Cargando…

An Ultrasonic Rheometer to Measure Gas Absorption in Ionic Liquids: Design, Calibration and Testing

The first goal of this study is to identify the ideal piezoelectric material for the manufacturing of rheological reflectance ultrasonic sensors. The second goal is to integrate the ultrasonic rheometer within a gas absorption reactor and to measure viscosity changes in an ionic liquid (IL) caused b...

Descripción completa

Detalles Bibliográficos
Autores principales: Schirru, Michele, Adler, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7349107/
https://www.ncbi.nlm.nih.gov/pubmed/32585862
http://dx.doi.org/10.3390/s20123544
_version_ 1783556986361610240
author Schirru, Michele
Adler, Michael
author_facet Schirru, Michele
Adler, Michael
author_sort Schirru, Michele
collection PubMed
description The first goal of this study is to identify the ideal piezoelectric material for the manufacturing of rheological reflectance ultrasonic sensors. The second goal is to integrate the ultrasonic rheometer within a gas absorption reactor and to measure viscosity changes in an ionic liquid (IL) caused by gas absorption. To achieve the objectives, bismuth titanate, lead titanate, lead metaniobate and lead zirconate titanate materials in layer, tungsten bronze and perovskite structures were assembled on aluminum delay lines and tested under thermal cycling between room temperature and 150 °C. The results showed that lead metaniobate in tungsten bronze structure is the most suitable material for long time duration thermal cycling. Therefore, the ultrasonic rheometer was assembled using this material and installed in a pressurized reactor to test a reference IL at the operating conditions of 50 °C and at a pressure of 80 bar. The reference IL was saturated with nitrogen as well as hydrogen gas. Viscosity signals remained constant under the hydrogen atmosphere, while in nitrogen atmosphere the absorption of the gas lead to a rise in the value of viscosity.
format Online
Article
Text
id pubmed-7349107
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73491072020-07-22 An Ultrasonic Rheometer to Measure Gas Absorption in Ionic Liquids: Design, Calibration and Testing Schirru, Michele Adler, Michael Sensors (Basel) Article The first goal of this study is to identify the ideal piezoelectric material for the manufacturing of rheological reflectance ultrasonic sensors. The second goal is to integrate the ultrasonic rheometer within a gas absorption reactor and to measure viscosity changes in an ionic liquid (IL) caused by gas absorption. To achieve the objectives, bismuth titanate, lead titanate, lead metaniobate and lead zirconate titanate materials in layer, tungsten bronze and perovskite structures were assembled on aluminum delay lines and tested under thermal cycling between room temperature and 150 °C. The results showed that lead metaniobate in tungsten bronze structure is the most suitable material for long time duration thermal cycling. Therefore, the ultrasonic rheometer was assembled using this material and installed in a pressurized reactor to test a reference IL at the operating conditions of 50 °C and at a pressure of 80 bar. The reference IL was saturated with nitrogen as well as hydrogen gas. Viscosity signals remained constant under the hydrogen atmosphere, while in nitrogen atmosphere the absorption of the gas lead to a rise in the value of viscosity. MDPI 2020-06-23 /pmc/articles/PMC7349107/ /pubmed/32585862 http://dx.doi.org/10.3390/s20123544 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Schirru, Michele
Adler, Michael
An Ultrasonic Rheometer to Measure Gas Absorption in Ionic Liquids: Design, Calibration and Testing
title An Ultrasonic Rheometer to Measure Gas Absorption in Ionic Liquids: Design, Calibration and Testing
title_full An Ultrasonic Rheometer to Measure Gas Absorption in Ionic Liquids: Design, Calibration and Testing
title_fullStr An Ultrasonic Rheometer to Measure Gas Absorption in Ionic Liquids: Design, Calibration and Testing
title_full_unstemmed An Ultrasonic Rheometer to Measure Gas Absorption in Ionic Liquids: Design, Calibration and Testing
title_short An Ultrasonic Rheometer to Measure Gas Absorption in Ionic Liquids: Design, Calibration and Testing
title_sort ultrasonic rheometer to measure gas absorption in ionic liquids: design, calibration and testing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7349107/
https://www.ncbi.nlm.nih.gov/pubmed/32585862
http://dx.doi.org/10.3390/s20123544
work_keys_str_mv AT schirrumichele anultrasonicrheometertomeasuregasabsorptioninionicliquidsdesigncalibrationandtesting
AT adlermichael anultrasonicrheometertomeasuregasabsorptioninionicliquidsdesigncalibrationandtesting
AT schirrumichele ultrasonicrheometertomeasuregasabsorptioninionicliquidsdesigncalibrationandtesting
AT adlermichael ultrasonicrheometertomeasuregasabsorptioninionicliquidsdesigncalibrationandtesting