Cargando…

Intraoperative Sphenoid Sinus Volume Measurement as an Alternative Technique to Intraoperative Computer Tomography

Isolated sphenoid sinus disease (ISSD) is where there is a group of pathologies characterized by inflammation in one or both sphenoid sinuses. Although computer tomography (CT)-based 3D reconstruction remains the gold standard among noninvasive approaches to ISSD diagnostics, no standardized techniq...

Descripción completa

Detalles Bibliográficos
Autores principales: Karpishchenko, Sergei, Arustamyan, Irina, Stancheva, Olga, Sharko, Kirill, Kaplun, Dmitry, Bogachev, Mikhail I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7344634/
https://www.ncbi.nlm.nih.gov/pubmed/32481520
http://dx.doi.org/10.3390/diagnostics10060350
_version_ 1783555989970092032
author Karpishchenko, Sergei
Arustamyan, Irina
Stancheva, Olga
Sharko, Kirill
Kaplun, Dmitry
Bogachev, Mikhail I.
author_facet Karpishchenko, Sergei
Arustamyan, Irina
Stancheva, Olga
Sharko, Kirill
Kaplun, Dmitry
Bogachev, Mikhail I.
author_sort Karpishchenko, Sergei
collection PubMed
description Isolated sphenoid sinus disease (ISSD) is where there is a group of pathologies characterized by inflammation in one or both sphenoid sinuses. Although computer tomography (CT)-based 3D reconstruction remains the gold standard among noninvasive approaches to ISSD diagnostics, no standardized techniques for direct intraoperative measurements of the sphenoid sinus volume in ISSD patients have been documented. We suggest a novel technique for the intraoperative measurement of the sphenoid sinus volume. Our technique is based on filling the sinus with 0.01% methylene blue solution after an endoscopic endonasal sphenoidotomy. The proposed technique was applied to 40 ISSD patients during surgery. Obtained intraoperative measurements were compared to noninvasive measurements from 3D reconstructions based on preoperative CT scans. Our results demonstrated that the obtained measurements did not exhibit significant differences exceeding 0.4 cm(3), with CT-scan-based measurements in 39 out of 40 cases (p < 10(−6), Wilcoxon sign-rank nonparametric test), thus confirming the accuracy of the proposed technique. Disagreements between direct intraoperative and CT-based measurements in a single case have been attributed to the presence of remaining pathological masses in the sinus, which was further confirmed during the secondary check of the operated sinus. Accordingly, we suggest that the agreement between the CT-based and intraoperative volume measurements can be used as an indicator of the successful elimination of all pathological masses from the sinus without having to perform an adequate exposure of the entire sphenoid sinus to reduce intraoperative bleeding. The proposed technique is accurate and does not require the involvement of specialized intraoperative CT scanners and avoids additional radiation exposure for the patient during an additional postoperation CT scan to confirm the success of the surgery.
format Online
Article
Text
id pubmed-7344634
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73446342020-07-09 Intraoperative Sphenoid Sinus Volume Measurement as an Alternative Technique to Intraoperative Computer Tomography Karpishchenko, Sergei Arustamyan, Irina Stancheva, Olga Sharko, Kirill Kaplun, Dmitry Bogachev, Mikhail I. Diagnostics (Basel) Article Isolated sphenoid sinus disease (ISSD) is where there is a group of pathologies characterized by inflammation in one or both sphenoid sinuses. Although computer tomography (CT)-based 3D reconstruction remains the gold standard among noninvasive approaches to ISSD diagnostics, no standardized techniques for direct intraoperative measurements of the sphenoid sinus volume in ISSD patients have been documented. We suggest a novel technique for the intraoperative measurement of the sphenoid sinus volume. Our technique is based on filling the sinus with 0.01% methylene blue solution after an endoscopic endonasal sphenoidotomy. The proposed technique was applied to 40 ISSD patients during surgery. Obtained intraoperative measurements were compared to noninvasive measurements from 3D reconstructions based on preoperative CT scans. Our results demonstrated that the obtained measurements did not exhibit significant differences exceeding 0.4 cm(3), with CT-scan-based measurements in 39 out of 40 cases (p < 10(−6), Wilcoxon sign-rank nonparametric test), thus confirming the accuracy of the proposed technique. Disagreements between direct intraoperative and CT-based measurements in a single case have been attributed to the presence of remaining pathological masses in the sinus, which was further confirmed during the secondary check of the operated sinus. Accordingly, we suggest that the agreement between the CT-based and intraoperative volume measurements can be used as an indicator of the successful elimination of all pathological masses from the sinus without having to perform an adequate exposure of the entire sphenoid sinus to reduce intraoperative bleeding. The proposed technique is accurate and does not require the involvement of specialized intraoperative CT scanners and avoids additional radiation exposure for the patient during an additional postoperation CT scan to confirm the success of the surgery. MDPI 2020-05-28 /pmc/articles/PMC7344634/ /pubmed/32481520 http://dx.doi.org/10.3390/diagnostics10060350 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Karpishchenko, Sergei
Arustamyan, Irina
Stancheva, Olga
Sharko, Kirill
Kaplun, Dmitry
Bogachev, Mikhail I.
Intraoperative Sphenoid Sinus Volume Measurement as an Alternative Technique to Intraoperative Computer Tomography
title Intraoperative Sphenoid Sinus Volume Measurement as an Alternative Technique to Intraoperative Computer Tomography
title_full Intraoperative Sphenoid Sinus Volume Measurement as an Alternative Technique to Intraoperative Computer Tomography
title_fullStr Intraoperative Sphenoid Sinus Volume Measurement as an Alternative Technique to Intraoperative Computer Tomography
title_full_unstemmed Intraoperative Sphenoid Sinus Volume Measurement as an Alternative Technique to Intraoperative Computer Tomography
title_short Intraoperative Sphenoid Sinus Volume Measurement as an Alternative Technique to Intraoperative Computer Tomography
title_sort intraoperative sphenoid sinus volume measurement as an alternative technique to intraoperative computer tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7344634/
https://www.ncbi.nlm.nih.gov/pubmed/32481520
http://dx.doi.org/10.3390/diagnostics10060350
work_keys_str_mv AT karpishchenkosergei intraoperativesphenoidsinusvolumemeasurementasanalternativetechniquetointraoperativecomputertomography
AT arustamyanirina intraoperativesphenoidsinusvolumemeasurementasanalternativetechniquetointraoperativecomputertomography
AT stanchevaolga intraoperativesphenoidsinusvolumemeasurementasanalternativetechniquetointraoperativecomputertomography
AT sharkokirill intraoperativesphenoidsinusvolumemeasurementasanalternativetechniquetointraoperativecomputertomography
AT kaplundmitry intraoperativesphenoidsinusvolumemeasurementasanalternativetechniquetointraoperativecomputertomography
AT bogachevmikhaili intraoperativesphenoidsinusvolumemeasurementasanalternativetechniquetointraoperativecomputertomography