Cargando…

Relationship between Implant Length and Implant Stability of Single-Implant Restorations: A 12-Month Follow-Up Clinical Study

Background and Objectives: Implant stability in vivo is contingent on multiple factors, such as bone structure, instrument positioning and implant surface modifications, implant diameter, and implant length. Resonance-frequency analysis is considered a non-invasive, reliable, predictable, and object...

Descripción completa

Detalles Bibliográficos
Autores principales: Aragoneses, Juan Manuel, Aragoneses, Javier, Brugal, Vanessa Arlette, Gomez, Margarita, Suarez, Ana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7353855/
https://www.ncbi.nlm.nih.gov/pubmed/32471305
http://dx.doi.org/10.3390/medicina56060263
_version_ 1783557970960842752
author Aragoneses, Juan Manuel
Aragoneses, Javier
Brugal, Vanessa Arlette
Gomez, Margarita
Suarez, Ana
author_facet Aragoneses, Juan Manuel
Aragoneses, Javier
Brugal, Vanessa Arlette
Gomez, Margarita
Suarez, Ana
author_sort Aragoneses, Juan Manuel
collection PubMed
description Background and Objectives: Implant stability in vivo is contingent on multiple factors, such as bone structure, instrument positioning and implant surface modifications, implant diameter, and implant length. Resonance-frequency analysis is considered a non-invasive, reliable, predictable, and objective method by which to evaluate implant stability, due to its correlation with bone-to-implant contact. The purpose of this study was to evaluate the effect of implant length on the primary and secondary stability of single-implant crown rehabilitations, as measured by resonance-frequency analysis at different times. Materials and Methods: Implants of 10 and 11.5 mm were placed, and the resonance frequency was measured at the time of surgery (T0), as well as at 3 (T1), 6 (T2), and 12 (T3) months post-surgery. Results: A total of 559 implants were placed in 195 patients. Significant differences were observed when comparing the implant stability quotient (ISQ) values at T1, with values for 10-mm implants being greater than those for 11.5-mm implants (p = 0.035). These differences were also observed when comparing ISQ values for buccal and lingual areas. At T0, T2, and T3, no significant differences in ISQ values were observed. The use of 10-mm implants in the anterior maxilla yielded significantly greater values at T0 (p = 0.018) and T1 (p = 0.031) when compared with 11.5-mm implants. Significant differences in measurements were observed only for buccal areas (p = 0.005; p = 0.018). When comparing the sample lengths and sex, women with 11.5-mm implants showed significantly lower results than those with 10-mm implants (p < 0.001). Conclusions: There is a direct relationship between implants of a smaller length and greater ISQ values, with this relationship being most evident in the maxilla and in women.
format Online
Article
Text
id pubmed-7353855
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73538552020-07-21 Relationship between Implant Length and Implant Stability of Single-Implant Restorations: A 12-Month Follow-Up Clinical Study Aragoneses, Juan Manuel Aragoneses, Javier Brugal, Vanessa Arlette Gomez, Margarita Suarez, Ana Medicina (Kaunas) Article Background and Objectives: Implant stability in vivo is contingent on multiple factors, such as bone structure, instrument positioning and implant surface modifications, implant diameter, and implant length. Resonance-frequency analysis is considered a non-invasive, reliable, predictable, and objective method by which to evaluate implant stability, due to its correlation with bone-to-implant contact. The purpose of this study was to evaluate the effect of implant length on the primary and secondary stability of single-implant crown rehabilitations, as measured by resonance-frequency analysis at different times. Materials and Methods: Implants of 10 and 11.5 mm were placed, and the resonance frequency was measured at the time of surgery (T0), as well as at 3 (T1), 6 (T2), and 12 (T3) months post-surgery. Results: A total of 559 implants were placed in 195 patients. Significant differences were observed when comparing the implant stability quotient (ISQ) values at T1, with values for 10-mm implants being greater than those for 11.5-mm implants (p = 0.035). These differences were also observed when comparing ISQ values for buccal and lingual areas. At T0, T2, and T3, no significant differences in ISQ values were observed. The use of 10-mm implants in the anterior maxilla yielded significantly greater values at T0 (p = 0.018) and T1 (p = 0.031) when compared with 11.5-mm implants. Significant differences in measurements were observed only for buccal areas (p = 0.005; p = 0.018). When comparing the sample lengths and sex, women with 11.5-mm implants showed significantly lower results than those with 10-mm implants (p < 0.001). Conclusions: There is a direct relationship between implants of a smaller length and greater ISQ values, with this relationship being most evident in the maxilla and in women. MDPI 2020-05-27 /pmc/articles/PMC7353855/ /pubmed/32471305 http://dx.doi.org/10.3390/medicina56060263 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Aragoneses, Juan Manuel
Aragoneses, Javier
Brugal, Vanessa Arlette
Gomez, Margarita
Suarez, Ana
Relationship between Implant Length and Implant Stability of Single-Implant Restorations: A 12-Month Follow-Up Clinical Study
title Relationship between Implant Length and Implant Stability of Single-Implant Restorations: A 12-Month Follow-Up Clinical Study
title_full Relationship between Implant Length and Implant Stability of Single-Implant Restorations: A 12-Month Follow-Up Clinical Study
title_fullStr Relationship between Implant Length and Implant Stability of Single-Implant Restorations: A 12-Month Follow-Up Clinical Study
title_full_unstemmed Relationship between Implant Length and Implant Stability of Single-Implant Restorations: A 12-Month Follow-Up Clinical Study
title_short Relationship between Implant Length and Implant Stability of Single-Implant Restorations: A 12-Month Follow-Up Clinical Study
title_sort relationship between implant length and implant stability of single-implant restorations: a 12-month follow-up clinical study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7353855/
https://www.ncbi.nlm.nih.gov/pubmed/32471305
http://dx.doi.org/10.3390/medicina56060263
work_keys_str_mv AT aragonesesjuanmanuel relationshipbetweenimplantlengthandimplantstabilityofsingleimplantrestorationsa12monthfollowupclinicalstudy
AT aragonesesjavier relationshipbetweenimplantlengthandimplantstabilityofsingleimplantrestorationsa12monthfollowupclinicalstudy
AT brugalvanessaarlette relationshipbetweenimplantlengthandimplantstabilityofsingleimplantrestorationsa12monthfollowupclinicalstudy
AT gomezmargarita relationshipbetweenimplantlengthandimplantstabilityofsingleimplantrestorationsa12monthfollowupclinicalstudy
AT suarezana relationshipbetweenimplantlengthandimplantstabilityofsingleimplantrestorationsa12monthfollowupclinicalstudy