Cargando…

Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study

Statement of problem: Current techniques for repairing porcelain-chipped restorations have several limitations. With advances in CAD/CAM technology, the combination of resin cements and high-strength ceramic materials might offer new options for repairing the chipping of veneering ceramic. Purpose:...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumchai, Hattanas, Juntavee, Patrapan, Sun, Arthur F., Nathanson, Dan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7345289/
https://www.ncbi.nlm.nih.gov/pubmed/32349281
http://dx.doi.org/10.3390/dj8020037
_version_ 1783556146462720000
author Kumchai, Hattanas
Juntavee, Patrapan
Sun, Arthur F.
Nathanson, Dan
author_facet Kumchai, Hattanas
Juntavee, Patrapan
Sun, Arthur F.
Nathanson, Dan
author_sort Kumchai, Hattanas
collection PubMed
description Statement of problem: Current techniques for repairing porcelain-chipped restorations have several limitations. With advances in CAD/CAM technology, the combination of resin cements and high-strength ceramic materials might offer new options for repairing the chipping of veneering ceramic. Purpose: The purpose of this study is to compare the load-to-failure of veneered zirconia crowns repaired by different materials. Material and Methods: Veneered zirconia crowns were made on aluminum dies (n = 10/group). Feldspathic porcelain (Vita VM9, Vident) was applied to the zirconia coping (Vita In-Ceram YZ, Vident) in a cylindrical shape (Ø 10.5 mm, height 7.5 mm). A bevel cut on the porcelain veneer (45 degree, 3 mm width) was made at one side of each crown to simulate porcelain chipping. The crowns were then divided into four different groups according to the repair materials: 1. Conventional resin composite (A; Tetric EvoCeram, Ivoclar Vivadent); 2. Flowable resin composite (B; G-aenial Universal Flo, GC america); 3. CAD/CAM milled feldspathic ceramic (C; Vita Trilux Forte, Vident); 4. CAD/CAM milled lithium disilicate glass-ceramic (D; IPS e.max CAD, Ivoclar Vivadent). Resin cement (Multilink Automix, Ivoclar Vivadent) was used to cement the CAD/CAM ceramic materials to the beveled crowns. Each crown underwent 5000 cycles of thermocycling. The strength test was performed on an Instron universal testing machine by loading force on the center of repaired part to record load-to-failure. Data were analyzed by ANOVA and Tukey HSD post-hoc tests (α = 0.05). Results: Mean loads-to-failure (in Newton +/− SD) of repaired veneered zirconia crowns were: Gr. A: 660.0 ± 200.5; Gr. B: 681.7 ± 175.9; Gr. C: 1236.0 ± 188.8; Gr. D: 1536.3 ± 286.1. Catastrophic failure was the most dominant failure mode in every group. Few specimens exhibited cohesive failure. Only one specimen in group D had adhesive failure. Conclusions: Within the limitation of the study, veneered zirconia crowns repaired with CAD/CAM ceramic materials have significantly higher load-to-failure than veneered crowns repaired with resin composite (p ≤ 0.05). Clinical Implications: Traditionally, porcelain-chipped restorations are often repaired with resin composite and bonding technique. Repairing chipped porcelain with CAD/CAM ceramics fitting the fractured parts can be alternative option with potential advantages. More well-designed studies are necessary to justify this novel repair technique.
format Online
Article
Text
id pubmed-7345289
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73452892020-07-09 Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study Kumchai, Hattanas Juntavee, Patrapan Sun, Arthur F. Nathanson, Dan Dent J (Basel) Article Statement of problem: Current techniques for repairing porcelain-chipped restorations have several limitations. With advances in CAD/CAM technology, the combination of resin cements and high-strength ceramic materials might offer new options for repairing the chipping of veneering ceramic. Purpose: The purpose of this study is to compare the load-to-failure of veneered zirconia crowns repaired by different materials. Material and Methods: Veneered zirconia crowns were made on aluminum dies (n = 10/group). Feldspathic porcelain (Vita VM9, Vident) was applied to the zirconia coping (Vita In-Ceram YZ, Vident) in a cylindrical shape (Ø 10.5 mm, height 7.5 mm). A bevel cut on the porcelain veneer (45 degree, 3 mm width) was made at one side of each crown to simulate porcelain chipping. The crowns were then divided into four different groups according to the repair materials: 1. Conventional resin composite (A; Tetric EvoCeram, Ivoclar Vivadent); 2. Flowable resin composite (B; G-aenial Universal Flo, GC america); 3. CAD/CAM milled feldspathic ceramic (C; Vita Trilux Forte, Vident); 4. CAD/CAM milled lithium disilicate glass-ceramic (D; IPS e.max CAD, Ivoclar Vivadent). Resin cement (Multilink Automix, Ivoclar Vivadent) was used to cement the CAD/CAM ceramic materials to the beveled crowns. Each crown underwent 5000 cycles of thermocycling. The strength test was performed on an Instron universal testing machine by loading force on the center of repaired part to record load-to-failure. Data were analyzed by ANOVA and Tukey HSD post-hoc tests (α = 0.05). Results: Mean loads-to-failure (in Newton +/− SD) of repaired veneered zirconia crowns were: Gr. A: 660.0 ± 200.5; Gr. B: 681.7 ± 175.9; Gr. C: 1236.0 ± 188.8; Gr. D: 1536.3 ± 286.1. Catastrophic failure was the most dominant failure mode in every group. Few specimens exhibited cohesive failure. Only one specimen in group D had adhesive failure. Conclusions: Within the limitation of the study, veneered zirconia crowns repaired with CAD/CAM ceramic materials have significantly higher load-to-failure than veneered crowns repaired with resin composite (p ≤ 0.05). Clinical Implications: Traditionally, porcelain-chipped restorations are often repaired with resin composite and bonding technique. Repairing chipped porcelain with CAD/CAM ceramics fitting the fractured parts can be alternative option with potential advantages. More well-designed studies are necessary to justify this novel repair technique. MDPI 2020-04-27 /pmc/articles/PMC7345289/ /pubmed/32349281 http://dx.doi.org/10.3390/dj8020037 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kumchai, Hattanas
Juntavee, Patrapan
Sun, Arthur F.
Nathanson, Dan
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
title Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
title_full Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
title_fullStr Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
title_full_unstemmed Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
title_short Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
title_sort comparing the repair of veneered zirconia crowns with ceramic or composite resin: an in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7345289/
https://www.ncbi.nlm.nih.gov/pubmed/32349281
http://dx.doi.org/10.3390/dj8020037
work_keys_str_mv AT kumchaihattanas comparingtherepairofveneeredzirconiacrownswithceramicorcompositeresinaninvitrostudy
AT juntaveepatrapan comparingtherepairofveneeredzirconiacrownswithceramicorcompositeresinaninvitrostudy
AT sunarthurf comparingtherepairofveneeredzirconiacrownswithceramicorcompositeresinaninvitrostudy
AT nathansondan comparingtherepairofveneeredzirconiacrownswithceramicorcompositeresinaninvitrostudy