Cargando…

Heart Rate Monitor Instead of Ablation? Atrioventricular Nodal Re-Entrant Tachycardia in a Leisure-Time Triathlete: 6-Year Follow-Up

This study describes a triathlete with effort-provoked atrioventricular nodal re-entrant tachycardia (AVNRT), diagnosed six years ago, who ineffectively controlled his training load via heart-rate monitors (HRM) to avoid tachyarrhythmia. Of the 1800 workouts recorded for 6 years on HRMs, we found 45...

Descripción completa

Detalles Bibliográficos
Autor principal: Gajda, Robert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7344650/
https://www.ncbi.nlm.nih.gov/pubmed/32532026
http://dx.doi.org/10.3390/diagnostics10060391
_version_ 1783555994010255360
author Gajda, Robert
author_facet Gajda, Robert
author_sort Gajda, Robert
collection PubMed
description This study describes a triathlete with effort-provoked atrioventricular nodal re-entrant tachycardia (AVNRT), diagnosed six years ago, who ineffectively controlled his training load via heart-rate monitors (HRM) to avoid tachyarrhythmia. Of the 1800 workouts recorded for 6 years on HRMs, we found 45 tachyarrhythmias, which forced the athlete to stop exercising. In three of them, AVNRT was simultaneously confirmed by a Holter electrocardiogram (ECG). Tachyarrhythmias occurred in different phases (after the 2nd–131st minutes, median: 29th minute) and frequencies (3–8, average: 6.5 times/year), characterized by different heart rates (HR) (150–227 beats per minute (bpm), median: 187 bpm) and duration (10–186, median: 40 s). Tachyarrhythmia appeared both unexpectedly in the initial stages of training as well as quite predictably during prolonged submaximal exercise—but without rigid rules. Tachyarrhythmias during cycling were more intensive (200 vs. 162 bpm, p = 0.0004) and occurred later (41 vs. 10 min, p = 0.0007) than those during running (only one noticed but not recorded during swimming). We noticed a tendency (p = 0.1748) towards the decreasing duration time of tachycardias (2014–2015: 60 s; 2016–2017: 50 s; 2018–later: 37 s). The amateur athlete tolerated the tachycardic episodes quite well and the ECG test and echocardiography were normal. In the studied case, the HRM was a useful diagnostic tool for detecting symptomatic arrhythmia; however, no change in the amount, phase of training, speed, or duration of exercise-stimulated tachyarrhythmia was observed.
format Online
Article
Text
id pubmed-7344650
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73446502020-07-09 Heart Rate Monitor Instead of Ablation? Atrioventricular Nodal Re-Entrant Tachycardia in a Leisure-Time Triathlete: 6-Year Follow-Up Gajda, Robert Diagnostics (Basel) Case Report This study describes a triathlete with effort-provoked atrioventricular nodal re-entrant tachycardia (AVNRT), diagnosed six years ago, who ineffectively controlled his training load via heart-rate monitors (HRM) to avoid tachyarrhythmia. Of the 1800 workouts recorded for 6 years on HRMs, we found 45 tachyarrhythmias, which forced the athlete to stop exercising. In three of them, AVNRT was simultaneously confirmed by a Holter electrocardiogram (ECG). Tachyarrhythmias occurred in different phases (after the 2nd–131st minutes, median: 29th minute) and frequencies (3–8, average: 6.5 times/year), characterized by different heart rates (HR) (150–227 beats per minute (bpm), median: 187 bpm) and duration (10–186, median: 40 s). Tachyarrhythmia appeared both unexpectedly in the initial stages of training as well as quite predictably during prolonged submaximal exercise—but without rigid rules. Tachyarrhythmias during cycling were more intensive (200 vs. 162 bpm, p = 0.0004) and occurred later (41 vs. 10 min, p = 0.0007) than those during running (only one noticed but not recorded during swimming). We noticed a tendency (p = 0.1748) towards the decreasing duration time of tachycardias (2014–2015: 60 s; 2016–2017: 50 s; 2018–later: 37 s). The amateur athlete tolerated the tachycardic episodes quite well and the ECG test and echocardiography were normal. In the studied case, the HRM was a useful diagnostic tool for detecting symptomatic arrhythmia; however, no change in the amount, phase of training, speed, or duration of exercise-stimulated tachyarrhythmia was observed. MDPI 2020-06-10 /pmc/articles/PMC7344650/ /pubmed/32532026 http://dx.doi.org/10.3390/diagnostics10060391 Text en © 2020 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Case Report
Gajda, Robert
Heart Rate Monitor Instead of Ablation? Atrioventricular Nodal Re-Entrant Tachycardia in a Leisure-Time Triathlete: 6-Year Follow-Up
title Heart Rate Monitor Instead of Ablation? Atrioventricular Nodal Re-Entrant Tachycardia in a Leisure-Time Triathlete: 6-Year Follow-Up
title_full Heart Rate Monitor Instead of Ablation? Atrioventricular Nodal Re-Entrant Tachycardia in a Leisure-Time Triathlete: 6-Year Follow-Up
title_fullStr Heart Rate Monitor Instead of Ablation? Atrioventricular Nodal Re-Entrant Tachycardia in a Leisure-Time Triathlete: 6-Year Follow-Up
title_full_unstemmed Heart Rate Monitor Instead of Ablation? Atrioventricular Nodal Re-Entrant Tachycardia in a Leisure-Time Triathlete: 6-Year Follow-Up
title_short Heart Rate Monitor Instead of Ablation? Atrioventricular Nodal Re-Entrant Tachycardia in a Leisure-Time Triathlete: 6-Year Follow-Up
title_sort heart rate monitor instead of ablation? atrioventricular nodal re-entrant tachycardia in a leisure-time triathlete: 6-year follow-up
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7344650/
https://www.ncbi.nlm.nih.gov/pubmed/32532026
http://dx.doi.org/10.3390/diagnostics10060391
work_keys_str_mv AT gajdarobert heartratemonitorinsteadofablationatrioventricularnodalreentranttachycardiainaleisuretimetriathlete6yearfollowup