Cargando…
Assessment of a Non Invasive Brain Oximeter in Volunteers Undergoing Acute Hypoxia
INTRODUCTION: Research in traumatic brain injury suggests better patient outcomes when invasive oxygen monitoring is used to detect and correct episodes of brain hypoxia. Invasive brain oxygen monitoring is, however, not routinely used due to the risks, costs and technical challengers. We are develo...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7335769/ https://www.ncbi.nlm.nih.gov/pubmed/32669881 http://dx.doi.org/10.2147/MDER.S250102 |
_version_ | 1783554192747528192 |
---|---|
author | Dixon, Barry MacLeod, David B |
author_facet | Dixon, Barry MacLeod, David B |
author_sort | Dixon, Barry |
collection | PubMed |
description | INTRODUCTION: Research in traumatic brain injury suggests better patient outcomes when invasive oxygen monitoring is used to detect and correct episodes of brain hypoxia. Invasive brain oxygen monitoring is, however, not routinely used due to the risks, costs and technical challengers. We are developing a non-invasive brain oximeter to address these limitations. The monitor uses the principles of pulse oximetry to record a brain photoplethysmographic waveform and oxygen saturations. We undertook a study in volunteers to assess the new monitor. PATIENTS AND METHODS: We compared the temporal changes in the brain and skin oxygen saturations in six volunteers undergoing progressive hypoxia to reach arterial saturations of 70%. This approach provides a method to discriminate potential contamination of the brain signal by skin oxygen levels, as the responses in brain and skin oxygen saturations are distinct due to the auto-regulation of cerebral blood flow to compensate for hypoxia. Conventional pulse oximetry was used to assess skin oxygen levels. Blood was also collected from the internal jugular vein and correlated with the brain oximeter oxygen levels. RESULTS: At baseline, a photoplethysmographic waveform consistent with that expected from the brain was obtained in five subjects. The signal was adequate to assess oxygen saturations in three subjects. During hypoxia, the brain's oximeter oxygen saturation fell to 74%, while skin saturation fell to 50% (P<0.0001). The brain photoplethysmographic waveform developed a high-frequency oscillation of ~7 Hz, which was not present in the skin during hypoxia. A weak correlation between the brain oximeter and proximal internal jugular vein oxygen levels was demonstrated, R(2)=0.24, P=0.01. CONCLUSION: Brain oximeter oxygen saturations were relatively well preserved compared to the skin during hypoxia. These findings are consistent with the expected physiological responses and suggest skin oxygen levels did not markedly contaminate the brain oximeter signal. |
format | Online Article Text |
id | pubmed-7335769 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-73357692020-07-14 Assessment of a Non Invasive Brain Oximeter in Volunteers Undergoing Acute Hypoxia Dixon, Barry MacLeod, David B Med Devices (Auckl) Original Research INTRODUCTION: Research in traumatic brain injury suggests better patient outcomes when invasive oxygen monitoring is used to detect and correct episodes of brain hypoxia. Invasive brain oxygen monitoring is, however, not routinely used due to the risks, costs and technical challengers. We are developing a non-invasive brain oximeter to address these limitations. The monitor uses the principles of pulse oximetry to record a brain photoplethysmographic waveform and oxygen saturations. We undertook a study in volunteers to assess the new monitor. PATIENTS AND METHODS: We compared the temporal changes in the brain and skin oxygen saturations in six volunteers undergoing progressive hypoxia to reach arterial saturations of 70%. This approach provides a method to discriminate potential contamination of the brain signal by skin oxygen levels, as the responses in brain and skin oxygen saturations are distinct due to the auto-regulation of cerebral blood flow to compensate for hypoxia. Conventional pulse oximetry was used to assess skin oxygen levels. Blood was also collected from the internal jugular vein and correlated with the brain oximeter oxygen levels. RESULTS: At baseline, a photoplethysmographic waveform consistent with that expected from the brain was obtained in five subjects. The signal was adequate to assess oxygen saturations in three subjects. During hypoxia, the brain's oximeter oxygen saturation fell to 74%, while skin saturation fell to 50% (P<0.0001). The brain photoplethysmographic waveform developed a high-frequency oscillation of ~7 Hz, which was not present in the skin during hypoxia. A weak correlation between the brain oximeter and proximal internal jugular vein oxygen levels was demonstrated, R(2)=0.24, P=0.01. CONCLUSION: Brain oximeter oxygen saturations were relatively well preserved compared to the skin during hypoxia. These findings are consistent with the expected physiological responses and suggest skin oxygen levels did not markedly contaminate the brain oximeter signal. Dove 2020-06-30 /pmc/articles/PMC7335769/ /pubmed/32669881 http://dx.doi.org/10.2147/MDER.S250102 Text en © 2020 Dixon and MacLeod. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Dixon, Barry MacLeod, David B Assessment of a Non Invasive Brain Oximeter in Volunteers Undergoing Acute Hypoxia |
title | Assessment of a Non Invasive Brain Oximeter in Volunteers Undergoing Acute Hypoxia |
title_full | Assessment of a Non Invasive Brain Oximeter in Volunteers Undergoing Acute Hypoxia |
title_fullStr | Assessment of a Non Invasive Brain Oximeter in Volunteers Undergoing Acute Hypoxia |
title_full_unstemmed | Assessment of a Non Invasive Brain Oximeter in Volunteers Undergoing Acute Hypoxia |
title_short | Assessment of a Non Invasive Brain Oximeter in Volunteers Undergoing Acute Hypoxia |
title_sort | assessment of a non invasive brain oximeter in volunteers undergoing acute hypoxia |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7335769/ https://www.ncbi.nlm.nih.gov/pubmed/32669881 http://dx.doi.org/10.2147/MDER.S250102 |
work_keys_str_mv | AT dixonbarry assessmentofanoninvasivebrainoximeterinvolunteersundergoingacutehypoxia AT macleoddavidb assessmentofanoninvasivebrainoximeterinvolunteersundergoingacutehypoxia |