Cargando…
Non-destructive lock-picking of a historical treasure chest by means of X-ray computed tomography
An innovative approach to a non-destructive lock mechanism examination by means of X-ray computed tomography (CT) was involved in a careful opening of a locked 19(th) century chest missing the key, as an interdisciplinary cooperation with the restorers. In regard of the exploration and conservation...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7337312/ https://www.ncbi.nlm.nih.gov/pubmed/32628704 http://dx.doi.org/10.1371/journal.pone.0235316 |
_version_ | 1783554484076544000 |
---|---|
author | Zikmundová, Eva Zikmund, Tomáš Sládek, Vladimír Kaiser, Jozef |
author_facet | Zikmundová, Eva Zikmund, Tomáš Sládek, Vladimír Kaiser, Jozef |
author_sort | Zikmundová, Eva |
collection | PubMed |
description | An innovative approach to a non-destructive lock mechanism examination by means of X-ray computed tomography (CT) was involved in a careful opening of a locked 19(th) century chest missing the key, as an interdisciplinary cooperation with the restorers. In regard of the exploration and conservation of such locked objects, their opening is important to the restorers. However, the opening may be complicated, if not impossible, without damaging the object when the key is missing. Moreover, the historical locks might be equipped with protective mechanisms. Despite the exceeding dimensions and the weight of the steel chest, a CT analysis was performed, which enabled a detailed exploration of the lock based on a system of levers and bolts handled by a single key, located in a case on the inside of the chest lid, including the dimensions essential for manufacturing of a new key copy. Moreover, two secret protective mechanisms were revealed, as well as all the damages of the object. |
format | Online Article Text |
id | pubmed-7337312 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-73373122020-07-16 Non-destructive lock-picking of a historical treasure chest by means of X-ray computed tomography Zikmundová, Eva Zikmund, Tomáš Sládek, Vladimír Kaiser, Jozef PLoS One Research Article An innovative approach to a non-destructive lock mechanism examination by means of X-ray computed tomography (CT) was involved in a careful opening of a locked 19(th) century chest missing the key, as an interdisciplinary cooperation with the restorers. In regard of the exploration and conservation of such locked objects, their opening is important to the restorers. However, the opening may be complicated, if not impossible, without damaging the object when the key is missing. Moreover, the historical locks might be equipped with protective mechanisms. Despite the exceeding dimensions and the weight of the steel chest, a CT analysis was performed, which enabled a detailed exploration of the lock based on a system of levers and bolts handled by a single key, located in a case on the inside of the chest lid, including the dimensions essential for manufacturing of a new key copy. Moreover, two secret protective mechanisms were revealed, as well as all the damages of the object. Public Library of Science 2020-07-06 /pmc/articles/PMC7337312/ /pubmed/32628704 http://dx.doi.org/10.1371/journal.pone.0235316 Text en © 2020 Zikmundová et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Zikmundová, Eva Zikmund, Tomáš Sládek, Vladimír Kaiser, Jozef Non-destructive lock-picking of a historical treasure chest by means of X-ray computed tomography |
title | Non-destructive lock-picking of a historical treasure chest by means of X-ray computed tomography |
title_full | Non-destructive lock-picking of a historical treasure chest by means of X-ray computed tomography |
title_fullStr | Non-destructive lock-picking of a historical treasure chest by means of X-ray computed tomography |
title_full_unstemmed | Non-destructive lock-picking of a historical treasure chest by means of X-ray computed tomography |
title_short | Non-destructive lock-picking of a historical treasure chest by means of X-ray computed tomography |
title_sort | non-destructive lock-picking of a historical treasure chest by means of x-ray computed tomography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7337312/ https://www.ncbi.nlm.nih.gov/pubmed/32628704 http://dx.doi.org/10.1371/journal.pone.0235316 |
work_keys_str_mv | AT zikmundovaeva nondestructivelockpickingofahistoricaltreasurechestbymeansofxraycomputedtomography AT zikmundtomas nondestructivelockpickingofahistoricaltreasurechestbymeansofxraycomputedtomography AT sladekvladimir nondestructivelockpickingofahistoricaltreasurechestbymeansofxraycomputedtomography AT kaiserjozef nondestructivelockpickingofahistoricaltreasurechestbymeansofxraycomputedtomography |