Cargando…
Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery?
Robotic assistance with integrated navigation is an area of high interest for improving the accuracy of minimally invasive pedicle screw placement. This study analyzes the accuracy of pedicle screw placement between an attending spine surgeon and a resident by comparing the left and right sides of t...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer London
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7347677/ https://www.ncbi.nlm.nih.gov/pubmed/31542860 http://dx.doi.org/10.1007/s11701-019-01019-9 |
_version_ | 1783556639341674496 |
---|---|
author | Vardiman, Arnold B. Wallace, David J. Booher, Grant A. Crawford, Neil R. Riggleman, Jessica R. Greeley, Samantha L. Ledonio, Charles G. |
author_facet | Vardiman, Arnold B. Wallace, David J. Booher, Grant A. Crawford, Neil R. Riggleman, Jessica R. Greeley, Samantha L. Ledonio, Charles G. |
author_sort | Vardiman, Arnold B. |
collection | PubMed |
description | Robotic assistance with integrated navigation is an area of high interest for improving the accuracy of minimally invasive pedicle screw placement. This study analyzes the accuracy of pedicle screw placement between an attending spine surgeon and a resident by comparing the left and right sides of the first 101 consecutive cases using navigated robotic assistance in a private practice clinical setting. A retrospective, Institutional Review Board-exempt review of the first 106 navigated robot-assisted spine surgery cases was performed. One attending spine surgeon and one resident performed pedicle screw placement consistently on either the left or right side (researchers were blinded). A CT-based Gertzbein and Robbins system (GRS) was used to classify pedicle screw accuracy, with grade A or B considered accurate. There were 630 consecutive lumbosacral pedicle screws placed. Thirty screws (5 patients) were placed without the robot due to surgeon discretion. Of the 600 pedicle screws inserted by navigated robotic guidance (101 patients), only 1.5% (9/600) were repositioned intraoperatively. Based on the GRS CT-based grading of pedicle breach, 98.67% (296/300) of left-side screws were graded A or B, 1.3% (4/300) were graded C, and 0% (0/300) were graded D. For the right-side screws, 97.67% (293/300) were graded A or B, 1.67% (5/300) were graded C, and 0.66% (2/300) were graded D. This study demonstrated a high level of accuracy (based on GRS) with no significant differences between the left- and right-side pedicle screw placements (98.67% vs. 97.67%, respectively) in the clinical use of navigated, robot-assisted surgery. |
format | Online Article Text |
id | pubmed-7347677 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer London |
record_format | MEDLINE/PubMed |
spelling | pubmed-73476772020-07-13 Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery? Vardiman, Arnold B. Wallace, David J. Booher, Grant A. Crawford, Neil R. Riggleman, Jessica R. Greeley, Samantha L. Ledonio, Charles G. J Robot Surg Original Article Robotic assistance with integrated navigation is an area of high interest for improving the accuracy of minimally invasive pedicle screw placement. This study analyzes the accuracy of pedicle screw placement between an attending spine surgeon and a resident by comparing the left and right sides of the first 101 consecutive cases using navigated robotic assistance in a private practice clinical setting. A retrospective, Institutional Review Board-exempt review of the first 106 navigated robot-assisted spine surgery cases was performed. One attending spine surgeon and one resident performed pedicle screw placement consistently on either the left or right side (researchers were blinded). A CT-based Gertzbein and Robbins system (GRS) was used to classify pedicle screw accuracy, with grade A or B considered accurate. There were 630 consecutive lumbosacral pedicle screws placed. Thirty screws (5 patients) were placed without the robot due to surgeon discretion. Of the 600 pedicle screws inserted by navigated robotic guidance (101 patients), only 1.5% (9/600) were repositioned intraoperatively. Based on the GRS CT-based grading of pedicle breach, 98.67% (296/300) of left-side screws were graded A or B, 1.3% (4/300) were graded C, and 0% (0/300) were graded D. For the right-side screws, 97.67% (293/300) were graded A or B, 1.67% (5/300) were graded C, and 0.66% (2/300) were graded D. This study demonstrated a high level of accuracy (based on GRS) with no significant differences between the left- and right-side pedicle screw placements (98.67% vs. 97.67%, respectively) in the clinical use of navigated, robot-assisted surgery. Springer London 2019-09-21 2020 /pmc/articles/PMC7347677/ /pubmed/31542860 http://dx.doi.org/10.1007/s11701-019-01019-9 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Vardiman, Arnold B. Wallace, David J. Booher, Grant A. Crawford, Neil R. Riggleman, Jessica R. Greeley, Samantha L. Ledonio, Charles G. Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery? |
title | Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery? |
title_full | Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery? |
title_fullStr | Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery? |
title_full_unstemmed | Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery? |
title_short | Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery? |
title_sort | does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery? |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7347677/ https://www.ncbi.nlm.nih.gov/pubmed/31542860 http://dx.doi.org/10.1007/s11701-019-01019-9 |
work_keys_str_mv | AT vardimanarnoldb doestheaccuracyofpediclescrewplacementdifferbetweentheattendingsurgeonandresidentinnavigatedroboticassistedminimallyinvasivespinesurgery AT wallacedavidj doestheaccuracyofpediclescrewplacementdifferbetweentheattendingsurgeonandresidentinnavigatedroboticassistedminimallyinvasivespinesurgery AT boohergranta doestheaccuracyofpediclescrewplacementdifferbetweentheattendingsurgeonandresidentinnavigatedroboticassistedminimallyinvasivespinesurgery AT crawfordneilr doestheaccuracyofpediclescrewplacementdifferbetweentheattendingsurgeonandresidentinnavigatedroboticassistedminimallyinvasivespinesurgery AT rigglemanjessicar doestheaccuracyofpediclescrewplacementdifferbetweentheattendingsurgeonandresidentinnavigatedroboticassistedminimallyinvasivespinesurgery AT greeleysamanthal doestheaccuracyofpediclescrewplacementdifferbetweentheattendingsurgeonandresidentinnavigatedroboticassistedminimallyinvasivespinesurgery AT ledoniocharlesg doestheaccuracyofpediclescrewplacementdifferbetweentheattendingsurgeonandresidentinnavigatedroboticassistedminimallyinvasivespinesurgery |