BACKGROUND: Several planning algorithms have been developed for topography-guided custom ablation treatment (T-CAT), but each has its own deficiencies. The purpose of this study is to demonstrate the potential of a novel mutual comparative analysis (MCA) informed by manifest refraction and corneal t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7339473/ https://www.ncbi.nlm.nih.gov/pubmed/32656290 http://dx.doi.org/10.1186/s40662-020-00201-7 |
Sumario: | BACKGROUND: Several planning algorithms have been developed for topography-guided custom ablation treatment (T-CAT), but each has its own deficiencies. The purpose of this study is to demonstrate the potential of a novel mutual comparative analysis (MCA) informed by manifest refraction and corneal topographic data and the patient’s subjective perception in correcting ametropia. METHODS: This retrospective review included patients with significant preoperative differences in the power or axis of astigmatism according to the manifest refraction and corneal topographic data (power > 0.75 D and/or axis > 10°). T-CAT planning was designed using MCA. Follow-ups were conducted for at least 6 months. RESULTS: Seventy-nine patients (121 eyes) were included. The mean preoperative deviation in the astigmatic power and axis were 0.72 ± 0.43 D and 20.18 ± 23.68°, respectively. The average oculus residual astigmatism (ORA) was 0.81 ± 0.32 D (range: 0.08–1.66 D). Six months postoperatively, the mean spherical equivalent refraction was 0.04 ± 0.42 D, and the mean cylinder was − 0.27 ± 0.24 D. The mean efficacy and safety indices were 1.10 and 1.15, respectively. The uncorrected distance visual acuity in 92% of the eyes was the same or better than the corrected distance visual acuity. The angle of error was ±5° in 61% of eyes and ± 15° in 84% of eyes. Residual astigmatism was ≤0.5 D in 91% of eyes. Optical quality and photopic contrast sensitivity did not change significantly (p > 0.05), and the scotopic contrast sensitivity decreased at 3, 6, and 12 cpd (p < 0.05). The vertical coma and horizontal coma of the anterior corneal surface significantly decreased postoperatively but increased during follow-up. CONCLUSIONS: The MCA demonstrated safety, efficacy, accuracy, predictability, and stability and can be used as a complementary and feasible method for T-CAT. |
---|