Validity of traditional physical activity intensity calibration methods and the feasibility of self-paced walking and running on individualised calibration of physical activity intensity in children
There are no practical and valid methods for the assessment of individualised physical activity (PA) intensity in observational studies. Therefore, we investigated the validity of commonly used metabolic equivalent of tasks (METs) and pre-determined PA intensity classification methods against indivi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7335054/ https://www.ncbi.nlm.nih.gov/pubmed/32620888 http://dx.doi.org/10.1038/s41598-020-67983-7 |
_version_ | 1783554059195645952 |
---|---|
author | Haapala, Eero A. Gao, Ying Vanhala, Anssi Rantalainen, Timo Finni, Taija |
author_facet | Haapala, Eero A. Gao, Ying Vanhala, Anssi Rantalainen, Timo Finni, Taija |
author_sort | Haapala, Eero A. |
collection | PubMed |
description | There are no practical and valid methods for the assessment of individualised physical activity (PA) intensity in observational studies. Therefore, we investigated the validity of commonly used metabolic equivalent of tasks (METs) and pre-determined PA intensity classification methods against individualised PA intensity classification in 35 children 7–11-years-of-age. Then, we studied validity of mean amplitude deviation (MAD) measured by accelerometry during self-paced walking and running in assessment of individualised PA intensity. Individualised moderate PA (MPA) was defined as V̇O(2) ≥ 40% of V̇O(2reserve) and V̇O(2) < ventilatory threshold (VT) and vigorous PA (VPA) as V̇O(2) ≥ VT. We classified > 3–6 (or alternatively > 4–7) METs as MPA and > 6 (> 7) METs as VPA. Task intensities were classified according to previous calibration studies. MET-categories correctly identified 25.9–83.3% of light PA, 85.9–90.3% of MPA, and 56.7–82.2% of VPA. Task-specific categories correctly classified 53.7% of light PA, 90.6% of MPA, and 57.8% of VPA. MAD during self-paced walking discriminated MVPA from light PA (sensitivity = 67.4, specificity = 88.0) and MAD during self-paced running discriminated VPA from MPA (sensitivity = 78.8, specificity = 79.3). In conclusion, commonly used methods may misclassify PA intensity in children. MAD during self-paced running may provide a novel and practical method for determining individualised VPA intensity in children. |
format | Online Article Text |
id | pubmed-7335054 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-73350542020-07-07 Validity of traditional physical activity intensity calibration methods and the feasibility of self-paced walking and running on individualised calibration of physical activity intensity in children Haapala, Eero A. Gao, Ying Vanhala, Anssi Rantalainen, Timo Finni, Taija Sci Rep Article There are no practical and valid methods for the assessment of individualised physical activity (PA) intensity in observational studies. Therefore, we investigated the validity of commonly used metabolic equivalent of tasks (METs) and pre-determined PA intensity classification methods against individualised PA intensity classification in 35 children 7–11-years-of-age. Then, we studied validity of mean amplitude deviation (MAD) measured by accelerometry during self-paced walking and running in assessment of individualised PA intensity. Individualised moderate PA (MPA) was defined as V̇O(2) ≥ 40% of V̇O(2reserve) and V̇O(2) < ventilatory threshold (VT) and vigorous PA (VPA) as V̇O(2) ≥ VT. We classified > 3–6 (or alternatively > 4–7) METs as MPA and > 6 (> 7) METs as VPA. Task intensities were classified according to previous calibration studies. MET-categories correctly identified 25.9–83.3% of light PA, 85.9–90.3% of MPA, and 56.7–82.2% of VPA. Task-specific categories correctly classified 53.7% of light PA, 90.6% of MPA, and 57.8% of VPA. MAD during self-paced walking discriminated MVPA from light PA (sensitivity = 67.4, specificity = 88.0) and MAD during self-paced running discriminated VPA from MPA (sensitivity = 78.8, specificity = 79.3). In conclusion, commonly used methods may misclassify PA intensity in children. MAD during self-paced running may provide a novel and practical method for determining individualised VPA intensity in children. Nature Publishing Group UK 2020-07-03 /pmc/articles/PMC7335054/ /pubmed/32620888 http://dx.doi.org/10.1038/s41598-020-67983-7 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Haapala, Eero A. Gao, Ying Vanhala, Anssi Rantalainen, Timo Finni, Taija Validity of traditional physical activity intensity calibration methods and the feasibility of self-paced walking and running on individualised calibration of physical activity intensity in children |
title | Validity of traditional physical activity intensity calibration methods and the feasibility of self-paced walking and running on individualised calibration of physical activity intensity in children |
title_full | Validity of traditional physical activity intensity calibration methods and the feasibility of self-paced walking and running on individualised calibration of physical activity intensity in children |
title_fullStr | Validity of traditional physical activity intensity calibration methods and the feasibility of self-paced walking and running on individualised calibration of physical activity intensity in children |
title_full_unstemmed | Validity of traditional physical activity intensity calibration methods and the feasibility of self-paced walking and running on individualised calibration of physical activity intensity in children |
title_short | Validity of traditional physical activity intensity calibration methods and the feasibility of self-paced walking and running on individualised calibration of physical activity intensity in children |
title_sort | validity of traditional physical activity intensity calibration methods and the feasibility of self-paced walking and running on individualised calibration of physical activity intensity in children |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7335054/ https://www.ncbi.nlm.nih.gov/pubmed/32620888 http://dx.doi.org/10.1038/s41598-020-67983-7 |
work_keys_str_mv | AT haapalaeeroa validityoftraditionalphysicalactivityintensitycalibrationmethodsandthefeasibilityofselfpacedwalkingandrunningonindividualisedcalibrationofphysicalactivityintensityinchildren AT gaoying validityoftraditionalphysicalactivityintensitycalibrationmethodsandthefeasibilityofselfpacedwalkingandrunningonindividualisedcalibrationofphysicalactivityintensityinchildren AT vanhalaanssi validityoftraditionalphysicalactivityintensitycalibrationmethodsandthefeasibilityofselfpacedwalkingandrunningonindividualisedcalibrationofphysicalactivityintensityinchildren AT rantalainentimo validityoftraditionalphysicalactivityintensitycalibrationmethodsandthefeasibilityofselfpacedwalkingandrunningonindividualisedcalibrationofphysicalactivityintensityinchildren AT finnitaija validityoftraditionalphysicalactivityintensitycalibrationmethodsandthefeasibilityofselfpacedwalkingandrunningonindividualisedcalibrationofphysicalactivityintensityinchildren |