Cargando…

Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices

Nowadays, electrochemical biosensors are reliable analytical tools to determine a broad range of molecular analytes because of their simplicity, affordable cost, and compatibility with multiplexed and point-of-care strategies. There is an increasing demand to improve their sensitivity and selectivit...

Descripción completa

Detalles Bibliográficos
Autores principales: Campuzano, Susana, Pedrero, María, Gamella, Maria, Serafín, Verónica, Yáñez-Sedeño, Paloma, Pingarrón, José Manuel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7348748/
https://www.ncbi.nlm.nih.gov/pubmed/32560028
http://dx.doi.org/10.3390/s20123376
_version_ 1783556901724749824
author Campuzano, Susana
Pedrero, María
Gamella, Maria
Serafín, Verónica
Yáñez-Sedeño, Paloma
Pingarrón, José Manuel
author_facet Campuzano, Susana
Pedrero, María
Gamella, Maria
Serafín, Verónica
Yáñez-Sedeño, Paloma
Pingarrón, José Manuel
author_sort Campuzano, Susana
collection PubMed
description Nowadays, electrochemical biosensors are reliable analytical tools to determine a broad range of molecular analytes because of their simplicity, affordable cost, and compatibility with multiplexed and point-of-care strategies. There is an increasing demand to improve their sensitivity and selectivity, but also to provide electrochemical biosensors with important attributes such as near real-time and continuous monitoring in complex or denaturing media, or in vivo with minimal intervention to make them even more attractive and suitable for getting into the real world. Modification of biosensors surfaces with antibiofouling reagents, smart coupling with nanomaterials, and the advances experienced by folded-based biosensors have endowed bioelectroanalytical platforms with one or more of such attributes. With this background in mind, this review aims to give an updated and general overview of these technologies as well as to discuss the remarkable achievements arising from the development of electrochemical biosensors free of reagents, washing, or calibration steps, and/or with antifouling properties and the ability to perform continuous, real-time, and even in vivo operation in nearly autonomous way. The challenges to be faced and the next features that these devices may offer to continue impacting in fields closely related with essential aspects of people’s safety and health are also commented upon.
format Online
Article
Text
id pubmed-7348748
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73487482020-07-20 Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices Campuzano, Susana Pedrero, María Gamella, Maria Serafín, Verónica Yáñez-Sedeño, Paloma Pingarrón, José Manuel Sensors (Basel) Review Nowadays, electrochemical biosensors are reliable analytical tools to determine a broad range of molecular analytes because of their simplicity, affordable cost, and compatibility with multiplexed and point-of-care strategies. There is an increasing demand to improve their sensitivity and selectivity, but also to provide electrochemical biosensors with important attributes such as near real-time and continuous monitoring in complex or denaturing media, or in vivo with minimal intervention to make them even more attractive and suitable for getting into the real world. Modification of biosensors surfaces with antibiofouling reagents, smart coupling with nanomaterials, and the advances experienced by folded-based biosensors have endowed bioelectroanalytical platforms with one or more of such attributes. With this background in mind, this review aims to give an updated and general overview of these technologies as well as to discuss the remarkable achievements arising from the development of electrochemical biosensors free of reagents, washing, or calibration steps, and/or with antifouling properties and the ability to perform continuous, real-time, and even in vivo operation in nearly autonomous way. The challenges to be faced and the next features that these devices may offer to continue impacting in fields closely related with essential aspects of people’s safety and health are also commented upon. MDPI 2020-06-16 /pmc/articles/PMC7348748/ /pubmed/32560028 http://dx.doi.org/10.3390/s20123376 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Campuzano, Susana
Pedrero, María
Gamella, Maria
Serafín, Verónica
Yáñez-Sedeño, Paloma
Pingarrón, José Manuel
Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices
title Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices
title_full Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices
title_fullStr Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices
title_full_unstemmed Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices
title_short Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices
title_sort beyond sensitive and selective electrochemical biosensors: towards continuous, real-time, antibiofouling and calibration-free devices
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7348748/
https://www.ncbi.nlm.nih.gov/pubmed/32560028
http://dx.doi.org/10.3390/s20123376
work_keys_str_mv AT campuzanosusana beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices
AT pedreromaria beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices
AT gamellamaria beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices
AT serafinveronica beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices
AT yanezsedenopaloma beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices
AT pingarronjosemanuel beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices