Cargando…
Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
We investigated the feasibility of a robust optimization with 6 MV X-ray (6X) and 10 MV X-ray (10X) flattening filter-free (FFF) beams in a volumetric modulated arc therapy (VMAT) plan for lung stereotactic body radiation therapy (SBRT) using a breath-holding technique. Ten lung cancer patients were...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7336549/ https://www.ncbi.nlm.nih.gov/pubmed/32367109 http://dx.doi.org/10.1093/jrr/rraa026 |
_version_ | 1783554338868690944 |
---|---|
author | Miura, Hideharu Ozawa, Shuichi Doi, Yoshiko Nakao, Minoru Kubo, Katsumaro Kenjo, Masahiko Nagata, Yasushi |
author_facet | Miura, Hideharu Ozawa, Shuichi Doi, Yoshiko Nakao, Minoru Kubo, Katsumaro Kenjo, Masahiko Nagata, Yasushi |
author_sort | Miura, Hideharu |
collection | PubMed |
description | We investigated the feasibility of a robust optimization with 6 MV X-ray (6X) and 10 MV X-ray (10X) flattening filter-free (FFF) beams in a volumetric modulated arc therapy (VMAT) plan for lung stereotactic body radiation therapy (SBRT) using a breath-holding technique. Ten lung cancer patients were selected. Four VMAT plans were generated for each patient; namely, an optimized plan based on the planning target volume (PTV) margin and a second plan based on a robust optimization of the internal target volume (ITV) with setup uncertainties, each for the 6X- and 10X-FFF beams. Both optimized plans were normalized by the percentage of the prescription dose covering 95% of the target volume (D(95%)) to the PTV (1050 cGy × 4 fractions). All optimized plans were evaluated using perturbed doses by specifying user-defined shifted values from the isocentre. The average perturbed D(99%) doses to the ITV, compared to the nominal plan, decreased by 369.1 (6X-FFF) and 301.0 cGy (10X-FFF) for the PTV-based optimized plan, and 346.0 (6X-FFF) and 271.6 cGy (10X-FFF) for the robust optimized plan, respectively. The standard deviation of the D(99%) dose to the ITV were 163.6 (6X-FFF) and 158.9 cGy (10X-FFF) for the PTV-based plan, and 138.9 (6X-FFF) and 128.5 cGy (10X-FFF) for the robust optimized plan, respectively. Robust optimized plans with 10X-FFF beams is a feasible method to achieve dose certainty for the ITV for lung SBRT using a breath-holding technique. |
format | Online Article Text |
id | pubmed-7336549 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-73365492020-07-13 Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique Miura, Hideharu Ozawa, Shuichi Doi, Yoshiko Nakao, Minoru Kubo, Katsumaro Kenjo, Masahiko Nagata, Yasushi J Radiat Res Regular Paper We investigated the feasibility of a robust optimization with 6 MV X-ray (6X) and 10 MV X-ray (10X) flattening filter-free (FFF) beams in a volumetric modulated arc therapy (VMAT) plan for lung stereotactic body radiation therapy (SBRT) using a breath-holding technique. Ten lung cancer patients were selected. Four VMAT plans were generated for each patient; namely, an optimized plan based on the planning target volume (PTV) margin and a second plan based on a robust optimization of the internal target volume (ITV) with setup uncertainties, each for the 6X- and 10X-FFF beams. Both optimized plans were normalized by the percentage of the prescription dose covering 95% of the target volume (D(95%)) to the PTV (1050 cGy × 4 fractions). All optimized plans were evaluated using perturbed doses by specifying user-defined shifted values from the isocentre. The average perturbed D(99%) doses to the ITV, compared to the nominal plan, decreased by 369.1 (6X-FFF) and 301.0 cGy (10X-FFF) for the PTV-based optimized plan, and 346.0 (6X-FFF) and 271.6 cGy (10X-FFF) for the robust optimized plan, respectively. The standard deviation of the D(99%) dose to the ITV were 163.6 (6X-FFF) and 158.9 cGy (10X-FFF) for the PTV-based plan, and 138.9 (6X-FFF) and 128.5 cGy (10X-FFF) for the robust optimized plan, respectively. Robust optimized plans with 10X-FFF beams is a feasible method to achieve dose certainty for the ITV for lung SBRT using a breath-holding technique. Oxford University Press 2020-05-05 /pmc/articles/PMC7336549/ /pubmed/32367109 http://dx.doi.org/10.1093/jrr/rraa026 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Regular Paper Miura, Hideharu Ozawa, Shuichi Doi, Yoshiko Nakao, Minoru Kubo, Katsumaro Kenjo, Masahiko Nagata, Yasushi Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique |
title | Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique |
title_full | Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique |
title_fullStr | Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique |
title_full_unstemmed | Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique |
title_short | Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique |
title_sort | effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 mv flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique |
topic | Regular Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7336549/ https://www.ncbi.nlm.nih.gov/pubmed/32367109 http://dx.doi.org/10.1093/jrr/rraa026 |
work_keys_str_mv | AT miurahideharu effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique AT ozawashuichi effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique AT doiyoshiko effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique AT nakaominoru effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique AT kubokatsumaro effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique AT kenjomasahiko effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique AT nagatayasushi effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique |