Cargando…

Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe

Recently, we demonstrated an integrated photoacoustic (PA) and ultrasound (PAUS) system using a kHz-rate wavelength-tunable laser and a swept-beam delivery approach. It irradiates a medium using a narrow laser beam swept at high repetition rate (∼1 kHz) over the desired imaging area, in contrast to...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, MinWoo, Jeng, Geng-Shi, O’Donnell, Matthew, Pelivanov, Ivan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7339128/
https://www.ncbi.nlm.nih.gov/pubmed/32670789
http://dx.doi.org/10.1016/j.pacs.2020.100192
_version_ 1783554826449190912
author Kim, MinWoo
Jeng, Geng-Shi
O’Donnell, Matthew
Pelivanov, Ivan
author_facet Kim, MinWoo
Jeng, Geng-Shi
O’Donnell, Matthew
Pelivanov, Ivan
author_sort Kim, MinWoo
collection PubMed
description Recently, we demonstrated an integrated photoacoustic (PA) and ultrasound (PAUS) system using a kHz-rate wavelength-tunable laser and a swept-beam delivery approach. It irradiates a medium using a narrow laser beam swept at high repetition rate (∼1 kHz) over the desired imaging area, in contrast to the conventional PA approach using broad-beam illumination at a low repetition rate (10−50 Hz). Here, we present a method to correct the wavelength-dependent fluence distribution and demonstrate its performance in phantom studies using a conventional limited view/bandwidth hand-held US probe. We adopted analytic fluence models, extending diffusion theory for the case of a pencil beam obliquely incident on an optically homogenous turbid medium, and developed a robust method to estimate fluence attenuation in the medium using PA measurements acquired from multiple fiber-irradiation positions swept at a kHz rate. We conducted comprehensive simulation tests and phantom studies using well-known contrast-agents to validate the reliability of the fluence model and its spectral corrections.
format Online
Article
Text
id pubmed-7339128
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-73391282020-07-14 Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe Kim, MinWoo Jeng, Geng-Shi O’Donnell, Matthew Pelivanov, Ivan Photoacoustics Research Article Recently, we demonstrated an integrated photoacoustic (PA) and ultrasound (PAUS) system using a kHz-rate wavelength-tunable laser and a swept-beam delivery approach. It irradiates a medium using a narrow laser beam swept at high repetition rate (∼1 kHz) over the desired imaging area, in contrast to the conventional PA approach using broad-beam illumination at a low repetition rate (10−50 Hz). Here, we present a method to correct the wavelength-dependent fluence distribution and demonstrate its performance in phantom studies using a conventional limited view/bandwidth hand-held US probe. We adopted analytic fluence models, extending diffusion theory for the case of a pencil beam obliquely incident on an optically homogenous turbid medium, and developed a robust method to estimate fluence attenuation in the medium using PA measurements acquired from multiple fiber-irradiation positions swept at a kHz rate. We conducted comprehensive simulation tests and phantom studies using well-known contrast-agents to validate the reliability of the fluence model and its spectral corrections. Elsevier 2020-05-21 /pmc/articles/PMC7339128/ /pubmed/32670789 http://dx.doi.org/10.1016/j.pacs.2020.100192 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Kim, MinWoo
Jeng, Geng-Shi
O’Donnell, Matthew
Pelivanov, Ivan
Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe
title Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe
title_full Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe
title_fullStr Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe
title_full_unstemmed Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe
title_short Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe
title_sort correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7339128/
https://www.ncbi.nlm.nih.gov/pubmed/32670789
http://dx.doi.org/10.1016/j.pacs.2020.100192
work_keys_str_mv AT kimminwoo correctionofwavelengthdependentlaserfluenceinsweptbeamspectroscopicphotoacousticimagingwithahandheldprobe
AT jenggengshi correctionofwavelengthdependentlaserfluenceinsweptbeamspectroscopicphotoacousticimagingwithahandheldprobe
AT odonnellmatthew correctionofwavelengthdependentlaserfluenceinsweptbeamspectroscopicphotoacousticimagingwithahandheldprobe
AT pelivanovivan correctionofwavelengthdependentlaserfluenceinsweptbeamspectroscopicphotoacousticimagingwithahandheldprobe