Cargando…

Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique

We investigated the feasibility of a robust optimization with 6 MV X-ray (6X) and 10 MV X-ray (10X) flattening filter-free (FFF) beams in a volumetric modulated arc therapy (VMAT) plan for lung stereotactic body radiation therapy (SBRT) using a breath-holding technique. Ten lung cancer patients were...

Descripción completa

Detalles Bibliográficos
Autores principales: Miura, Hideharu, Ozawa, Shuichi, Doi, Yoshiko, Nakao, Minoru, Kubo, Katsumaro, Kenjo, Masahiko, Nagata, Yasushi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7336549/
https://www.ncbi.nlm.nih.gov/pubmed/32367109
http://dx.doi.org/10.1093/jrr/rraa026
_version_ 1783554338868690944
author Miura, Hideharu
Ozawa, Shuichi
Doi, Yoshiko
Nakao, Minoru
Kubo, Katsumaro
Kenjo, Masahiko
Nagata, Yasushi
author_facet Miura, Hideharu
Ozawa, Shuichi
Doi, Yoshiko
Nakao, Minoru
Kubo, Katsumaro
Kenjo, Masahiko
Nagata, Yasushi
author_sort Miura, Hideharu
collection PubMed
description We investigated the feasibility of a robust optimization with 6 MV X-ray (6X) and 10 MV X-ray (10X) flattening filter-free (FFF) beams in a volumetric modulated arc therapy (VMAT) plan for lung stereotactic body radiation therapy (SBRT) using a breath-holding technique. Ten lung cancer patients were selected. Four VMAT plans were generated for each patient; namely, an optimized plan based on the planning target volume (PTV) margin and a second plan based on a robust optimization of the internal target volume (ITV) with setup uncertainties, each for the 6X- and 10X-FFF beams. Both optimized plans were normalized by the percentage of the prescription dose covering 95% of the target volume (D(95%)) to the PTV (1050 cGy × 4 fractions). All optimized plans were evaluated using perturbed doses by specifying user-defined shifted values from the isocentre. The average perturbed D(99%) doses to the ITV, compared to the nominal plan, decreased by 369.1 (6X-FFF) and 301.0 cGy (10X-FFF) for the PTV-based optimized plan, and 346.0 (6X-FFF) and 271.6 cGy (10X-FFF) for the robust optimized plan, respectively. The standard deviation of the D(99%) dose to the ITV were 163.6 (6X-FFF) and 158.9 cGy (10X-FFF) for the PTV-based plan, and 138.9 (6X-FFF) and 128.5 cGy (10X-FFF) for the robust optimized plan, respectively. Robust optimized plans with 10X-FFF beams is a feasible method to achieve dose certainty for the ITV for lung SBRT using a breath-holding technique.
format Online
Article
Text
id pubmed-7336549
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-73365492020-07-13 Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique Miura, Hideharu Ozawa, Shuichi Doi, Yoshiko Nakao, Minoru Kubo, Katsumaro Kenjo, Masahiko Nagata, Yasushi J Radiat Res Regular Paper We investigated the feasibility of a robust optimization with 6 MV X-ray (6X) and 10 MV X-ray (10X) flattening filter-free (FFF) beams in a volumetric modulated arc therapy (VMAT) plan for lung stereotactic body radiation therapy (SBRT) using a breath-holding technique. Ten lung cancer patients were selected. Four VMAT plans were generated for each patient; namely, an optimized plan based on the planning target volume (PTV) margin and a second plan based on a robust optimization of the internal target volume (ITV) with setup uncertainties, each for the 6X- and 10X-FFF beams. Both optimized plans were normalized by the percentage of the prescription dose covering 95% of the target volume (D(95%)) to the PTV (1050 cGy × 4 fractions). All optimized plans were evaluated using perturbed doses by specifying user-defined shifted values from the isocentre. The average perturbed D(99%) doses to the ITV, compared to the nominal plan, decreased by 369.1 (6X-FFF) and 301.0 cGy (10X-FFF) for the PTV-based optimized plan, and 346.0 (6X-FFF) and 271.6 cGy (10X-FFF) for the robust optimized plan, respectively. The standard deviation of the D(99%) dose to the ITV were 163.6 (6X-FFF) and 158.9 cGy (10X-FFF) for the PTV-based plan, and 138.9 (6X-FFF) and 128.5 cGy (10X-FFF) for the robust optimized plan, respectively. Robust optimized plans with 10X-FFF beams is a feasible method to achieve dose certainty for the ITV for lung SBRT using a breath-holding technique. Oxford University Press 2020-05-05 /pmc/articles/PMC7336549/ /pubmed/32367109 http://dx.doi.org/10.1093/jrr/rraa026 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Regular Paper
Miura, Hideharu
Ozawa, Shuichi
Doi, Yoshiko
Nakao, Minoru
Kubo, Katsumaro
Kenjo, Masahiko
Nagata, Yasushi
Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
title Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
title_full Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
title_fullStr Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
title_full_unstemmed Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
title_short Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
title_sort effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 mv flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
topic Regular Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7336549/
https://www.ncbi.nlm.nih.gov/pubmed/32367109
http://dx.doi.org/10.1093/jrr/rraa026
work_keys_str_mv AT miurahideharu effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique
AT ozawashuichi effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique
AT doiyoshiko effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique
AT nakaominoru effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique
AT kubokatsumaro effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique
AT kenjomasahiko effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique
AT nagatayasushi effectivenessofrobustoptimizationinvolumetricmodulatedarctherapyusing6and10mvflatteningfilterfreebeamtherapyplanningforlungstereotacticbodyradiationtherapywithabreathholdtechnique