Cargando…
Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe
Recently, we demonstrated an integrated photoacoustic (PA) and ultrasound (PAUS) system using a kHz-rate wavelength-tunable laser and a swept-beam delivery approach. It irradiates a medium using a narrow laser beam swept at high repetition rate (∼1 kHz) over the desired imaging area, in contrast to...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7339128/ https://www.ncbi.nlm.nih.gov/pubmed/32670789 http://dx.doi.org/10.1016/j.pacs.2020.100192 |
_version_ | 1783554826449190912 |
---|---|
author | Kim, MinWoo Jeng, Geng-Shi O’Donnell, Matthew Pelivanov, Ivan |
author_facet | Kim, MinWoo Jeng, Geng-Shi O’Donnell, Matthew Pelivanov, Ivan |
author_sort | Kim, MinWoo |
collection | PubMed |
description | Recently, we demonstrated an integrated photoacoustic (PA) and ultrasound (PAUS) system using a kHz-rate wavelength-tunable laser and a swept-beam delivery approach. It irradiates a medium using a narrow laser beam swept at high repetition rate (∼1 kHz) over the desired imaging area, in contrast to the conventional PA approach using broad-beam illumination at a low repetition rate (10−50 Hz). Here, we present a method to correct the wavelength-dependent fluence distribution and demonstrate its performance in phantom studies using a conventional limited view/bandwidth hand-held US probe. We adopted analytic fluence models, extending diffusion theory for the case of a pencil beam obliquely incident on an optically homogenous turbid medium, and developed a robust method to estimate fluence attenuation in the medium using PA measurements acquired from multiple fiber-irradiation positions swept at a kHz rate. We conducted comprehensive simulation tests and phantom studies using well-known contrast-agents to validate the reliability of the fluence model and its spectral corrections. |
format | Online Article Text |
id | pubmed-7339128 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-73391282020-07-14 Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe Kim, MinWoo Jeng, Geng-Shi O’Donnell, Matthew Pelivanov, Ivan Photoacoustics Research Article Recently, we demonstrated an integrated photoacoustic (PA) and ultrasound (PAUS) system using a kHz-rate wavelength-tunable laser and a swept-beam delivery approach. It irradiates a medium using a narrow laser beam swept at high repetition rate (∼1 kHz) over the desired imaging area, in contrast to the conventional PA approach using broad-beam illumination at a low repetition rate (10−50 Hz). Here, we present a method to correct the wavelength-dependent fluence distribution and demonstrate its performance in phantom studies using a conventional limited view/bandwidth hand-held US probe. We adopted analytic fluence models, extending diffusion theory for the case of a pencil beam obliquely incident on an optically homogenous turbid medium, and developed a robust method to estimate fluence attenuation in the medium using PA measurements acquired from multiple fiber-irradiation positions swept at a kHz rate. We conducted comprehensive simulation tests and phantom studies using well-known contrast-agents to validate the reliability of the fluence model and its spectral corrections. Elsevier 2020-05-21 /pmc/articles/PMC7339128/ /pubmed/32670789 http://dx.doi.org/10.1016/j.pacs.2020.100192 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Kim, MinWoo Jeng, Geng-Shi O’Donnell, Matthew Pelivanov, Ivan Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe |
title | Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe |
title_full | Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe |
title_fullStr | Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe |
title_full_unstemmed | Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe |
title_short | Correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe |
title_sort | correction of wavelength-dependent laser fluence in swept-beam spectroscopic photoacoustic imaging with a hand-held probe |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7339128/ https://www.ncbi.nlm.nih.gov/pubmed/32670789 http://dx.doi.org/10.1016/j.pacs.2020.100192 |
work_keys_str_mv | AT kimminwoo correctionofwavelengthdependentlaserfluenceinsweptbeamspectroscopicphotoacousticimagingwithahandheldprobe AT jenggengshi correctionofwavelengthdependentlaserfluenceinsweptbeamspectroscopicphotoacousticimagingwithahandheldprobe AT odonnellmatthew correctionofwavelengthdependentlaserfluenceinsweptbeamspectroscopicphotoacousticimagingwithahandheldprobe AT pelivanovivan correctionofwavelengthdependentlaserfluenceinsweptbeamspectroscopicphotoacousticimagingwithahandheldprobe |