Cargando…

Middle Cerebral Artery Doppler Velocimetry for the Diagnosis of Twin Anemia Polycythemia Sequence: A Systematic Review

Twin anemia polycythemia sequence (TAPS) is a rare complication of monochorionic diamniotic (MCDA) twins. Middle cerebral artery peak systolic velocity (MCA-PSV) measurements are used to screen for TAPS while fetal or neonatal hemoglobin levels are required for definitive diagnosis. We sought to per...

Descripción completa

Detalles Bibliográficos
Autores principales: Brock, Clifton O., Bergh, Eric P., Moise,, Kenneth J., Johnson, Anthony, Hernandez-Andrade, Edgar, Lai, Dejian, Papanna, Ramesha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7355756/
https://www.ncbi.nlm.nih.gov/pubmed/32512796
http://dx.doi.org/10.3390/jcm9061735
_version_ 1783558349203177472
author Brock, Clifton O.
Bergh, Eric P.
Moise,, Kenneth J.
Johnson, Anthony
Hernandez-Andrade, Edgar
Lai, Dejian
Papanna, Ramesha
author_facet Brock, Clifton O.
Bergh, Eric P.
Moise,, Kenneth J.
Johnson, Anthony
Hernandez-Andrade, Edgar
Lai, Dejian
Papanna, Ramesha
author_sort Brock, Clifton O.
collection PubMed
description Twin anemia polycythemia sequence (TAPS) is a rare complication of monochorionic diamniotic (MCDA) twins. Middle cerebral artery peak systolic velocity (MCA-PSV) measurements are used to screen for TAPS while fetal or neonatal hemoglobin levels are required for definitive diagnosis. We sought to perform a systematic review of the efficacy of MCA-PSV in diagnosing TAPS. Search criteria were developed using relevant terms to query the Pubmed, Embase, and SCOPUS electronic databases. Publications reporting diagnostic characteristics of MCA-PSV measurements (i.e., sensitivity, specificity or receiver operator curves) were included. Each article was assessed for bias using the Quality Assessment of Diagnostic Accuracy Studies II (QUADAS II) tool. Results were assessed for uniformity to determine whether meta-analysis was feasible. Data were presented in tabular form. Among publications, five met the inclusion criteria. QUADAS II analysis revealed that four of the publications were highly likely to have bias in multiple areas. Meta-analysis was precluded by non-uniformity between definitions of TAPS by MCA-PSV and neonatal or fetal hemoglobin levels. High-quality prospective studies with consistent definitions and ultrasound surveillance protocols are still required to determine the efficacy of MCA-PSV in diagnosing TAPS. Other ultrasound findings (e.g., placenta echogenicity discordance) may augment Doppler studies.
format Online
Article
Text
id pubmed-7355756
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73557562020-07-23 Middle Cerebral Artery Doppler Velocimetry for the Diagnosis of Twin Anemia Polycythemia Sequence: A Systematic Review Brock, Clifton O. Bergh, Eric P. Moise,, Kenneth J. Johnson, Anthony Hernandez-Andrade, Edgar Lai, Dejian Papanna, Ramesha J Clin Med Article Twin anemia polycythemia sequence (TAPS) is a rare complication of monochorionic diamniotic (MCDA) twins. Middle cerebral artery peak systolic velocity (MCA-PSV) measurements are used to screen for TAPS while fetal or neonatal hemoglobin levels are required for definitive diagnosis. We sought to perform a systematic review of the efficacy of MCA-PSV in diagnosing TAPS. Search criteria were developed using relevant terms to query the Pubmed, Embase, and SCOPUS electronic databases. Publications reporting diagnostic characteristics of MCA-PSV measurements (i.e., sensitivity, specificity or receiver operator curves) were included. Each article was assessed for bias using the Quality Assessment of Diagnostic Accuracy Studies II (QUADAS II) tool. Results were assessed for uniformity to determine whether meta-analysis was feasible. Data were presented in tabular form. Among publications, five met the inclusion criteria. QUADAS II analysis revealed that four of the publications were highly likely to have bias in multiple areas. Meta-analysis was precluded by non-uniformity between definitions of TAPS by MCA-PSV and neonatal or fetal hemoglobin levels. High-quality prospective studies with consistent definitions and ultrasound surveillance protocols are still required to determine the efficacy of MCA-PSV in diagnosing TAPS. Other ultrasound findings (e.g., placenta echogenicity discordance) may augment Doppler studies. MDPI 2020-06-04 /pmc/articles/PMC7355756/ /pubmed/32512796 http://dx.doi.org/10.3390/jcm9061735 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Brock, Clifton O.
Bergh, Eric P.
Moise,, Kenneth J.
Johnson, Anthony
Hernandez-Andrade, Edgar
Lai, Dejian
Papanna, Ramesha
Middle Cerebral Artery Doppler Velocimetry for the Diagnosis of Twin Anemia Polycythemia Sequence: A Systematic Review
title Middle Cerebral Artery Doppler Velocimetry for the Diagnosis of Twin Anemia Polycythemia Sequence: A Systematic Review
title_full Middle Cerebral Artery Doppler Velocimetry for the Diagnosis of Twin Anemia Polycythemia Sequence: A Systematic Review
title_fullStr Middle Cerebral Artery Doppler Velocimetry for the Diagnosis of Twin Anemia Polycythemia Sequence: A Systematic Review
title_full_unstemmed Middle Cerebral Artery Doppler Velocimetry for the Diagnosis of Twin Anemia Polycythemia Sequence: A Systematic Review
title_short Middle Cerebral Artery Doppler Velocimetry for the Diagnosis of Twin Anemia Polycythemia Sequence: A Systematic Review
title_sort middle cerebral artery doppler velocimetry for the diagnosis of twin anemia polycythemia sequence: a systematic review
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7355756/
https://www.ncbi.nlm.nih.gov/pubmed/32512796
http://dx.doi.org/10.3390/jcm9061735
work_keys_str_mv AT brockcliftono middlecerebralarterydopplervelocimetryforthediagnosisoftwinanemiapolycythemiasequenceasystematicreview
AT berghericp middlecerebralarterydopplervelocimetryforthediagnosisoftwinanemiapolycythemiasequenceasystematicreview
AT moisekennethj middlecerebralarterydopplervelocimetryforthediagnosisoftwinanemiapolycythemiasequenceasystematicreview
AT johnsonanthony middlecerebralarterydopplervelocimetryforthediagnosisoftwinanemiapolycythemiasequenceasystematicreview
AT hernandezandradeedgar middlecerebralarterydopplervelocimetryforthediagnosisoftwinanemiapolycythemiasequenceasystematicreview
AT laidejian middlecerebralarterydopplervelocimetryforthediagnosisoftwinanemiapolycythemiasequenceasystematicreview
AT papannaramesha middlecerebralarterydopplervelocimetryforthediagnosisoftwinanemiapolycythemiasequenceasystematicreview