Cargando…
Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide
BACKGROUND: With the development of three-dimensional printing (3DP) technology, the patient-specific instrumentation (PSI) has been widely applied in total knee arthroplasty (TKA). The purpose of this study was to compare the gait parameters of patients with 3DP personalized guide-assisted and stan...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7345611/ https://www.ncbi.nlm.nih.gov/pubmed/32685514 http://dx.doi.org/10.1155/2020/6485178 |
_version_ | 1783556223957729280 |
---|---|
author | Sun, Maolin Zhang, Ying Peng, Yang Fu, Dejie Fan, Huaquan He, Rui |
author_facet | Sun, Maolin Zhang, Ying Peng, Yang Fu, Dejie Fan, Huaquan He, Rui |
author_sort | Sun, Maolin |
collection | PubMed |
description | BACKGROUND: With the development of three-dimensional printing (3DP) technology, the patient-specific instrumentation (PSI) has been widely applied in total knee arthroplasty (TKA). The purpose of this study was to compare the gait parameters of patients with 3DP personalized guide-assisted and standard TKA. METHODS: Retrospective analysis of the advanced knee OA cases in our hospital between June 2017 and June 2018 was conducted. 30 cases received 3DP personalized guide-assisted TKA (group A), and 60 patients who underwent standard TKA during the same period were in group B and group C according to the computed tomography (CT) measurement results, each with 30 cases. Hip–knee–ankle angle (HKA), patella transverse axis-femoral transepicondylar axis angle (PFA), and gait parameters were statistically analyzed. The function was assessed by Hospital for Specific Surgery (HSS) and Knee Society Score (KSS). RESULTS: The mean follow-up period was 12.3 months in the three groups. The knee max flexion angle at the swing phase of group A was larger than group B and group C (P < 0.05), there was no statistically significant difference in other gait parameters. The mean PFA of group A was smaller than that of group B and group C (P < 0.05). While, the HKA, HSS, and KSS scores of three groups showed no significant difference. CONCLUSION: 3DP personalized guide technology could improve the gait parameters after surgery, specifically reflected in the knee max flexion angle at the swing phase. It could also assist in the reconstruction of more accurate patellar tracking and rotational alignment in TKA, avoiding the occurrence of insufficient or excessive extorsion. |
format | Online Article Text |
id | pubmed-7345611 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-73456112020-07-17 Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide Sun, Maolin Zhang, Ying Peng, Yang Fu, Dejie Fan, Huaquan He, Rui Biomed Res Int Clinical Study BACKGROUND: With the development of three-dimensional printing (3DP) technology, the patient-specific instrumentation (PSI) has been widely applied in total knee arthroplasty (TKA). The purpose of this study was to compare the gait parameters of patients with 3DP personalized guide-assisted and standard TKA. METHODS: Retrospective analysis of the advanced knee OA cases in our hospital between June 2017 and June 2018 was conducted. 30 cases received 3DP personalized guide-assisted TKA (group A), and 60 patients who underwent standard TKA during the same period were in group B and group C according to the computed tomography (CT) measurement results, each with 30 cases. Hip–knee–ankle angle (HKA), patella transverse axis-femoral transepicondylar axis angle (PFA), and gait parameters were statistically analyzed. The function was assessed by Hospital for Specific Surgery (HSS) and Knee Society Score (KSS). RESULTS: The mean follow-up period was 12.3 months in the three groups. The knee max flexion angle at the swing phase of group A was larger than group B and group C (P < 0.05), there was no statistically significant difference in other gait parameters. The mean PFA of group A was smaller than that of group B and group C (P < 0.05). While, the HKA, HSS, and KSS scores of three groups showed no significant difference. CONCLUSION: 3DP personalized guide technology could improve the gait parameters after surgery, specifically reflected in the knee max flexion angle at the swing phase. It could also assist in the reconstruction of more accurate patellar tracking and rotational alignment in TKA, avoiding the occurrence of insufficient or excessive extorsion. Hindawi 2020-06-30 /pmc/articles/PMC7345611/ /pubmed/32685514 http://dx.doi.org/10.1155/2020/6485178 Text en Copyright © 2020 Maolin Sun et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Sun, Maolin Zhang, Ying Peng, Yang Fu, Dejie Fan, Huaquan He, Rui Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide |
title | Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide |
title_full | Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide |
title_fullStr | Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide |
title_full_unstemmed | Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide |
title_short | Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide |
title_sort | gait analysis after total knee arthroplasty assisted by 3d-printed personalized guide |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7345611/ https://www.ncbi.nlm.nih.gov/pubmed/32685514 http://dx.doi.org/10.1155/2020/6485178 |
work_keys_str_mv | AT sunmaolin gaitanalysisaftertotalkneearthroplastyassistedby3dprintedpersonalizedguide AT zhangying gaitanalysisaftertotalkneearthroplastyassistedby3dprintedpersonalizedguide AT pengyang gaitanalysisaftertotalkneearthroplastyassistedby3dprintedpersonalizedguide AT fudejie gaitanalysisaftertotalkneearthroplastyassistedby3dprintedpersonalizedguide AT fanhuaquan gaitanalysisaftertotalkneearthroplastyassistedby3dprintedpersonalizedguide AT herui gaitanalysisaftertotalkneearthroplastyassistedby3dprintedpersonalizedguide |