Cargando…

Comparison of a Continuous Noninvasive Temperature to Monitor Core Temperature Measures During Targeted Temperature Management

BACKGROUND: Temperature modulating devices (TMD) currently utilize core temperature measurements during targeted temperature management (TTM) that are currently limited to esophageal (Et), bladder (Bt), or rectal (Rt) temperatures. We assessed the ability of a continuous noninvasive temperature moni...

Descripción completa

Detalles Bibliográficos
Autores principales: Wagner, Melissa, Lim-Hing, Krista, Bautista, Mary Ann, Blaber, Brigid, Ryder, Taghi, Haymore, Joseph, Badjatia, Neeraj
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7338135/
https://www.ncbi.nlm.nih.gov/pubmed/32632906
http://dx.doi.org/10.1007/s12028-020-01036-9
_version_ 1783554615577411584
author Wagner, Melissa
Lim-Hing, Krista
Bautista, Mary Ann
Blaber, Brigid
Ryder, Taghi
Haymore, Joseph
Badjatia, Neeraj
author_facet Wagner, Melissa
Lim-Hing, Krista
Bautista, Mary Ann
Blaber, Brigid
Ryder, Taghi
Haymore, Joseph
Badjatia, Neeraj
author_sort Wagner, Melissa
collection PubMed
description BACKGROUND: Temperature modulating devices (TMD) currently utilize core temperature measurements during targeted temperature management (TTM) that are currently limited to esophageal (Et), bladder (Bt), or rectal (Rt) temperatures. We assessed the ability of a continuous noninvasive temperature monitor to accurately approximate core temperature during TTM. METHODS: All patients undergoing TTM using a gel pad surface TMD and an existing core temperature monitoring device were eligible for this study. Core and continuous noninvasive temperature monitoring values were simultaneously recorded for up to 72 h of TTM. The two sets of temperature data were downloaded from a clinical data acquisition storage system at 1-min intervals. The Bland–Altman method assessed agreement between the core and continuous noninvasive temperature monitor values, by measuring the mean difference (± 2 SD) between these values. RESULTS: There were 20 subjects that underwent study between January 2018 and March 2018 (55% women, age: 57 ± 14 years old, BMI: 28.9 + 9.8 kg/m(2), 100% mechanically ventilated). The comparison patient temperature source was predominantly esophageal (n = 10) followed by bladder (n = 5) or rectal (n = 5). There were a total of 999 h of paired patient temperature data from esophageal (50%), bladder (25%), and rectal (25%) temperatures. Bland–Altman analysis demonstrated good agreement with the superficial temperature monitor and core temperature measures in all patients overall, with a difference mean of 0.06 ± 0.39 C (P = 0.99) and no proportional bias noted (β =0.002, P = 0.917). CONCLUSIONS: Continuous noninvasive temperature monitoring is a suitable alternative method for assessing core temperature during TTM. Future studies should focus on developing connectivity with a continuous noninvasive temperature monitor to approximate core temperature during TTM.
format Online
Article
Text
id pubmed-7338135
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-73381352020-07-07 Comparison of a Continuous Noninvasive Temperature to Monitor Core Temperature Measures During Targeted Temperature Management Wagner, Melissa Lim-Hing, Krista Bautista, Mary Ann Blaber, Brigid Ryder, Taghi Haymore, Joseph Badjatia, Neeraj Neurocrit Care Original Work BACKGROUND: Temperature modulating devices (TMD) currently utilize core temperature measurements during targeted temperature management (TTM) that are currently limited to esophageal (Et), bladder (Bt), or rectal (Rt) temperatures. We assessed the ability of a continuous noninvasive temperature monitor to accurately approximate core temperature during TTM. METHODS: All patients undergoing TTM using a gel pad surface TMD and an existing core temperature monitoring device were eligible for this study. Core and continuous noninvasive temperature monitoring values were simultaneously recorded for up to 72 h of TTM. The two sets of temperature data were downloaded from a clinical data acquisition storage system at 1-min intervals. The Bland–Altman method assessed agreement between the core and continuous noninvasive temperature monitor values, by measuring the mean difference (± 2 SD) between these values. RESULTS: There were 20 subjects that underwent study between January 2018 and March 2018 (55% women, age: 57 ± 14 years old, BMI: 28.9 + 9.8 kg/m(2), 100% mechanically ventilated). The comparison patient temperature source was predominantly esophageal (n = 10) followed by bladder (n = 5) or rectal (n = 5). There were a total of 999 h of paired patient temperature data from esophageal (50%), bladder (25%), and rectal (25%) temperatures. Bland–Altman analysis demonstrated good agreement with the superficial temperature monitor and core temperature measures in all patients overall, with a difference mean of 0.06 ± 0.39 C (P = 0.99) and no proportional bias noted (β =0.002, P = 0.917). CONCLUSIONS: Continuous noninvasive temperature monitoring is a suitable alternative method for assessing core temperature during TTM. Future studies should focus on developing connectivity with a continuous noninvasive temperature monitor to approximate core temperature during TTM. Springer US 2020-07-06 2021 /pmc/articles/PMC7338135/ /pubmed/32632906 http://dx.doi.org/10.1007/s12028-020-01036-9 Text en © Springer Science+Business Media, LLC, part of Springer Nature and Neurocritical Care Society 2020 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Original Work
Wagner, Melissa
Lim-Hing, Krista
Bautista, Mary Ann
Blaber, Brigid
Ryder, Taghi
Haymore, Joseph
Badjatia, Neeraj
Comparison of a Continuous Noninvasive Temperature to Monitor Core Temperature Measures During Targeted Temperature Management
title Comparison of a Continuous Noninvasive Temperature to Monitor Core Temperature Measures During Targeted Temperature Management
title_full Comparison of a Continuous Noninvasive Temperature to Monitor Core Temperature Measures During Targeted Temperature Management
title_fullStr Comparison of a Continuous Noninvasive Temperature to Monitor Core Temperature Measures During Targeted Temperature Management
title_full_unstemmed Comparison of a Continuous Noninvasive Temperature to Monitor Core Temperature Measures During Targeted Temperature Management
title_short Comparison of a Continuous Noninvasive Temperature to Monitor Core Temperature Measures During Targeted Temperature Management
title_sort comparison of a continuous noninvasive temperature to monitor core temperature measures during targeted temperature management
topic Original Work
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7338135/
https://www.ncbi.nlm.nih.gov/pubmed/32632906
http://dx.doi.org/10.1007/s12028-020-01036-9
work_keys_str_mv AT wagnermelissa comparisonofacontinuousnoninvasivetemperaturetomonitorcoretemperaturemeasuresduringtargetedtemperaturemanagement
AT limhingkrista comparisonofacontinuousnoninvasivetemperaturetomonitorcoretemperaturemeasuresduringtargetedtemperaturemanagement
AT bautistamaryann comparisonofacontinuousnoninvasivetemperaturetomonitorcoretemperaturemeasuresduringtargetedtemperaturemanagement
AT blaberbrigid comparisonofacontinuousnoninvasivetemperaturetomonitorcoretemperaturemeasuresduringtargetedtemperaturemanagement
AT rydertaghi comparisonofacontinuousnoninvasivetemperaturetomonitorcoretemperaturemeasuresduringtargetedtemperaturemanagement
AT haymorejoseph comparisonofacontinuousnoninvasivetemperaturetomonitorcoretemperaturemeasuresduringtargetedtemperaturemanagement
AT badjatianeeraj comparisonofacontinuousnoninvasivetemperaturetomonitorcoretemperaturemeasuresduringtargetedtemperaturemanagement