Cargando…
Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices
Nowadays, electrochemical biosensors are reliable analytical tools to determine a broad range of molecular analytes because of their simplicity, affordable cost, and compatibility with multiplexed and point-of-care strategies. There is an increasing demand to improve their sensitivity and selectivit...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7348748/ https://www.ncbi.nlm.nih.gov/pubmed/32560028 http://dx.doi.org/10.3390/s20123376 |
_version_ | 1783556901724749824 |
---|---|
author | Campuzano, Susana Pedrero, María Gamella, Maria Serafín, Verónica Yáñez-Sedeño, Paloma Pingarrón, José Manuel |
author_facet | Campuzano, Susana Pedrero, María Gamella, Maria Serafín, Verónica Yáñez-Sedeño, Paloma Pingarrón, José Manuel |
author_sort | Campuzano, Susana |
collection | PubMed |
description | Nowadays, electrochemical biosensors are reliable analytical tools to determine a broad range of molecular analytes because of their simplicity, affordable cost, and compatibility with multiplexed and point-of-care strategies. There is an increasing demand to improve their sensitivity and selectivity, but also to provide electrochemical biosensors with important attributes such as near real-time and continuous monitoring in complex or denaturing media, or in vivo with minimal intervention to make them even more attractive and suitable for getting into the real world. Modification of biosensors surfaces with antibiofouling reagents, smart coupling with nanomaterials, and the advances experienced by folded-based biosensors have endowed bioelectroanalytical platforms with one or more of such attributes. With this background in mind, this review aims to give an updated and general overview of these technologies as well as to discuss the remarkable achievements arising from the development of electrochemical biosensors free of reagents, washing, or calibration steps, and/or with antifouling properties and the ability to perform continuous, real-time, and even in vivo operation in nearly autonomous way. The challenges to be faced and the next features that these devices may offer to continue impacting in fields closely related with essential aspects of people’s safety and health are also commented upon. |
format | Online Article Text |
id | pubmed-7348748 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-73487482020-07-20 Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices Campuzano, Susana Pedrero, María Gamella, Maria Serafín, Verónica Yáñez-Sedeño, Paloma Pingarrón, José Manuel Sensors (Basel) Review Nowadays, electrochemical biosensors are reliable analytical tools to determine a broad range of molecular analytes because of their simplicity, affordable cost, and compatibility with multiplexed and point-of-care strategies. There is an increasing demand to improve their sensitivity and selectivity, but also to provide electrochemical biosensors with important attributes such as near real-time and continuous monitoring in complex or denaturing media, or in vivo with minimal intervention to make them even more attractive and suitable for getting into the real world. Modification of biosensors surfaces with antibiofouling reagents, smart coupling with nanomaterials, and the advances experienced by folded-based biosensors have endowed bioelectroanalytical platforms with one or more of such attributes. With this background in mind, this review aims to give an updated and general overview of these technologies as well as to discuss the remarkable achievements arising from the development of electrochemical biosensors free of reagents, washing, or calibration steps, and/or with antifouling properties and the ability to perform continuous, real-time, and even in vivo operation in nearly autonomous way. The challenges to be faced and the next features that these devices may offer to continue impacting in fields closely related with essential aspects of people’s safety and health are also commented upon. MDPI 2020-06-16 /pmc/articles/PMC7348748/ /pubmed/32560028 http://dx.doi.org/10.3390/s20123376 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Campuzano, Susana Pedrero, María Gamella, Maria Serafín, Verónica Yáñez-Sedeño, Paloma Pingarrón, José Manuel Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices |
title | Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices |
title_full | Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices |
title_fullStr | Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices |
title_full_unstemmed | Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices |
title_short | Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices |
title_sort | beyond sensitive and selective electrochemical biosensors: towards continuous, real-time, antibiofouling and calibration-free devices |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7348748/ https://www.ncbi.nlm.nih.gov/pubmed/32560028 http://dx.doi.org/10.3390/s20123376 |
work_keys_str_mv | AT campuzanosusana beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices AT pedreromaria beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices AT gamellamaria beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices AT serafinveronica beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices AT yanezsedenopaloma beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices AT pingarronjosemanuel beyondsensitiveandselectiveelectrochemicalbiosensorstowardscontinuousrealtimeantibiofoulingandcalibrationfreedevices |