Cargando…

In silico validation of electrocardiographic imaging to reconstruct the endocardial and epicardial repolarization pattern using the equivalent dipole layer source model

The solution of the inverse problem of electrocardiology allows the reconstruction of the spatial distribution of the electrical activity of the heart from the body surface electrocardiogram (electrocardiographic imaging, ECGI). ECGI using the equivalent dipole layer (EDL) model has shown to be accu...

Descripción completa

Detalles Bibliográficos
Autores principales: van der Waal, Jeanne, Meijborg, Veronique, Schuler, Steffen, Coronel, Ruben, Oostendorp, Thom
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7340677/
https://www.ncbi.nlm.nih.gov/pubmed/32474796
http://dx.doi.org/10.1007/s11517-020-02203-y
_version_ 1783555081214361600
author van der Waal, Jeanne
Meijborg, Veronique
Schuler, Steffen
Coronel, Ruben
Oostendorp, Thom
author_facet van der Waal, Jeanne
Meijborg, Veronique
Schuler, Steffen
Coronel, Ruben
Oostendorp, Thom
author_sort van der Waal, Jeanne
collection PubMed
description The solution of the inverse problem of electrocardiology allows the reconstruction of the spatial distribution of the electrical activity of the heart from the body surface electrocardiogram (electrocardiographic imaging, ECGI). ECGI using the equivalent dipole layer (EDL) model has shown to be accurate for cardiac activation times. However, validation of this method to determine repolarization times is lacking. In the present study, we determined the accuracy of the EDL model in reconstructing cardiac repolarization times, and assessed the robustness of the method under less ideal conditions (addition of noise and errors in tissue conductivity). A monodomain model was used to determine the transmembrane potentials in three different excitation-repolarization patterns (sinus beat and ventricular ectopic beats) as the gold standard. These were used to calculate the body surface ECGs using a finite element model. The resulting body surface electrograms (ECGs) were used as input for the EDL-based inverse reconstruction of repolarization times. The reconstructed repolarization times correlated well (COR > 0.85) with the gold standard, with almost no decrease in correlation after adding errors in tissue conductivity of the model or noise to the body surface ECG. Therefore, ECGI using the EDL model allows adequate reconstruction of cardiac repolarization times. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11517-020-02203-y) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-7340677
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-73406772020-07-09 In silico validation of electrocardiographic imaging to reconstruct the endocardial and epicardial repolarization pattern using the equivalent dipole layer source model van der Waal, Jeanne Meijborg, Veronique Schuler, Steffen Coronel, Ruben Oostendorp, Thom Med Biol Eng Comput Original Article The solution of the inverse problem of electrocardiology allows the reconstruction of the spatial distribution of the electrical activity of the heart from the body surface electrocardiogram (electrocardiographic imaging, ECGI). ECGI using the equivalent dipole layer (EDL) model has shown to be accurate for cardiac activation times. However, validation of this method to determine repolarization times is lacking. In the present study, we determined the accuracy of the EDL model in reconstructing cardiac repolarization times, and assessed the robustness of the method under less ideal conditions (addition of noise and errors in tissue conductivity). A monodomain model was used to determine the transmembrane potentials in three different excitation-repolarization patterns (sinus beat and ventricular ectopic beats) as the gold standard. These were used to calculate the body surface ECGs using a finite element model. The resulting body surface electrograms (ECGs) were used as input for the EDL-based inverse reconstruction of repolarization times. The reconstructed repolarization times correlated well (COR > 0.85) with the gold standard, with almost no decrease in correlation after adding errors in tissue conductivity of the model or noise to the body surface ECG. Therefore, ECGI using the EDL model allows adequate reconstruction of cardiac repolarization times. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11517-020-02203-y) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2020-05-31 2020 /pmc/articles/PMC7340677/ /pubmed/32474796 http://dx.doi.org/10.1007/s11517-020-02203-y Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Article
van der Waal, Jeanne
Meijborg, Veronique
Schuler, Steffen
Coronel, Ruben
Oostendorp, Thom
In silico validation of electrocardiographic imaging to reconstruct the endocardial and epicardial repolarization pattern using the equivalent dipole layer source model
title In silico validation of electrocardiographic imaging to reconstruct the endocardial and epicardial repolarization pattern using the equivalent dipole layer source model
title_full In silico validation of electrocardiographic imaging to reconstruct the endocardial and epicardial repolarization pattern using the equivalent dipole layer source model
title_fullStr In silico validation of electrocardiographic imaging to reconstruct the endocardial and epicardial repolarization pattern using the equivalent dipole layer source model
title_full_unstemmed In silico validation of electrocardiographic imaging to reconstruct the endocardial and epicardial repolarization pattern using the equivalent dipole layer source model
title_short In silico validation of electrocardiographic imaging to reconstruct the endocardial and epicardial repolarization pattern using the equivalent dipole layer source model
title_sort in silico validation of electrocardiographic imaging to reconstruct the endocardial and epicardial repolarization pattern using the equivalent dipole layer source model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7340677/
https://www.ncbi.nlm.nih.gov/pubmed/32474796
http://dx.doi.org/10.1007/s11517-020-02203-y
work_keys_str_mv AT vanderwaaljeanne insilicovalidationofelectrocardiographicimagingtoreconstructtheendocardialandepicardialrepolarizationpatternusingtheequivalentdipolelayersourcemodel
AT meijborgveronique insilicovalidationofelectrocardiographicimagingtoreconstructtheendocardialandepicardialrepolarizationpatternusingtheequivalentdipolelayersourcemodel
AT schulersteffen insilicovalidationofelectrocardiographicimagingtoreconstructtheendocardialandepicardialrepolarizationpatternusingtheequivalentdipolelayersourcemodel
AT coronelruben insilicovalidationofelectrocardiographicimagingtoreconstructtheendocardialandepicardialrepolarizationpatternusingtheequivalentdipolelayersourcemodel
AT oostendorpthom insilicovalidationofelectrocardiographicimagingtoreconstructtheendocardialandepicardialrepolarizationpatternusingtheequivalentdipolelayersourcemodel