Cargando…

One Step before 3D Printing—Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique

The accuracy of 3D reconstructions of the craniomaxillofacial region using cone beam computed tomography (CBCT) is important for the morphological evaluation of specific anatomical structures. Moreover, an accurate segmentation process is fundamental for the physical reconstruction of the anatomy (3...

Descripción completa

Detalles Bibliográficos
Autores principales: Lo Giudice, Antonino, Ronsivalle, Vincenzo, Grippaudo, Cristina, Lucchese, Alessandra, Muraglie, Simone, Lagravère, Manuel O., Isola, Gaetano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7345160/
https://www.ncbi.nlm.nih.gov/pubmed/32575875
http://dx.doi.org/10.3390/ma13122798
_version_ 1783556115866320896
author Lo Giudice, Antonino
Ronsivalle, Vincenzo
Grippaudo, Cristina
Lucchese, Alessandra
Muraglie, Simone
Lagravère, Manuel O.
Isola, Gaetano
author_facet Lo Giudice, Antonino
Ronsivalle, Vincenzo
Grippaudo, Cristina
Lucchese, Alessandra
Muraglie, Simone
Lagravère, Manuel O.
Isola, Gaetano
author_sort Lo Giudice, Antonino
collection PubMed
description The accuracy of 3D reconstructions of the craniomaxillofacial region using cone beam computed tomography (CBCT) is important for the morphological evaluation of specific anatomical structures. Moreover, an accurate segmentation process is fundamental for the physical reconstruction of the anatomy (3D printing) when a preliminary simulation of the therapy is required. In this regard, the objective of this study is to evaluate the accuracy of four different types of software for the semiautomatic segmentation of the mandibular jaw compared to manual segmentation, used as a gold standard. Twenty cone beam computed tomography (CBCT) with a manual approach (Mimics) and a semi-automatic approach (Invesalius, ITK-Snap, Dolphin 3D, Slicer 3D) were selected for the segmentation of the mandible in the present study. The accuracy of semi-automatic segmentation was evaluated: (1) by comparing the mandibular volumes obtained with semi-automatic 3D rendering and manual segmentation and (2) by deviation analysis between the two mandibular models. An analysis of variance (ANOVA) was used to evaluate differences in mandibular volumetric recordings and for a deviation analysis among the different software types used. Linear regression was also performed between manual and semi-automatic methods. No significant differences were found in the total volumes among the obtained 3D mandibular models (Mimics = 40.85 cm(3), ITK-Snap = 40.81 cm(3), Invesalius = 40.04 cm(3), Dolphin 3D = 42.03 cm(3), Slicer 3D = 40.58 cm(3)). High correlations were found between the semi-automatic segmentation and manual segmentation approach, with R coefficients ranging from 0,960 to 0,992. According to the deviation analysis, the mandibular models obtained with ITK-Snap showed the highest matching percentage (Tolerance A = 88.44%, Tolerance B = 97.30%), while those obtained with Dolphin 3D showed the lowest matching percentage (Tolerance A = 60.01%, Tolerance B = 87.76%) (p < 0.05). Colour-coded maps showed that the area of greatest mismatch between semi-automatic and manual segmentation was the condylar region and the region proximate to the dental roots. Despite the fact that the semi-automatic segmentation of the mandible showed, in general, high reliability and high correlation with the manual segmentation, caution should be taken when evaluating the morphological and dimensional characteristics of the condyles either on CBCT-derived digital models or physical models (3D printing).
format Online
Article
Text
id pubmed-7345160
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73451602020-07-09 One Step before 3D Printing—Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique Lo Giudice, Antonino Ronsivalle, Vincenzo Grippaudo, Cristina Lucchese, Alessandra Muraglie, Simone Lagravère, Manuel O. Isola, Gaetano Materials (Basel) Article The accuracy of 3D reconstructions of the craniomaxillofacial region using cone beam computed tomography (CBCT) is important for the morphological evaluation of specific anatomical structures. Moreover, an accurate segmentation process is fundamental for the physical reconstruction of the anatomy (3D printing) when a preliminary simulation of the therapy is required. In this regard, the objective of this study is to evaluate the accuracy of four different types of software for the semiautomatic segmentation of the mandibular jaw compared to manual segmentation, used as a gold standard. Twenty cone beam computed tomography (CBCT) with a manual approach (Mimics) and a semi-automatic approach (Invesalius, ITK-Snap, Dolphin 3D, Slicer 3D) were selected for the segmentation of the mandible in the present study. The accuracy of semi-automatic segmentation was evaluated: (1) by comparing the mandibular volumes obtained with semi-automatic 3D rendering and manual segmentation and (2) by deviation analysis between the two mandibular models. An analysis of variance (ANOVA) was used to evaluate differences in mandibular volumetric recordings and for a deviation analysis among the different software types used. Linear regression was also performed between manual and semi-automatic methods. No significant differences were found in the total volumes among the obtained 3D mandibular models (Mimics = 40.85 cm(3), ITK-Snap = 40.81 cm(3), Invesalius = 40.04 cm(3), Dolphin 3D = 42.03 cm(3), Slicer 3D = 40.58 cm(3)). High correlations were found between the semi-automatic segmentation and manual segmentation approach, with R coefficients ranging from 0,960 to 0,992. According to the deviation analysis, the mandibular models obtained with ITK-Snap showed the highest matching percentage (Tolerance A = 88.44%, Tolerance B = 97.30%), while those obtained with Dolphin 3D showed the lowest matching percentage (Tolerance A = 60.01%, Tolerance B = 87.76%) (p < 0.05). Colour-coded maps showed that the area of greatest mismatch between semi-automatic and manual segmentation was the condylar region and the region proximate to the dental roots. Despite the fact that the semi-automatic segmentation of the mandible showed, in general, high reliability and high correlation with the manual segmentation, caution should be taken when evaluating the morphological and dimensional characteristics of the condyles either on CBCT-derived digital models or physical models (3D printing). MDPI 2020-06-21 /pmc/articles/PMC7345160/ /pubmed/32575875 http://dx.doi.org/10.3390/ma13122798 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lo Giudice, Antonino
Ronsivalle, Vincenzo
Grippaudo, Cristina
Lucchese, Alessandra
Muraglie, Simone
Lagravère, Manuel O.
Isola, Gaetano
One Step before 3D Printing—Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique
title One Step before 3D Printing—Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique
title_full One Step before 3D Printing—Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique
title_fullStr One Step before 3D Printing—Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique
title_full_unstemmed One Step before 3D Printing—Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique
title_short One Step before 3D Printing—Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique
title_sort one step before 3d printing—evaluation of imaging software accuracy for 3-dimensional analysis of the mandible: a comparative study using a surface-to-surface matching technique
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7345160/
https://www.ncbi.nlm.nih.gov/pubmed/32575875
http://dx.doi.org/10.3390/ma13122798
work_keys_str_mv AT logiudiceantonino onestepbefore3dprintingevaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibleacomparativestudyusingasurfacetosurfacematchingtechnique
AT ronsivallevincenzo onestepbefore3dprintingevaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibleacomparativestudyusingasurfacetosurfacematchingtechnique
AT grippaudocristina onestepbefore3dprintingevaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibleacomparativestudyusingasurfacetosurfacematchingtechnique
AT lucchesealessandra onestepbefore3dprintingevaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibleacomparativestudyusingasurfacetosurfacematchingtechnique
AT muragliesimone onestepbefore3dprintingevaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibleacomparativestudyusingasurfacetosurfacematchingtechnique
AT lagraveremanuelo onestepbefore3dprintingevaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibleacomparativestudyusingasurfacetosurfacematchingtechnique
AT isolagaetano onestepbefore3dprintingevaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibleacomparativestudyusingasurfacetosurfacematchingtechnique