Cargando…
REPLICCAR II Study: Data quality audit in the Paulista Cardiovascular Surgery Registry
The quality of data in electronic healthcare databases is a critical component when used for research and health practice. The aim of the present study was to assess the data quality in the Paulista Cardiovascular Surgery Registry II (REPLICCAR II) using two different audit methods, direct and indir...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7351197/ https://www.ncbi.nlm.nih.gov/pubmed/32649718 http://dx.doi.org/10.1371/journal.pone.0223343 |
_version_ | 1783557404425715712 |
---|---|
author | Orlandi, Bianca Maria Maglia Mejia, Omar Asdrúbal Vilca Borgomoni, Gabrielle Barbosa Goncharov, Maxim Rocha, Kenji Nakahara Bassolli, Lucas Melo de Barros e Silva, Pedro Gabriel Nakazone, Marcelo Arruda Sousa, Alexandre Campagnucci, Valquíria Pelisser de Sousa Vilarinho, Karlos Alexandre Katz, Marcelo Tiveron, Marcos Gradim Arrais dos Santos, Magaly Lisboa, Luiz Augusto Ferreira Dallan, Luis Alberto de Oliveira Jatene, Fábio Biscegli |
author_facet | Orlandi, Bianca Maria Maglia Mejia, Omar Asdrúbal Vilca Borgomoni, Gabrielle Barbosa Goncharov, Maxim Rocha, Kenji Nakahara Bassolli, Lucas Melo de Barros e Silva, Pedro Gabriel Nakazone, Marcelo Arruda Sousa, Alexandre Campagnucci, Valquíria Pelisser de Sousa Vilarinho, Karlos Alexandre Katz, Marcelo Tiveron, Marcos Gradim Arrais dos Santos, Magaly Lisboa, Luiz Augusto Ferreira Dallan, Luis Alberto de Oliveira Jatene, Fábio Biscegli |
author_sort | Orlandi, Bianca Maria Maglia |
collection | PubMed |
description | The quality of data in electronic healthcare databases is a critical component when used for research and health practice. The aim of the present study was to assess the data quality in the Paulista Cardiovascular Surgery Registry II (REPLICCAR II) using two different audit methods, direct and indirect. The REPLICCAR II database contains data from 9 hospitals in São Paulo State with over 700 variables for 2229 surgical patients. The data collection was performed in REDCap platform using trained data managers to abstract information. We directly audited a random sample (n = 107) of the data collected after 6 months and indirectly audited the entire sample after 1 year of data collection. The indirect audit was performed using the data management tools in REDCap platform. We computed a modified Aggregate Data Quality Score (ADQ) previously reported by Salati et al. (2015). The agreement between data elements was good for categorical data (Cohen κ = 0.7, 95%CI = 0.59–0.83). For continuous data, the intraclass coefficient (ICC) for only 2 out of 15 continuous variables had an ICC < 0.9. In the indirect audit, 77% of the selected variables (n = 23) had a good ADQ score for completeness and accuracy. Data entry in the REPLICCAR II database proved to be satisfactory and showed competence and reliable data for research in cardiovascular surgery in Brazil. |
format | Online Article Text |
id | pubmed-7351197 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-73511972020-07-22 REPLICCAR II Study: Data quality audit in the Paulista Cardiovascular Surgery Registry Orlandi, Bianca Maria Maglia Mejia, Omar Asdrúbal Vilca Borgomoni, Gabrielle Barbosa Goncharov, Maxim Rocha, Kenji Nakahara Bassolli, Lucas Melo de Barros e Silva, Pedro Gabriel Nakazone, Marcelo Arruda Sousa, Alexandre Campagnucci, Valquíria Pelisser de Sousa Vilarinho, Karlos Alexandre Katz, Marcelo Tiveron, Marcos Gradim Arrais dos Santos, Magaly Lisboa, Luiz Augusto Ferreira Dallan, Luis Alberto de Oliveira Jatene, Fábio Biscegli PLoS One Research Article The quality of data in electronic healthcare databases is a critical component when used for research and health practice. The aim of the present study was to assess the data quality in the Paulista Cardiovascular Surgery Registry II (REPLICCAR II) using two different audit methods, direct and indirect. The REPLICCAR II database contains data from 9 hospitals in São Paulo State with over 700 variables for 2229 surgical patients. The data collection was performed in REDCap platform using trained data managers to abstract information. We directly audited a random sample (n = 107) of the data collected after 6 months and indirectly audited the entire sample after 1 year of data collection. The indirect audit was performed using the data management tools in REDCap platform. We computed a modified Aggregate Data Quality Score (ADQ) previously reported by Salati et al. (2015). The agreement between data elements was good for categorical data (Cohen κ = 0.7, 95%CI = 0.59–0.83). For continuous data, the intraclass coefficient (ICC) for only 2 out of 15 continuous variables had an ICC < 0.9. In the indirect audit, 77% of the selected variables (n = 23) had a good ADQ score for completeness and accuracy. Data entry in the REPLICCAR II database proved to be satisfactory and showed competence and reliable data for research in cardiovascular surgery in Brazil. Public Library of Science 2020-07-10 /pmc/articles/PMC7351197/ /pubmed/32649718 http://dx.doi.org/10.1371/journal.pone.0223343 Text en © 2020 Orlandi et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Orlandi, Bianca Maria Maglia Mejia, Omar Asdrúbal Vilca Borgomoni, Gabrielle Barbosa Goncharov, Maxim Rocha, Kenji Nakahara Bassolli, Lucas Melo de Barros e Silva, Pedro Gabriel Nakazone, Marcelo Arruda Sousa, Alexandre Campagnucci, Valquíria Pelisser de Sousa Vilarinho, Karlos Alexandre Katz, Marcelo Tiveron, Marcos Gradim Arrais dos Santos, Magaly Lisboa, Luiz Augusto Ferreira Dallan, Luis Alberto de Oliveira Jatene, Fábio Biscegli REPLICCAR II Study: Data quality audit in the Paulista Cardiovascular Surgery Registry |
title | REPLICCAR II Study: Data quality audit in the Paulista Cardiovascular Surgery Registry |
title_full | REPLICCAR II Study: Data quality audit in the Paulista Cardiovascular Surgery Registry |
title_fullStr | REPLICCAR II Study: Data quality audit in the Paulista Cardiovascular Surgery Registry |
title_full_unstemmed | REPLICCAR II Study: Data quality audit in the Paulista Cardiovascular Surgery Registry |
title_short | REPLICCAR II Study: Data quality audit in the Paulista Cardiovascular Surgery Registry |
title_sort | repliccar ii study: data quality audit in the paulista cardiovascular surgery registry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7351197/ https://www.ncbi.nlm.nih.gov/pubmed/32649718 http://dx.doi.org/10.1371/journal.pone.0223343 |
work_keys_str_mv | AT orlandibiancamariamaglia repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT mejiaomarasdrubalvilca repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT borgomonigabriellebarbosa repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT goncharovmaxim repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT rochakenjinakahara repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT bassollilucas repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT melodebarrosesilvapedrogabriel repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT nakazonemarceloarruda repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT sousaalexandre repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT campagnuccivalquiriapelisser repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT desousavilarinhokarlosalexandre repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT katzmarcelo repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT tiveronmarcosgradim repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT arraisdossantosmagaly repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT lisboaluizaugustoferreira repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT dallanluisalbertodeoliveira repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT jatenefabiobiscegli repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry AT repliccariistudydataqualityauditinthepaulistacardiovascularsurgeryregistry |