Cargando…

Double-quencher probes improve detection sensitivity toward Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in a reverse-transcription polymerase chain reaction (RT-PCR) assay

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) which emerged in the city of Wuhan, Hubei Province, China, has spread worldwide and is threatening human life. The detection of SARS-CoV-2 is critical for preventing new outbreaks, curbing disease spread, and managing patients....

Descripción completa

Detalles Bibliográficos
Autores principales: Hirotsu, Yosuke, Mochizuki, Hitoshi, Omata, Masao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7341737/
https://www.ncbi.nlm.nih.gov/pubmed/32650037
http://dx.doi.org/10.1016/j.jviromet.2020.113926
_version_ 1783555295836897280
author Hirotsu, Yosuke
Mochizuki, Hitoshi
Omata, Masao
author_facet Hirotsu, Yosuke
Mochizuki, Hitoshi
Omata, Masao
author_sort Hirotsu, Yosuke
collection PubMed
description BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) which emerged in the city of Wuhan, Hubei Province, China, has spread worldwide and is threatening human life. The detection of SARS-CoV-2 is critical for preventing new outbreaks, curbing disease spread, and managing patients. Currently, a reverse-transcription polymerase chain reaction (RT-PCR) assay is used to detect the virus in clinical laboratories. However, although this assay is considered to have high specificity, its sensitivity is reportedly as low as 60–70 %. Improved sensitivity is, therefore, urgently required. METHODS: We used the primers and single-quencher probes recommended by the CDC (N1, N2 and N3) in the USA and the NIID (N1 and N2) in Japan. In addition, we designed double-quencher probes according to the virus sequence provided by the NIID to develop a further assay (termed the YCH assay [N1 and N2]). Using these assays, we conducted RT-PCR with serially diluted DNA positive controls to assess and compare the detection sensitivity of the three assays. Furthermore, 66 nasopharyngeal swabs were tested to determine the diagnostic performances. RESULTS: The threshold cycle (Ct) value of the RT-PCR was relatively low for the CDC and YCH assays compared with the NIID assay. Serial dilution assays showed that both the CDC and YCH assays could detect low copy numbers of the DNA positive control. The background fluorescence signal at the baseline was lower for the YCH assay compared with the NIID assay. We assessed the diagnostic performance between single- (NIID) and double-quencher (YCH) probes using 66 nasopharyngeal swabs. When the results of YCH-N2 assay were used as a reference, each assay detected SARS-CoV-2 with positive percent agreements of 56 % for NIID-N1, 61 % for YCH-N1, and 94 % for NIID-N2, and 100 % negative percent agreements for NIID-N1, YCH-N1 and NIID-N2. CONCLUSION: Double-quencher probes decreased the background fluorescence and improved the detection sensitivity of RT-PCR for SARS-CoV-2.
format Online
Article
Text
id pubmed-7341737
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-73417372020-07-08 Double-quencher probes improve detection sensitivity toward Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in a reverse-transcription polymerase chain reaction (RT-PCR) assay Hirotsu, Yosuke Mochizuki, Hitoshi Omata, Masao J Virol Methods Article BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) which emerged in the city of Wuhan, Hubei Province, China, has spread worldwide and is threatening human life. The detection of SARS-CoV-2 is critical for preventing new outbreaks, curbing disease spread, and managing patients. Currently, a reverse-transcription polymerase chain reaction (RT-PCR) assay is used to detect the virus in clinical laboratories. However, although this assay is considered to have high specificity, its sensitivity is reportedly as low as 60–70 %. Improved sensitivity is, therefore, urgently required. METHODS: We used the primers and single-quencher probes recommended by the CDC (N1, N2 and N3) in the USA and the NIID (N1 and N2) in Japan. In addition, we designed double-quencher probes according to the virus sequence provided by the NIID to develop a further assay (termed the YCH assay [N1 and N2]). Using these assays, we conducted RT-PCR with serially diluted DNA positive controls to assess and compare the detection sensitivity of the three assays. Furthermore, 66 nasopharyngeal swabs were tested to determine the diagnostic performances. RESULTS: The threshold cycle (Ct) value of the RT-PCR was relatively low for the CDC and YCH assays compared with the NIID assay. Serial dilution assays showed that both the CDC and YCH assays could detect low copy numbers of the DNA positive control. The background fluorescence signal at the baseline was lower for the YCH assay compared with the NIID assay. We assessed the diagnostic performance between single- (NIID) and double-quencher (YCH) probes using 66 nasopharyngeal swabs. When the results of YCH-N2 assay were used as a reference, each assay detected SARS-CoV-2 with positive percent agreements of 56 % for NIID-N1, 61 % for YCH-N1, and 94 % for NIID-N2, and 100 % negative percent agreements for NIID-N1, YCH-N1 and NIID-N2. CONCLUSION: Double-quencher probes decreased the background fluorescence and improved the detection sensitivity of RT-PCR for SARS-CoV-2. Elsevier B.V. 2020-10 2020-07-07 /pmc/articles/PMC7341737/ /pubmed/32650037 http://dx.doi.org/10.1016/j.jviromet.2020.113926 Text en © 2020 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Hirotsu, Yosuke
Mochizuki, Hitoshi
Omata, Masao
Double-quencher probes improve detection sensitivity toward Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in a reverse-transcription polymerase chain reaction (RT-PCR) assay
title Double-quencher probes improve detection sensitivity toward Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in a reverse-transcription polymerase chain reaction (RT-PCR) assay
title_full Double-quencher probes improve detection sensitivity toward Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in a reverse-transcription polymerase chain reaction (RT-PCR) assay
title_fullStr Double-quencher probes improve detection sensitivity toward Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in a reverse-transcription polymerase chain reaction (RT-PCR) assay
title_full_unstemmed Double-quencher probes improve detection sensitivity toward Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in a reverse-transcription polymerase chain reaction (RT-PCR) assay
title_short Double-quencher probes improve detection sensitivity toward Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in a reverse-transcription polymerase chain reaction (RT-PCR) assay
title_sort double-quencher probes improve detection sensitivity toward severe acute respiratory syndrome coronavirus 2 (sars-cov-2) in a reverse-transcription polymerase chain reaction (rt-pcr) assay
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7341737/
https://www.ncbi.nlm.nih.gov/pubmed/32650037
http://dx.doi.org/10.1016/j.jviromet.2020.113926
work_keys_str_mv AT hirotsuyosuke doublequencherprobesimprovedetectionsensitivitytowardsevereacuterespiratorysyndromecoronavirus2sarscov2inareversetranscriptionpolymerasechainreactionrtpcrassay
AT mochizukihitoshi doublequencherprobesimprovedetectionsensitivitytowardsevereacuterespiratorysyndromecoronavirus2sarscov2inareversetranscriptionpolymerasechainreactionrtpcrassay
AT omatamasao doublequencherprobesimprovedetectionsensitivitytowardsevereacuterespiratorysyndromecoronavirus2sarscov2inareversetranscriptionpolymerasechainreactionrtpcrassay