Cargando…

Totally Implanted Port May Be an Alternative to Centrally Inserted Central Catheter for Measurement of Central Venous Pressure

BACKGROUND: A conventional centrally inserted central catheter (CICC) is frequently used to measure central venous pressure (CVP) to monitor the cardiocirculatory status of patients. The tip of the totally implanted port (TIP) is inserted at the same location in the superior vena cava as that of a C...

Descripción completa

Detalles Bibliográficos
Autores principales: Kuo, Wei-Ke, Huang, Chih-Yu, Yu, Chung-Chieh, Hua, Chung-Ching
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7346251/
https://www.ncbi.nlm.nih.gov/pubmed/32676177
http://dx.doi.org/10.1155/2020/9180856
_version_ 1783556369020878848
author Kuo, Wei-Ke
Huang, Chih-Yu
Yu, Chung-Chieh
Hua, Chung-Ching
author_facet Kuo, Wei-Ke
Huang, Chih-Yu
Yu, Chung-Chieh
Hua, Chung-Ching
author_sort Kuo, Wei-Ke
collection PubMed
description BACKGROUND: A conventional centrally inserted central catheter (CICC) is frequently used to measure central venous pressure (CVP) to monitor the cardiocirculatory status of patients. The tip of the totally implanted port (TIP) is inserted at the same location in the superior vena cava as that of a CICC, and the TIP has been implanted in many patients with cancer. Measurements of CVP using CICC (CICCP) and TIP (TIPP) may be closely related. Material and Methods. Ten patients with TIPs in an intensive care unit were prospectively studied, and 121 records of 4536 paired CICCP and TIPP measurements were collected. A bench test in a static or dynamic setting was performed, and 598 paired measurements taken using CICC and TIP were recorded. RESULTS: The measurement of TIPP was highly correlated with that of CICCP in patients with cancer, especially those in a calm state. Patients with a calm state and ≥3 consecutive identical TIPP were recorded (≥30 seconds), and 90% of the mean difference between CICCP and TIPP was ≤2 mmHg. The pressure measurements recorded using CICC and TIP were identical in both the static and dynamic bench tests. CONCLUSIONS: TIP may be an alternative to CICC for measuring CVP.
format Online
Article
Text
id pubmed-7346251
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-73462512020-07-15 Totally Implanted Port May Be an Alternative to Centrally Inserted Central Catheter for Measurement of Central Venous Pressure Kuo, Wei-Ke Huang, Chih-Yu Yu, Chung-Chieh Hua, Chung-Ching J Healthc Eng Research Article BACKGROUND: A conventional centrally inserted central catheter (CICC) is frequently used to measure central venous pressure (CVP) to monitor the cardiocirculatory status of patients. The tip of the totally implanted port (TIP) is inserted at the same location in the superior vena cava as that of a CICC, and the TIP has been implanted in many patients with cancer. Measurements of CVP using CICC (CICCP) and TIP (TIPP) may be closely related. Material and Methods. Ten patients with TIPs in an intensive care unit were prospectively studied, and 121 records of 4536 paired CICCP and TIPP measurements were collected. A bench test in a static or dynamic setting was performed, and 598 paired measurements taken using CICC and TIP were recorded. RESULTS: The measurement of TIPP was highly correlated with that of CICCP in patients with cancer, especially those in a calm state. Patients with a calm state and ≥3 consecutive identical TIPP were recorded (≥30 seconds), and 90% of the mean difference between CICCP and TIPP was ≤2 mmHg. The pressure measurements recorded using CICC and TIP were identical in both the static and dynamic bench tests. CONCLUSIONS: TIP may be an alternative to CICC for measuring CVP. Hindawi 2020-06-30 /pmc/articles/PMC7346251/ /pubmed/32676177 http://dx.doi.org/10.1155/2020/9180856 Text en Copyright © 2020 Wei-Ke Kuo et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kuo, Wei-Ke
Huang, Chih-Yu
Yu, Chung-Chieh
Hua, Chung-Ching
Totally Implanted Port May Be an Alternative to Centrally Inserted Central Catheter for Measurement of Central Venous Pressure
title Totally Implanted Port May Be an Alternative to Centrally Inserted Central Catheter for Measurement of Central Venous Pressure
title_full Totally Implanted Port May Be an Alternative to Centrally Inserted Central Catheter for Measurement of Central Venous Pressure
title_fullStr Totally Implanted Port May Be an Alternative to Centrally Inserted Central Catheter for Measurement of Central Venous Pressure
title_full_unstemmed Totally Implanted Port May Be an Alternative to Centrally Inserted Central Catheter for Measurement of Central Venous Pressure
title_short Totally Implanted Port May Be an Alternative to Centrally Inserted Central Catheter for Measurement of Central Venous Pressure
title_sort totally implanted port may be an alternative to centrally inserted central catheter for measurement of central venous pressure
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7346251/
https://www.ncbi.nlm.nih.gov/pubmed/32676177
http://dx.doi.org/10.1155/2020/9180856
work_keys_str_mv AT kuoweike totallyimplantedportmaybeanalternativetocentrallyinsertedcentralcatheterformeasurementofcentralvenouspressure
AT huangchihyu totallyimplantedportmaybeanalternativetocentrallyinsertedcentralcatheterformeasurementofcentralvenouspressure
AT yuchungchieh totallyimplantedportmaybeanalternativetocentrallyinsertedcentralcatheterformeasurementofcentralvenouspressure
AT huachungching totallyimplantedportmaybeanalternativetocentrallyinsertedcentralcatheterformeasurementofcentralvenouspressure