Cargando…

Traumatic Fracture: Dislocation of Cervicothoracic Junction—Grand Round Presentation of C7-T1 Instabilities and Different Instrumentation Techniques

INTRODUCTION: Acute traumatic cervicothoracic junction spinal lesions are rare disorders and poorly documented. We report a case of a traumatic cervicothoracic fracture-dislocation. We present our experience in the operative treatment of an unstable fracture-dislocation at the cervicothoracic juncti...

Descripción completa

Detalles Bibliográficos
Autores principales: Alsofyani, Mohammad A., Ghailane, Soufiane, Alsalmi, Sultan, Jakinapally, Sreenath, Boissière, Louis, Obeid, Ibrahim, Vital, Jean-Marc
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7349622/
https://www.ncbi.nlm.nih.gov/pubmed/32665871
http://dx.doi.org/10.1155/2020/7578628
_version_ 1783557097583017984
author Alsofyani, Mohammad A.
Ghailane, Soufiane
Alsalmi, Sultan
Jakinapally, Sreenath
Boissière, Louis
Obeid, Ibrahim
Vital, Jean-Marc
author_facet Alsofyani, Mohammad A.
Ghailane, Soufiane
Alsalmi, Sultan
Jakinapally, Sreenath
Boissière, Louis
Obeid, Ibrahim
Vital, Jean-Marc
author_sort Alsofyani, Mohammad A.
collection PubMed
description INTRODUCTION: Acute traumatic cervicothoracic junction spinal lesions are rare disorders and poorly documented. We report a case of a traumatic cervicothoracic fracture-dislocation. We present our experience in the operative treatment of an unstable fracture-dislocation at the cervicothoracic junction. Materials and Method. A seventy-year-old man was transferred to our hospital. We found paresthesia in the corresponding dermatome of C7 and C8 bilaterally. Initial CT scan shows vertebral body fracture of T1 with retropulsion into the spinal canal and anteroposterior dislocation of cervicothoracic junction type C according to AOSpine subaxial injury. Traumatic disc material at C7-T1 was removed by anterior cervical discectomy and fusion of C6-T2. Fixation was done from C6 to T2 in the prone position. RESULTS: At one-year postoperative follow-up, radiographs revealed bony fusion at the level of C7-T1, and the patient had no major functional disability. CONCLUSION: We opted for the ventral-dorsal approach in our case for maximum stabilization and to prevent mechanical complications.
format Online
Article
Text
id pubmed-7349622
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-73496222020-07-13 Traumatic Fracture: Dislocation of Cervicothoracic Junction—Grand Round Presentation of C7-T1 Instabilities and Different Instrumentation Techniques Alsofyani, Mohammad A. Ghailane, Soufiane Alsalmi, Sultan Jakinapally, Sreenath Boissière, Louis Obeid, Ibrahim Vital, Jean-Marc Case Rep Orthop Case Report INTRODUCTION: Acute traumatic cervicothoracic junction spinal lesions are rare disorders and poorly documented. We report a case of a traumatic cervicothoracic fracture-dislocation. We present our experience in the operative treatment of an unstable fracture-dislocation at the cervicothoracic junction. Materials and Method. A seventy-year-old man was transferred to our hospital. We found paresthesia in the corresponding dermatome of C7 and C8 bilaterally. Initial CT scan shows vertebral body fracture of T1 with retropulsion into the spinal canal and anteroposterior dislocation of cervicothoracic junction type C according to AOSpine subaxial injury. Traumatic disc material at C7-T1 was removed by anterior cervical discectomy and fusion of C6-T2. Fixation was done from C6 to T2 in the prone position. RESULTS: At one-year postoperative follow-up, radiographs revealed bony fusion at the level of C7-T1, and the patient had no major functional disability. CONCLUSION: We opted for the ventral-dorsal approach in our case for maximum stabilization and to prevent mechanical complications. Hindawi 2020-07-01 /pmc/articles/PMC7349622/ /pubmed/32665871 http://dx.doi.org/10.1155/2020/7578628 Text en Copyright © 2020 Mohammad A. Alsofyani et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Alsofyani, Mohammad A.
Ghailane, Soufiane
Alsalmi, Sultan
Jakinapally, Sreenath
Boissière, Louis
Obeid, Ibrahim
Vital, Jean-Marc
Traumatic Fracture: Dislocation of Cervicothoracic Junction—Grand Round Presentation of C7-T1 Instabilities and Different Instrumentation Techniques
title Traumatic Fracture: Dislocation of Cervicothoracic Junction—Grand Round Presentation of C7-T1 Instabilities and Different Instrumentation Techniques
title_full Traumatic Fracture: Dislocation of Cervicothoracic Junction—Grand Round Presentation of C7-T1 Instabilities and Different Instrumentation Techniques
title_fullStr Traumatic Fracture: Dislocation of Cervicothoracic Junction—Grand Round Presentation of C7-T1 Instabilities and Different Instrumentation Techniques
title_full_unstemmed Traumatic Fracture: Dislocation of Cervicothoracic Junction—Grand Round Presentation of C7-T1 Instabilities and Different Instrumentation Techniques
title_short Traumatic Fracture: Dislocation of Cervicothoracic Junction—Grand Round Presentation of C7-T1 Instabilities and Different Instrumentation Techniques
title_sort traumatic fracture: dislocation of cervicothoracic junction—grand round presentation of c7-t1 instabilities and different instrumentation techniques
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7349622/
https://www.ncbi.nlm.nih.gov/pubmed/32665871
http://dx.doi.org/10.1155/2020/7578628
work_keys_str_mv AT alsofyanimohammada traumaticfracturedislocationofcervicothoracicjunctiongrandroundpresentationofc7t1instabilitiesanddifferentinstrumentationtechniques
AT ghailanesoufiane traumaticfracturedislocationofcervicothoracicjunctiongrandroundpresentationofc7t1instabilitiesanddifferentinstrumentationtechniques
AT alsalmisultan traumaticfracturedislocationofcervicothoracicjunctiongrandroundpresentationofc7t1instabilitiesanddifferentinstrumentationtechniques
AT jakinapallysreenath traumaticfracturedislocationofcervicothoracicjunctiongrandroundpresentationofc7t1instabilitiesanddifferentinstrumentationtechniques
AT boissierelouis traumaticfracturedislocationofcervicothoracicjunctiongrandroundpresentationofc7t1instabilitiesanddifferentinstrumentationtechniques
AT obeidibrahim traumaticfracturedislocationofcervicothoracicjunctiongrandroundpresentationofc7t1instabilitiesanddifferentinstrumentationtechniques
AT vitaljeanmarc traumaticfracturedislocationofcervicothoracicjunctiongrandroundpresentationofc7t1instabilitiesanddifferentinstrumentationtechniques