Cargando…

Is all-inside with suspensory cortical button fixation a superior technique for anterior cruciate ligament reconstruction surgery? A systematic review and meta-analysis

BACKGROUND: To compare the clinical results of all-inside anterior cruciate ligament reconstruction (ACLR) using suspensory cortical button fixation and full tibial tunnel drilling. METHODS: Systematic searches were conducted of published literature up to November 2019 on PubMed, Embase, and Cochran...

Descripción completa

Detalles Bibliográficos
Autores principales: Fu, Chun-Wei, Chen, Wei-Cheng, Lu, Yung-Chang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7341582/
https://www.ncbi.nlm.nih.gov/pubmed/32635920
http://dx.doi.org/10.1186/s12891-020-03471-3
_version_ 1783555267810557952
author Fu, Chun-Wei
Chen, Wei-Cheng
Lu, Yung-Chang
author_facet Fu, Chun-Wei
Chen, Wei-Cheng
Lu, Yung-Chang
author_sort Fu, Chun-Wei
collection PubMed
description BACKGROUND: To compare the clinical results of all-inside anterior cruciate ligament reconstruction (ACLR) using suspensory cortical button fixation and full tibial tunnel drilling. METHODS: Systematic searches were conducted of published literature up to November 2019 on PubMed, Embase, and Cochrane for studies comparing all-inside ACLR using suspensory cortical button fixation and full tibial tunnel ACLR. Two reviewers independently determined eligibility, extracted the outcome data, and assessed the risk of bias of the eligible studies. The clinical outcome and graft reruptures were pooled by using random effects with mean differences and risk ratios for continuous and dichotomous variables, respectively. RESULT: A total of nine studies (five randomized controlled trials and four comparative studies) involving 613 patients were included in the meta-analysis. The postoperative functional outcome, knee laxity measured with arthrometer, and graft reruptures were comparable between patients with all-inside ACLR using suspensory cortical button fixation and full tibial tunnel ACLR. However, a significantly greater thickness of autologous tendon was used and less change in drilling tunnel diameter was noted in patients with suspensory cortical button graft fixation. CONCLUSIONS: All-inside ACLR with suspensory cortical button fixation was not clinically superior to full tibial tunnel ACLR with interference screw fixation in functional outcomes, knee laxity measured with arthrometer, or rerupture rate. However, the advantage of using suspensory cortical button fixation was that a thicker graft could be used for reconstruction, and brought less tibia tunnel widening compared with bioabsorbable interference screw fixation.
format Online
Article
Text
id pubmed-7341582
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-73415822020-07-14 Is all-inside with suspensory cortical button fixation a superior technique for anterior cruciate ligament reconstruction surgery? A systematic review and meta-analysis Fu, Chun-Wei Chen, Wei-Cheng Lu, Yung-Chang BMC Musculoskelet Disord Research Article BACKGROUND: To compare the clinical results of all-inside anterior cruciate ligament reconstruction (ACLR) using suspensory cortical button fixation and full tibial tunnel drilling. METHODS: Systematic searches were conducted of published literature up to November 2019 on PubMed, Embase, and Cochrane for studies comparing all-inside ACLR using suspensory cortical button fixation and full tibial tunnel ACLR. Two reviewers independently determined eligibility, extracted the outcome data, and assessed the risk of bias of the eligible studies. The clinical outcome and graft reruptures were pooled by using random effects with mean differences and risk ratios for continuous and dichotomous variables, respectively. RESULT: A total of nine studies (five randomized controlled trials and four comparative studies) involving 613 patients were included in the meta-analysis. The postoperative functional outcome, knee laxity measured with arthrometer, and graft reruptures were comparable between patients with all-inside ACLR using suspensory cortical button fixation and full tibial tunnel ACLR. However, a significantly greater thickness of autologous tendon was used and less change in drilling tunnel diameter was noted in patients with suspensory cortical button graft fixation. CONCLUSIONS: All-inside ACLR with suspensory cortical button fixation was not clinically superior to full tibial tunnel ACLR with interference screw fixation in functional outcomes, knee laxity measured with arthrometer, or rerupture rate. However, the advantage of using suspensory cortical button fixation was that a thicker graft could be used for reconstruction, and brought less tibia tunnel widening compared with bioabsorbable interference screw fixation. BioMed Central 2020-07-07 /pmc/articles/PMC7341582/ /pubmed/32635920 http://dx.doi.org/10.1186/s12891-020-03471-3 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Fu, Chun-Wei
Chen, Wei-Cheng
Lu, Yung-Chang
Is all-inside with suspensory cortical button fixation a superior technique for anterior cruciate ligament reconstruction surgery? A systematic review and meta-analysis
title Is all-inside with suspensory cortical button fixation a superior technique for anterior cruciate ligament reconstruction surgery? A systematic review and meta-analysis
title_full Is all-inside with suspensory cortical button fixation a superior technique for anterior cruciate ligament reconstruction surgery? A systematic review and meta-analysis
title_fullStr Is all-inside with suspensory cortical button fixation a superior technique for anterior cruciate ligament reconstruction surgery? A systematic review and meta-analysis
title_full_unstemmed Is all-inside with suspensory cortical button fixation a superior technique for anterior cruciate ligament reconstruction surgery? A systematic review and meta-analysis
title_short Is all-inside with suspensory cortical button fixation a superior technique for anterior cruciate ligament reconstruction surgery? A systematic review and meta-analysis
title_sort is all-inside with suspensory cortical button fixation a superior technique for anterior cruciate ligament reconstruction surgery? a systematic review and meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7341582/
https://www.ncbi.nlm.nih.gov/pubmed/32635920
http://dx.doi.org/10.1186/s12891-020-03471-3
work_keys_str_mv AT fuchunwei isallinsidewithsuspensorycorticalbuttonfixationasuperiortechniqueforanteriorcruciateligamentreconstructionsurgeryasystematicreviewandmetaanalysis
AT chenweicheng isallinsidewithsuspensorycorticalbuttonfixationasuperiortechniqueforanteriorcruciateligamentreconstructionsurgeryasystematicreviewandmetaanalysis
AT luyungchang isallinsidewithsuspensorycorticalbuttonfixationasuperiortechniqueforanteriorcruciateligamentreconstructionsurgeryasystematicreviewandmetaanalysis