Cargando…

First-Step PPG Signal Analysis for Evaluation of Stress Induced during Scanning in the Open-Air MRI Device †

The paper describes first-step experiments with parallel measurement of cardiovascular parameters using a photoplethysmographic optical sensor and standard portable blood pressure monitors in different situations of body relaxation and stimulation. Changes in the human cardiovascular system are main...

Descripción completa

Detalles Bibliográficos
Autores principales: Přibil, Jiří, Přibilová, Anna, Frollo, Ivan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7349840/
https://www.ncbi.nlm.nih.gov/pubmed/32580364
http://dx.doi.org/10.3390/s20123532
_version_ 1783557147858042880
author Přibil, Jiří
Přibilová, Anna
Frollo, Ivan
author_facet Přibil, Jiří
Přibilová, Anna
Frollo, Ivan
author_sort Přibil, Jiří
collection PubMed
description The paper describes first-step experiments with parallel measurement of cardiovascular parameters using a photoplethysmographic optical sensor and standard portable blood pressure monitors in different situations of body relaxation and stimulation. Changes in the human cardiovascular system are mainly manifested by differences in the Oliva–Roztocil index, the instantaneous heart rate, and variations in blood pressure. In the auxiliary experiments, different physiological and psychological stimuli were applied to test whether relaxation and activation phases produce different measured parameters suitable for further statistical analysis and processing. The principal investigation is aimed at analysis of vibration and acoustic noise impact on a physiological and psychological state of a person lying inside the low-field open-air magnetic resonance imager (MRI). The obtained results will be used to analyze, quantify, and suppress a possible stress factor that has an impact on the speech signal recorded during scanning in the MRI device in the research aimed at 3D modeling of the human vocal tract.
format Online
Article
Text
id pubmed-7349840
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73498402020-07-15 First-Step PPG Signal Analysis for Evaluation of Stress Induced during Scanning in the Open-Air MRI Device † Přibil, Jiří Přibilová, Anna Frollo, Ivan Sensors (Basel) Article The paper describes first-step experiments with parallel measurement of cardiovascular parameters using a photoplethysmographic optical sensor and standard portable blood pressure monitors in different situations of body relaxation and stimulation. Changes in the human cardiovascular system are mainly manifested by differences in the Oliva–Roztocil index, the instantaneous heart rate, and variations in blood pressure. In the auxiliary experiments, different physiological and psychological stimuli were applied to test whether relaxation and activation phases produce different measured parameters suitable for further statistical analysis and processing. The principal investigation is aimed at analysis of vibration and acoustic noise impact on a physiological and psychological state of a person lying inside the low-field open-air magnetic resonance imager (MRI). The obtained results will be used to analyze, quantify, and suppress a possible stress factor that has an impact on the speech signal recorded during scanning in the MRI device in the research aimed at 3D modeling of the human vocal tract. MDPI 2020-06-22 /pmc/articles/PMC7349840/ /pubmed/32580364 http://dx.doi.org/10.3390/s20123532 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Přibil, Jiří
Přibilová, Anna
Frollo, Ivan
First-Step PPG Signal Analysis for Evaluation of Stress Induced during Scanning in the Open-Air MRI Device †
title First-Step PPG Signal Analysis for Evaluation of Stress Induced during Scanning in the Open-Air MRI Device †
title_full First-Step PPG Signal Analysis for Evaluation of Stress Induced during Scanning in the Open-Air MRI Device †
title_fullStr First-Step PPG Signal Analysis for Evaluation of Stress Induced during Scanning in the Open-Air MRI Device †
title_full_unstemmed First-Step PPG Signal Analysis for Evaluation of Stress Induced during Scanning in the Open-Air MRI Device †
title_short First-Step PPG Signal Analysis for Evaluation of Stress Induced during Scanning in the Open-Air MRI Device †
title_sort first-step ppg signal analysis for evaluation of stress induced during scanning in the open-air mri device †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7349840/
https://www.ncbi.nlm.nih.gov/pubmed/32580364
http://dx.doi.org/10.3390/s20123532
work_keys_str_mv AT pribiljiri firststepppgsignalanalysisforevaluationofstressinducedduringscanningintheopenairmridevice
AT pribilovaanna firststepppgsignalanalysisforevaluationofstressinducedduringscanningintheopenairmridevice
AT frolloivan firststepppgsignalanalysisforevaluationofstressinducedduringscanningintheopenairmridevice