Cargando…

Rapid Direct Nucleic Acid Amplification Test without RNA Extraction for SARS-CoV-2 Using a Portable PCR Thermocycler

There is an ongoing worldwide coronavirus disease 2019 (Covid-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). At present, confirmatory diagnosis is by reverse transcription polymerase chain reaction (RT-PCR), typically taking several hours and requiring a molecul...

Descripción completa

Detalles Bibliográficos
Autores principales: Wee, Soon Keong, Sivalingam, Suppiah Paramalingam, Yap, Eric Peng Huat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7349311/
https://www.ncbi.nlm.nih.gov/pubmed/32570810
http://dx.doi.org/10.3390/genes11060664
_version_ 1783557034188210176
author Wee, Soon Keong
Sivalingam, Suppiah Paramalingam
Yap, Eric Peng Huat
author_facet Wee, Soon Keong
Sivalingam, Suppiah Paramalingam
Yap, Eric Peng Huat
author_sort Wee, Soon Keong
collection PubMed
description There is an ongoing worldwide coronavirus disease 2019 (Covid-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). At present, confirmatory diagnosis is by reverse transcription polymerase chain reaction (RT-PCR), typically taking several hours and requiring a molecular laboratory to perform. There is an urgent need for rapid, simplified, and cost-effective detection methods. We have developed and analytically validated a protocol for direct rapid extraction-free PCR (DIRECT-PCR) detection of SARS-CoV-2 without the need for nucleic acid purification. As few as six RNA copies per reaction of viral nucleocapsid (N) gene from respiratory samples such as sputum and nasal exudate can be detected directly using our one-step inhibitor-resistant assay. The performance of this assay was validated on a commercially available portable PCR thermocycler. Viral lysis, reverse transcription, amplification, and detection are achieved in a single-tube homogeneous reaction within 36 min. This minimizes hands-on time, reduces turnaround-time for sample-to-result, and obviates the need for RNA purification reagents. It could enable wider use of Covid-19 testing for diagnosis, screening, and research in countries and regions where laboratory capabilities are limiting.
format Online
Article
Text
id pubmed-7349311
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73493112020-07-22 Rapid Direct Nucleic Acid Amplification Test without RNA Extraction for SARS-CoV-2 Using a Portable PCR Thermocycler Wee, Soon Keong Sivalingam, Suppiah Paramalingam Yap, Eric Peng Huat Genes (Basel) Article There is an ongoing worldwide coronavirus disease 2019 (Covid-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). At present, confirmatory diagnosis is by reverse transcription polymerase chain reaction (RT-PCR), typically taking several hours and requiring a molecular laboratory to perform. There is an urgent need for rapid, simplified, and cost-effective detection methods. We have developed and analytically validated a protocol for direct rapid extraction-free PCR (DIRECT-PCR) detection of SARS-CoV-2 without the need for nucleic acid purification. As few as six RNA copies per reaction of viral nucleocapsid (N) gene from respiratory samples such as sputum and nasal exudate can be detected directly using our one-step inhibitor-resistant assay. The performance of this assay was validated on a commercially available portable PCR thermocycler. Viral lysis, reverse transcription, amplification, and detection are achieved in a single-tube homogeneous reaction within 36 min. This minimizes hands-on time, reduces turnaround-time for sample-to-result, and obviates the need for RNA purification reagents. It could enable wider use of Covid-19 testing for diagnosis, screening, and research in countries and regions where laboratory capabilities are limiting. MDPI 2020-06-18 /pmc/articles/PMC7349311/ /pubmed/32570810 http://dx.doi.org/10.3390/genes11060664 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wee, Soon Keong
Sivalingam, Suppiah Paramalingam
Yap, Eric Peng Huat
Rapid Direct Nucleic Acid Amplification Test without RNA Extraction for SARS-CoV-2 Using a Portable PCR Thermocycler
title Rapid Direct Nucleic Acid Amplification Test without RNA Extraction for SARS-CoV-2 Using a Portable PCR Thermocycler
title_full Rapid Direct Nucleic Acid Amplification Test without RNA Extraction for SARS-CoV-2 Using a Portable PCR Thermocycler
title_fullStr Rapid Direct Nucleic Acid Amplification Test without RNA Extraction for SARS-CoV-2 Using a Portable PCR Thermocycler
title_full_unstemmed Rapid Direct Nucleic Acid Amplification Test without RNA Extraction for SARS-CoV-2 Using a Portable PCR Thermocycler
title_short Rapid Direct Nucleic Acid Amplification Test without RNA Extraction for SARS-CoV-2 Using a Portable PCR Thermocycler
title_sort rapid direct nucleic acid amplification test without rna extraction for sars-cov-2 using a portable pcr thermocycler
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7349311/
https://www.ncbi.nlm.nih.gov/pubmed/32570810
http://dx.doi.org/10.3390/genes11060664
work_keys_str_mv AT weesoonkeong rapiddirectnucleicacidamplificationtestwithoutrnaextractionforsarscov2usingaportablepcrthermocycler
AT sivalingamsuppiahparamalingam rapiddirectnucleicacidamplificationtestwithoutrnaextractionforsarscov2usingaportablepcrthermocycler
AT yapericpenghuat rapiddirectnucleicacidamplificationtestwithoutrnaextractionforsarscov2usingaportablepcrthermocycler