Cargando…
Semiquantitation of Paralytic Shellfish Toxins by Hydrophilic Interaction Liquid Chromatography-Mass Spectrometry Using Relative Molar Response Factors
Paralytic shellfish toxins (PSTs) are a complex class of analogs of the potent neurotoxin saxitoxin (STX). Since calibration standards are not available for many PSTs, including C-11 hydroxyl analogs called M-toxins, accurate quantitation by liquid chromatography–mass spectrometry (LC-MS) can be cha...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7354571/ https://www.ncbi.nlm.nih.gov/pubmed/32560098 http://dx.doi.org/10.3390/toxins12060398 |
_version_ | 1783558115677962240 |
---|---|
author | Qiu, Jiangbing Wright, Elliott J. Thomas, Krista Li, Aifeng McCarron, Pearse Beach, Daniel G. |
author_facet | Qiu, Jiangbing Wright, Elliott J. Thomas, Krista Li, Aifeng McCarron, Pearse Beach, Daniel G. |
author_sort | Qiu, Jiangbing |
collection | PubMed |
description | Paralytic shellfish toxins (PSTs) are a complex class of analogs of the potent neurotoxin saxitoxin (STX). Since calibration standards are not available for many PSTs, including C-11 hydroxyl analogs called M-toxins, accurate quantitation by liquid chromatography–mass spectrometry (LC-MS) can be challenging. In the absence of standards, PSTs are often semiquantitated using standards of a different analog (e.g., STX), an approach with a high degree of uncertainty due to the highly variable sensitivity between analytes in electrospray ionization. Here, relative molar response factors (RMRs) were investigated for a broad range of PSTs using common LC-MS approaches in order to improve the quantitation of PSTs for which standards are unavailable. First, several M-toxins (M1-M6, M9 and dcM6) were semipurified from shellfish using preparative gel filtration chromatography and quantitated using LC-charged aerosol detection (LC-CAD). The RMRs of PST certified reference materials (CRMs) and M-toxins were then determined using selective reaction monitoring LC-MS/MS and full scan LC-high-resolution MS (LC-HRMS) methods in positive and negative electrospray ionization. In general, RMRs for PSTs with similar chemical structures were comparable, but varied significantly between subclasses, with M-toxins showing the lowest sensitivity. For example, STX showed a greater than 50-fold higher RMR than M4 and M6 by LC-HRMS. The MS instrument, scan mode and polarity also had significant impacts on RMRs and should be carefully considered when semiquantitating PSTs by LC-MS. As a demonstration of their utility, the RMRs determined were applied to the semiquantitation of PSTs in contaminated mussels, showing good agreement with results from calibration with CRMs. |
format | Online Article Text |
id | pubmed-7354571 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-73545712020-07-23 Semiquantitation of Paralytic Shellfish Toxins by Hydrophilic Interaction Liquid Chromatography-Mass Spectrometry Using Relative Molar Response Factors Qiu, Jiangbing Wright, Elliott J. Thomas, Krista Li, Aifeng McCarron, Pearse Beach, Daniel G. Toxins (Basel) Article Paralytic shellfish toxins (PSTs) are a complex class of analogs of the potent neurotoxin saxitoxin (STX). Since calibration standards are not available for many PSTs, including C-11 hydroxyl analogs called M-toxins, accurate quantitation by liquid chromatography–mass spectrometry (LC-MS) can be challenging. In the absence of standards, PSTs are often semiquantitated using standards of a different analog (e.g., STX), an approach with a high degree of uncertainty due to the highly variable sensitivity between analytes in electrospray ionization. Here, relative molar response factors (RMRs) were investigated for a broad range of PSTs using common LC-MS approaches in order to improve the quantitation of PSTs for which standards are unavailable. First, several M-toxins (M1-M6, M9 and dcM6) were semipurified from shellfish using preparative gel filtration chromatography and quantitated using LC-charged aerosol detection (LC-CAD). The RMRs of PST certified reference materials (CRMs) and M-toxins were then determined using selective reaction monitoring LC-MS/MS and full scan LC-high-resolution MS (LC-HRMS) methods in positive and negative electrospray ionization. In general, RMRs for PSTs with similar chemical structures were comparable, but varied significantly between subclasses, with M-toxins showing the lowest sensitivity. For example, STX showed a greater than 50-fold higher RMR than M4 and M6 by LC-HRMS. The MS instrument, scan mode and polarity also had significant impacts on RMRs and should be carefully considered when semiquantitating PSTs by LC-MS. As a demonstration of their utility, the RMRs determined were applied to the semiquantitation of PSTs in contaminated mussels, showing good agreement with results from calibration with CRMs. MDPI 2020-06-16 /pmc/articles/PMC7354571/ /pubmed/32560098 http://dx.doi.org/10.3390/toxins12060398 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Qiu, Jiangbing Wright, Elliott J. Thomas, Krista Li, Aifeng McCarron, Pearse Beach, Daniel G. Semiquantitation of Paralytic Shellfish Toxins by Hydrophilic Interaction Liquid Chromatography-Mass Spectrometry Using Relative Molar Response Factors |
title | Semiquantitation of Paralytic Shellfish Toxins by Hydrophilic Interaction Liquid Chromatography-Mass Spectrometry Using Relative Molar Response Factors |
title_full | Semiquantitation of Paralytic Shellfish Toxins by Hydrophilic Interaction Liquid Chromatography-Mass Spectrometry Using Relative Molar Response Factors |
title_fullStr | Semiquantitation of Paralytic Shellfish Toxins by Hydrophilic Interaction Liquid Chromatography-Mass Spectrometry Using Relative Molar Response Factors |
title_full_unstemmed | Semiquantitation of Paralytic Shellfish Toxins by Hydrophilic Interaction Liquid Chromatography-Mass Spectrometry Using Relative Molar Response Factors |
title_short | Semiquantitation of Paralytic Shellfish Toxins by Hydrophilic Interaction Liquid Chromatography-Mass Spectrometry Using Relative Molar Response Factors |
title_sort | semiquantitation of paralytic shellfish toxins by hydrophilic interaction liquid chromatography-mass spectrometry using relative molar response factors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7354571/ https://www.ncbi.nlm.nih.gov/pubmed/32560098 http://dx.doi.org/10.3390/toxins12060398 |
work_keys_str_mv | AT qiujiangbing semiquantitationofparalyticshellfishtoxinsbyhydrophilicinteractionliquidchromatographymassspectrometryusingrelativemolarresponsefactors AT wrightelliottj semiquantitationofparalyticshellfishtoxinsbyhydrophilicinteractionliquidchromatographymassspectrometryusingrelativemolarresponsefactors AT thomaskrista semiquantitationofparalyticshellfishtoxinsbyhydrophilicinteractionliquidchromatographymassspectrometryusingrelativemolarresponsefactors AT liaifeng semiquantitationofparalyticshellfishtoxinsbyhydrophilicinteractionliquidchromatographymassspectrometryusingrelativemolarresponsefactors AT mccarronpearse semiquantitationofparalyticshellfishtoxinsbyhydrophilicinteractionliquidchromatographymassspectrometryusingrelativemolarresponsefactors AT beachdanielg semiquantitationofparalyticshellfishtoxinsbyhydrophilicinteractionliquidchromatographymassspectrometryusingrelativemolarresponsefactors |