Cargando…
Characterisation of a hand-held CZT-based gamma camera for (177)Lu imaging
BACKGROUND: Currently, hand-held gamma cameras are being developed for (99m)Tc imaging, mainly for sentinel lymph node detection. These cameras offer advantages, such as mobility and ease of access, and may be useful also for other applications such as biokinetic studies in animals or for imaging of...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7343677/ https://www.ncbi.nlm.nih.gov/pubmed/32642884 http://dx.doi.org/10.1186/s40658-020-00313-y |
Sumario: | BACKGROUND: Currently, hand-held gamma cameras are being developed for (99m)Tc imaging, mainly for sentinel lymph node detection. These cameras offer advantages, such as mobility and ease of access, and may be useful also for other applications such as biokinetic studies in animals or for imaging of small, superficial structures in patients. In this work, the suitability of a CZT-based hand-held camera for (177)Lu imaging is investigated. The energy response of CZT-based detectors combined with the multiple photon emissions of (177)Lu poses new challenges compared to (99m)Tc imaging, and a thorough camera characterisation is thus warranted. METHODS: Three collimators (LEHR, LEHS, and MEGP) and three energy windows (55 keV, 113 keV, and 208 keV) are investigated. Characterised camera properties include the system spatial resolution, energy resolution, sensitivity, image uniformity, septal penetration, and temperature dependence. Characterisations are made starting from NEMA guidelines when applicable, with adjustments made when required. The applicability of the camera is demonstrated by imaging of a superficially located tumour in a patient undergoing [(177) Lu]Lu-DOTA-TATE therapy. RESULTS: Overall, the results are encouraging. Compared to a conventional gamma camera, the hand-held camera generally has a higher sensitivity for a given collimator. For source-collimator distances below 3 cm, the spatial resolution FWHM is within 6 mm for the LEHR and MEGP collimators. Before uniformity correction, the central field-of-view integral uniformity shows best results for the 113-keV window, with values obtained between 11 and 14%. The corresponding values after uniformity correction are within 3%. Effects of septal penetration are observed but are manageable with a proper combination of collimator and energy window setting. Septal penetration and collimator scatter not only affect the 208-keV window but also contribute with counts in lower windows due to energy-tailing effects. The patient study revealed non-uniform uptake patterns in a region that appeared uniform in a conventional gamma camera image. CONCLUSIONS: The results show that the hand-held camera can be used for (177)Lu imaging. A 113-keV energy window combined with LEHR or MEGP collimators provides the best image system characteristics. |
---|