Cargando…

Mutual comparative analysis: a new topography-guided custom ablation protocol referencing subjective refraction to modify corneal topographic data

BACKGROUND: Several planning algorithms have been developed for topography-guided custom ablation treatment (T-CAT), but each has its own deficiencies. The purpose of this study is to demonstrate the potential of a novel mutual comparative analysis (MCA) informed by manifest refraction and corneal t...

Descripción completa

Detalles Bibliográficos
Autores principales: Cao, Kaiwei, Liu, Lina, Zhang, Tao, Liu, Ting, Bai, Ji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7339473/
https://www.ncbi.nlm.nih.gov/pubmed/32656290
http://dx.doi.org/10.1186/s40662-020-00201-7
_version_ 1783554899285377024
author Cao, Kaiwei
Liu, Lina
Zhang, Tao
Liu, Ting
Bai, Ji
author_facet Cao, Kaiwei
Liu, Lina
Zhang, Tao
Liu, Ting
Bai, Ji
author_sort Cao, Kaiwei
collection PubMed
description BACKGROUND: Several planning algorithms have been developed for topography-guided custom ablation treatment (T-CAT), but each has its own deficiencies. The purpose of this study is to demonstrate the potential of a novel mutual comparative analysis (MCA) informed by manifest refraction and corneal topographic data and the patient’s subjective perception in correcting ametropia. METHODS: This retrospective review included patients with significant preoperative differences in the power or axis of astigmatism according to the manifest refraction and corneal topographic data (power > 0.75 D and/or axis > 10°). T-CAT planning was designed using MCA. Follow-ups were conducted for at least 6 months. RESULTS: Seventy-nine patients (121 eyes) were included. The mean preoperative deviation in the astigmatic power and axis were 0.72 ± 0.43 D and 20.18 ± 23.68°, respectively. The average oculus residual astigmatism (ORA) was 0.81 ± 0.32 D (range: 0.08–1.66 D). Six months postoperatively, the mean spherical equivalent refraction was 0.04 ± 0.42 D, and the mean cylinder was − 0.27 ± 0.24 D. The mean efficacy and safety indices were 1.10 and 1.15, respectively. The uncorrected distance visual acuity in 92% of the eyes was the same or better than the corrected distance visual acuity. The angle of error was ±5° in 61% of eyes and ± 15° in 84% of eyes. Residual astigmatism was ≤0.5 D in 91% of eyes. Optical quality and photopic contrast sensitivity did not change significantly (p > 0.05), and the scotopic contrast sensitivity decreased at 3, 6, and 12 cpd (p < 0.05). The vertical coma and horizontal coma of the anterior corneal surface significantly decreased postoperatively but increased during follow-up. CONCLUSIONS: The MCA demonstrated safety, efficacy, accuracy, predictability, and stability and can be used as a complementary and feasible method for T-CAT.
format Online
Article
Text
id pubmed-7339473
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-73394732020-07-09 Mutual comparative analysis: a new topography-guided custom ablation protocol referencing subjective refraction to modify corneal topographic data Cao, Kaiwei Liu, Lina Zhang, Tao Liu, Ting Bai, Ji Eye Vis (Lond) Research BACKGROUND: Several planning algorithms have been developed for topography-guided custom ablation treatment (T-CAT), but each has its own deficiencies. The purpose of this study is to demonstrate the potential of a novel mutual comparative analysis (MCA) informed by manifest refraction and corneal topographic data and the patient’s subjective perception in correcting ametropia. METHODS: This retrospective review included patients with significant preoperative differences in the power or axis of astigmatism according to the manifest refraction and corneal topographic data (power > 0.75 D and/or axis > 10°). T-CAT planning was designed using MCA. Follow-ups were conducted for at least 6 months. RESULTS: Seventy-nine patients (121 eyes) were included. The mean preoperative deviation in the astigmatic power and axis were 0.72 ± 0.43 D and 20.18 ± 23.68°, respectively. The average oculus residual astigmatism (ORA) was 0.81 ± 0.32 D (range: 0.08–1.66 D). Six months postoperatively, the mean spherical equivalent refraction was 0.04 ± 0.42 D, and the mean cylinder was − 0.27 ± 0.24 D. The mean efficacy and safety indices were 1.10 and 1.15, respectively. The uncorrected distance visual acuity in 92% of the eyes was the same or better than the corrected distance visual acuity. The angle of error was ±5° in 61% of eyes and ± 15° in 84% of eyes. Residual astigmatism was ≤0.5 D in 91% of eyes. Optical quality and photopic contrast sensitivity did not change significantly (p > 0.05), and the scotopic contrast sensitivity decreased at 3, 6, and 12 cpd (p < 0.05). The vertical coma and horizontal coma of the anterior corneal surface significantly decreased postoperatively but increased during follow-up. CONCLUSIONS: The MCA demonstrated safety, efficacy, accuracy, predictability, and stability and can be used as a complementary and feasible method for T-CAT. BioMed Central 2020-07-07 /pmc/articles/PMC7339473/ /pubmed/32656290 http://dx.doi.org/10.1186/s40662-020-00201-7 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Cao, Kaiwei
Liu, Lina
Zhang, Tao
Liu, Ting
Bai, Ji
Mutual comparative analysis: a new topography-guided custom ablation protocol referencing subjective refraction to modify corneal topographic data
title Mutual comparative analysis: a new topography-guided custom ablation protocol referencing subjective refraction to modify corneal topographic data
title_full Mutual comparative analysis: a new topography-guided custom ablation protocol referencing subjective refraction to modify corneal topographic data
title_fullStr Mutual comparative analysis: a new topography-guided custom ablation protocol referencing subjective refraction to modify corneal topographic data
title_full_unstemmed Mutual comparative analysis: a new topography-guided custom ablation protocol referencing subjective refraction to modify corneal topographic data
title_short Mutual comparative analysis: a new topography-guided custom ablation protocol referencing subjective refraction to modify corneal topographic data
title_sort mutual comparative analysis: a new topography-guided custom ablation protocol referencing subjective refraction to modify corneal topographic data
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7339473/
https://www.ncbi.nlm.nih.gov/pubmed/32656290
http://dx.doi.org/10.1186/s40662-020-00201-7
work_keys_str_mv AT caokaiwei mutualcomparativeanalysisanewtopographyguidedcustomablationprotocolreferencingsubjectiverefractiontomodifycornealtopographicdata
AT liulina mutualcomparativeanalysisanewtopographyguidedcustomablationprotocolreferencingsubjectiverefractiontomodifycornealtopographicdata
AT zhangtao mutualcomparativeanalysisanewtopographyguidedcustomablationprotocolreferencingsubjectiverefractiontomodifycornealtopographicdata
AT liuting mutualcomparativeanalysisanewtopographyguidedcustomablationprotocolreferencingsubjectiverefractiontomodifycornealtopographicdata
AT baiji mutualcomparativeanalysisanewtopographyguidedcustomablationprotocolreferencingsubjectiverefractiontomodifycornealtopographicdata