Cargando…

Calorimetric Observation of Single [Formula: see text] Excimers in a 100-mK He Bath

We report the first calorimetric detection of individual [Formula: see text] excimers within a bath of superfluid [Formula: see text] . The detector used in this work is a single superconducting titanium transition edge sensor (TES) with an energy resolution of [Formula: see text] , immersed directl...

Descripción completa

Detalles Bibliográficos
Autores principales: Carter, F. W., Hertel, S. A., Rooks, M. J., McClintock, P. V. E., McKinsey, D. N., Prober, D. E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7346980/
https://www.ncbi.nlm.nih.gov/pubmed/32669743
http://dx.doi.org/10.1007/s10909-016-1666-x
_version_ 1783556505160646656
author Carter, F. W.
Hertel, S. A.
Rooks, M. J.
McClintock, P. V. E.
McKinsey, D. N.
Prober, D. E.
author_facet Carter, F. W.
Hertel, S. A.
Rooks, M. J.
McClintock, P. V. E.
McKinsey, D. N.
Prober, D. E.
author_sort Carter, F. W.
collection PubMed
description We report the first calorimetric detection of individual [Formula: see text] excimers within a bath of superfluid [Formula: see text] . The detector used in this work is a single superconducting titanium transition edge sensor (TES) with an energy resolution of [Formula: see text] , immersed directly in the helium bath. [Formula: see text] excimers are produced in the surrounding bath using an external gamma-ray source. These excimers exist either as short-lived singlet or long-lived triplet states. We demonstrate detection (and discrimination) of both states: In the singlet case the calorimeter records the absorption of a prompt [Formula: see text] photon, and in the triplet case the calorimeter records a direct interaction of the molecule with the TES surface, which deposits a distinct fraction of the [Formula: see text] , released upon decay, into the surface. We also briefly discuss the detector fabrication and characterization.
format Online
Article
Text
id pubmed-7346980
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-73469802020-07-13 Calorimetric Observation of Single [Formula: see text] Excimers in a 100-mK He Bath Carter, F. W. Hertel, S. A. Rooks, M. J. McClintock, P. V. E. McKinsey, D. N. Prober, D. E. J Low Temp Phys Article We report the first calorimetric detection of individual [Formula: see text] excimers within a bath of superfluid [Formula: see text] . The detector used in this work is a single superconducting titanium transition edge sensor (TES) with an energy resolution of [Formula: see text] , immersed directly in the helium bath. [Formula: see text] excimers are produced in the surrounding bath using an external gamma-ray source. These excimers exist either as short-lived singlet or long-lived triplet states. We demonstrate detection (and discrimination) of both states: In the singlet case the calorimeter records the absorption of a prompt [Formula: see text] photon, and in the triplet case the calorimeter records a direct interaction of the molecule with the TES surface, which deposits a distinct fraction of the [Formula: see text] , released upon decay, into the surface. We also briefly discuss the detector fabrication and characterization. Springer US 2016-10-11 2017 /pmc/articles/PMC7346980/ /pubmed/32669743 http://dx.doi.org/10.1007/s10909-016-1666-x Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Carter, F. W.
Hertel, S. A.
Rooks, M. J.
McClintock, P. V. E.
McKinsey, D. N.
Prober, D. E.
Calorimetric Observation of Single [Formula: see text] Excimers in a 100-mK He Bath
title Calorimetric Observation of Single [Formula: see text] Excimers in a 100-mK He Bath
title_full Calorimetric Observation of Single [Formula: see text] Excimers in a 100-mK He Bath
title_fullStr Calorimetric Observation of Single [Formula: see text] Excimers in a 100-mK He Bath
title_full_unstemmed Calorimetric Observation of Single [Formula: see text] Excimers in a 100-mK He Bath
title_short Calorimetric Observation of Single [Formula: see text] Excimers in a 100-mK He Bath
title_sort calorimetric observation of single [formula: see text] excimers in a 100-mk he bath
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7346980/
https://www.ncbi.nlm.nih.gov/pubmed/32669743
http://dx.doi.org/10.1007/s10909-016-1666-x
work_keys_str_mv AT carterfw calorimetricobservationofsingleformulaseetextexcimersina100mkhebath
AT hertelsa calorimetricobservationofsingleformulaseetextexcimersina100mkhebath
AT rooksmj calorimetricobservationofsingleformulaseetextexcimersina100mkhebath
AT mcclintockpve calorimetricobservationofsingleformulaseetextexcimersina100mkhebath
AT mckinseydn calorimetricobservationofsingleformulaseetextexcimersina100mkhebath
AT proberde calorimetricobservationofsingleformulaseetextexcimersina100mkhebath