROUND: Balloon-based ablation systems for pulmonary vein isolation (PVI) are providing procedural safety and efficacy as well as favourable clinical outcome. Although second-generation laser balloon (LB2) based PVI has been shown safety and efficacy relatively long procedural duration was a strong limitation. The third-generation laser balloon (LB3) offers and automized ablation for rapid PVI. We determined safety, efficacy and procedural characteristics of this new promising ablation system. METHODS AND RESULTS: A total of 15 consecutive patients were prospectively enrolled. All patients underwent PVI using the LB3. A total 59/59 PVs (100%) were successfully isolated. Procedural data was compared to the last 15 consecutive patients treated by the LB2. The median procedure time significantly declined from LB2 (91 (86, 105) min) to LB3 (77 (68, 87) min), p < 0.001. Similarly, the median left atrial dwelling time significantly decreased from LB2 (72 (62, 84) min) to LB3 (45 (38, 52) min), p < 0.0001. The total laser time decreased from LB2 (1920 (1765, 2193) sec) to LB3 (1077 (896, 1165) sec), p < 0.00001. A pure single shot PVI was performed in 18/59 PVs (31%). For major adverse events no differences were detected between the groups (LB2 1/15 (6.7%) and LB3 1/15 (6.7%), p = 0.999). CONCLUSION: The LB3 was safe and effective for PVI. Procedure time, LA dwelling time and total laser time significantly decreased compared to LB2. Elsevier 2020-07-03 /pmc/articles/PMC7334810/ /pubmed/32642555 http://dx.doi.org/10.1016/j.ijcha.2020.100576 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Paper Heeger, Christian-H. Tiemeyer, Christian M. Phan, Huong-Lan Meyer-Saraei, Roza Fink, Thomas Sciacca, Vanessa Liosis, Spyridon Brüggemann, Ben Große, Niels Fahimi, Bezhad Reincke, Samuel Kuck, Karl-Heinz Ouyang, Feifan Vogler, Julia Eitel, Charlotte Tilz, Roland R. Rapid pulmonary vein isolation utilizing the third-generation laserballoon – The PhoeniX registry |
title | Rapid pulmonary vein isolation utilizing the third-generation laserballoon – The PhoeniX registry |
title_full | Rapid pulmonary vein isolation utilizing the third-generation laserballoon – The PhoeniX registry |
title_fullStr | Rapid pulmonary vein isolation utilizing the third-generation laserballoon – The PhoeniX registry |
title_full_unstemmed | Rapid pulmonary vein isolation utilizing the third-generation laserballoon – The PhoeniX registry |
title_short | Rapid pulmonary vein isolation utilizing the third-generation laserballoon – The PhoeniX registry |
title_sort | rapid pulmonary vein isolation utilizing the third-generation laserballoon – the phoenix registry |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7334810/ https://www.ncbi.nlm.nih.gov/pubmed/32642555 http://dx.doi.org/10.1016/j.ijcha.2020.100576 |
work_keys_str_mv | AT heegerchristianh rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT tiemeyerchristianm rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT phanhuonglan rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT meyersaraeiroza rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT finkthomas rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT sciaccavanessa rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT liosisspyridon rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT bruggemannben rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT großeniels rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT fahimibezhad rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT reinckesamuel rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT kuckkarlheinz rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT ouyangfeifan rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT voglerjulia rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT eitelcharlotte rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry AT tilzrolandr rapidpulmonaryveinisolationutilizingthethirdgenerationlaserballoonthephoenixregistry |