Cargando…

Performance of PEth Compared With Other Alcohol Biomarkers in Subjects Presenting For Occupational and Pre-Employment Medical Examination

AIMS: To compare the performance of short- and long-term alcohol biomarkers for the evaluation of alcohol drinking in employment-related health controls. METHODS: The 519 blood samples originated from 509 patients (80% men) presenting at occupational health units and medical centers at employment ag...

Descripción completa

Detalles Bibliográficos
Autores principales: Neumann, Jasna, Beck, Olof, Helander, Anders, Böttcher, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7338721/
https://www.ncbi.nlm.nih.gov/pubmed/32363383
http://dx.doi.org/10.1093/alcalc/agaa027
_version_ 1783554743998611456
author Neumann, Jasna
Beck, Olof
Helander, Anders
Böttcher, Michael
author_facet Neumann, Jasna
Beck, Olof
Helander, Anders
Böttcher, Michael
author_sort Neumann, Jasna
collection PubMed
description AIMS: To compare the performance of short- and long-term alcohol biomarkers for the evaluation of alcohol drinking in employment-related health controls. METHODS: The 519 blood samples originated from 509 patients (80% men) presenting at occupational health units and medical centers at employment agencies for the evaluation of risky drinking. The laboratory investigation comprised the measurement of phosphatidylethanol (PEth 16:0/18:1), carbohydrate-deficient transferrin (CDT; % disialotransferrin), gamma-glutamyl transferase (GGT), mean corpuscular volume (MCV), ethanol and ethyl glucuronide (EtG). RESULTS: Many samples tested positive for acute (57%) and chronic (69%) alcohol biomarkers. PEth was the single most positive biomarker (64%; cut-off 0.05 μmol/l or 35 μg/l) and the only positive chronic biomarker in 100 cases. The highest PEth concentrations were seen in samples positive for all chronic biomarkers, followed by those also being CDT positive (cut-off 2.0%). All 126 CDT-positive samples were positive for PEth using the lower reporting limit (≥0.05 μmol/l) and for 114 cases (90%) also using the higher limit (≥0.30 μmol/l or 210 μg/l). In the CDT-positive cases, the PEth median concentration was 1.71 μmol/l, compared with 0.45 μmol/l for the CDT-negative cases (P < 0.0001). PEth and CDT values were correlated significantly (r = 0.63, P < 0.0001). Among the EtG-positive cases (≥1.0 ng/ml), 95% were also PEth positive, and all ethanol-positive cases (≥0.10 g/l) were also PEth positive. CONCLUSIONS: For optimal detection of drinking habits, using a combination of short- and long-term alcohol biomarkers provided best information. PEth was the single most positive alcohol biomarker, whereas GGT and MCV offered little additional value over PEth and CDT.
format Online
Article
Text
id pubmed-7338721
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-73387212020-07-13 Performance of PEth Compared With Other Alcohol Biomarkers in Subjects Presenting For Occupational and Pre-Employment Medical Examination Neumann, Jasna Beck, Olof Helander, Anders Böttcher, Michael Alcohol Alcohol Article AIMS: To compare the performance of short- and long-term alcohol biomarkers for the evaluation of alcohol drinking in employment-related health controls. METHODS: The 519 blood samples originated from 509 patients (80% men) presenting at occupational health units and medical centers at employment agencies for the evaluation of risky drinking. The laboratory investigation comprised the measurement of phosphatidylethanol (PEth 16:0/18:1), carbohydrate-deficient transferrin (CDT; % disialotransferrin), gamma-glutamyl transferase (GGT), mean corpuscular volume (MCV), ethanol and ethyl glucuronide (EtG). RESULTS: Many samples tested positive for acute (57%) and chronic (69%) alcohol biomarkers. PEth was the single most positive biomarker (64%; cut-off 0.05 μmol/l or 35 μg/l) and the only positive chronic biomarker in 100 cases. The highest PEth concentrations were seen in samples positive for all chronic biomarkers, followed by those also being CDT positive (cut-off 2.0%). All 126 CDT-positive samples were positive for PEth using the lower reporting limit (≥0.05 μmol/l) and for 114 cases (90%) also using the higher limit (≥0.30 μmol/l or 210 μg/l). In the CDT-positive cases, the PEth median concentration was 1.71 μmol/l, compared with 0.45 μmol/l for the CDT-negative cases (P < 0.0001). PEth and CDT values were correlated significantly (r = 0.63, P < 0.0001). Among the EtG-positive cases (≥1.0 ng/ml), 95% were also PEth positive, and all ethanol-positive cases (≥0.10 g/l) were also PEth positive. CONCLUSIONS: For optimal detection of drinking habits, using a combination of short- and long-term alcohol biomarkers provided best information. PEth was the single most positive alcohol biomarker, whereas GGT and MCV offered little additional value over PEth and CDT. Oxford University Press 2020-06 2020-05-04 /pmc/articles/PMC7338721/ /pubmed/32363383 http://dx.doi.org/10.1093/alcalc/agaa027 Text en © The Author(s) 2020. Published by Oxford University Press. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Neumann, Jasna
Beck, Olof
Helander, Anders
Böttcher, Michael
Performance of PEth Compared With Other Alcohol Biomarkers in Subjects Presenting For Occupational and Pre-Employment Medical Examination
title Performance of PEth Compared With Other Alcohol Biomarkers in Subjects Presenting For Occupational and Pre-Employment Medical Examination
title_full Performance of PEth Compared With Other Alcohol Biomarkers in Subjects Presenting For Occupational and Pre-Employment Medical Examination
title_fullStr Performance of PEth Compared With Other Alcohol Biomarkers in Subjects Presenting For Occupational and Pre-Employment Medical Examination
title_full_unstemmed Performance of PEth Compared With Other Alcohol Biomarkers in Subjects Presenting For Occupational and Pre-Employment Medical Examination
title_short Performance of PEth Compared With Other Alcohol Biomarkers in Subjects Presenting For Occupational and Pre-Employment Medical Examination
title_sort performance of peth compared with other alcohol biomarkers in subjects presenting for occupational and pre-employment medical examination
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7338721/
https://www.ncbi.nlm.nih.gov/pubmed/32363383
http://dx.doi.org/10.1093/alcalc/agaa027
work_keys_str_mv AT neumannjasna performanceofpethcomparedwithotheralcoholbiomarkersinsubjectspresentingforoccupationalandpreemploymentmedicalexamination
AT beckolof performanceofpethcomparedwithotheralcoholbiomarkersinsubjectspresentingforoccupationalandpreemploymentmedicalexamination
AT helanderanders performanceofpethcomparedwithotheralcoholbiomarkersinsubjectspresentingforoccupationalandpreemploymentmedicalexamination
AT bottchermichael performanceofpethcomparedwithotheralcoholbiomarkersinsubjectspresentingforoccupationalandpreemploymentmedicalexamination