A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology

PURPOSE: To compare the corneal biomechanical parameters among pseudoexfoliation syndrome (PXF), pseudoexfoliation glaucoma (PXG), and healthy controls using Corvis Scheimpflug Technology (ST). METHODS: A prospective, cross-sectional study of 141 treatment-naïve eyes that underwent Corvis ST was con...

Descripción completa

Detalles Bibliográficos
Autores principales: Pradhan, Zia S, Deshmukh, Sujit, Dixit, Shivani, Gudetti, Praveena, Devi, Sathi, Webers, Carroll A B, Rao, Harsha L
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7350500/
https://www.ncbi.nlm.nih.gov/pubmed/32317447
http://dx.doi.org/10.4103/ijo.IJO_1550_19
_version_ 1783557282608447488
author Pradhan, Zia S
Deshmukh, Sujit
Dixit, Shivani
Gudetti, Praveena
Devi, Sathi
Webers, Carroll A B
Rao, Harsha L
author_facet Pradhan, Zia S
Deshmukh, Sujit
Dixit, Shivani
Gudetti, Praveena
Devi, Sathi
Webers, Carroll A B
Rao, Harsha L
author_sort Pradhan, Zia S
collection PubMed
description PURPOSE: To compare the corneal biomechanical parameters among pseudoexfoliation syndrome (PXF), pseudoexfoliation glaucoma (PXG), and healthy controls using Corvis Scheimpflug Technology (ST). METHODS: A prospective, cross-sectional study of 141 treatment-naïve eyes that underwent Corvis ST was conducted. These included 42 eyes with PXF, 17 eyes of PXF with ocular hypertension (PXF + OHT) defined as intraocular pressure (IOP) >21 mmHg without disc/field changes, 37 eyes with PXG, and 45 healthy controls. Corneal biomechanical parameters, which included corneal velocities, length of corneal applanated surface, deformation amplitude (DA), peak distance, and radius of curvature, were compared among the groups using analysis of variance models. RESULTS: The four groups were demographically similar. The mean IOP was lower in the controls (15.6 ± 3 mmHg) and PXF group (16.0 ± 3 mmHg) compared to the other two groups (>24 mmHg). Corneal pachymetry was similar across the four groups. Mean DA was significantly lower (P < 0.0001) in the PXG group (0.91 ± 0.18 mm) and the PXF + OHT group (0.94 ± 0.13 mm) when compared to the PXF (1.10 ± 0.11 mm) and control groups (1.12 ± 0.14 mm). Corneal velocities were also found to be statistically significantly lower in PXG and PXF + OHT compared to the PXF and control groups. However, after adjusting for age and IOP, there was no difference in any of the biomechanical parameters among the four groups. CONCLUSION: Corneal biomechanical parameters measured on Corvis ST are not different between healthy controls and eyes with PXF and PXG. Since PXG is a high-pressure glaucoma, corneal biomechanics may not play an important role in its diagnosis and pathogenesis.
format Online
Article
Text
id pubmed-7350500
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-73505002020-07-15 A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology Pradhan, Zia S Deshmukh, Sujit Dixit, Shivani Gudetti, Praveena Devi, Sathi Webers, Carroll A B Rao, Harsha L Indian J Ophthalmol Original Article PURPOSE: To compare the corneal biomechanical parameters among pseudoexfoliation syndrome (PXF), pseudoexfoliation glaucoma (PXG), and healthy controls using Corvis Scheimpflug Technology (ST). METHODS: A prospective, cross-sectional study of 141 treatment-naïve eyes that underwent Corvis ST was conducted. These included 42 eyes with PXF, 17 eyes of PXF with ocular hypertension (PXF + OHT) defined as intraocular pressure (IOP) >21 mmHg without disc/field changes, 37 eyes with PXG, and 45 healthy controls. Corneal biomechanical parameters, which included corneal velocities, length of corneal applanated surface, deformation amplitude (DA), peak distance, and radius of curvature, were compared among the groups using analysis of variance models. RESULTS: The four groups were demographically similar. The mean IOP was lower in the controls (15.6 ± 3 mmHg) and PXF group (16.0 ± 3 mmHg) compared to the other two groups (>24 mmHg). Corneal pachymetry was similar across the four groups. Mean DA was significantly lower (P < 0.0001) in the PXG group (0.91 ± 0.18 mm) and the PXF + OHT group (0.94 ± 0.13 mm) when compared to the PXF (1.10 ± 0.11 mm) and control groups (1.12 ± 0.14 mm). Corneal velocities were also found to be statistically significantly lower in PXG and PXF + OHT compared to the PXF and control groups. However, after adjusting for age and IOP, there was no difference in any of the biomechanical parameters among the four groups. CONCLUSION: Corneal biomechanical parameters measured on Corvis ST are not different between healthy controls and eyes with PXF and PXG. Since PXG is a high-pressure glaucoma, corneal biomechanics may not play an important role in its diagnosis and pathogenesis. Wolters Kluwer - Medknow 2020-05 2020-04-20 /pmc/articles/PMC7350500/ /pubmed/32317447 http://dx.doi.org/10.4103/ijo.IJO_1550_19 Text en Copyright: © 2020 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Pradhan, Zia S
Deshmukh, Sujit
Dixit, Shivani
Gudetti, Praveena
Devi, Sathi
Webers, Carroll A B
Rao, Harsha L
A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title_full A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title_fullStr A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title_full_unstemmed A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title_short A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title_sort comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using corvis® scheimpflug technology
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7350500/
https://www.ncbi.nlm.nih.gov/pubmed/32317447
http://dx.doi.org/10.4103/ijo.IJO_1550_19
work_keys_str_mv AT pradhanzias acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT deshmukhsujit acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT dixitshivani acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT gudettipraveena acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT devisathi acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT weberscarrollab acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT raoharshal acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT pradhanzias comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT deshmukhsujit comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT dixitshivani comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT gudettipraveena comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT devisathi comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT weberscarrollab comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT raoharshal comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology