Cargando…
Magnetic Solid-Phase Extraction Based on Poly 4-Vinyl Pyridine for HPLC-FLD Analysis of Naproxen in Urine Samples
A magnetic solid phase extraction technique followed by liquid chromatography with a fluorescence detector for naproxen analysis in human urine samples was developed. The method includes the extraction of naproxen with a magnetic solid synthetized with magnetite and poly 4-vinylpriridine, followed b...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7355941/ https://www.ncbi.nlm.nih.gov/pubmed/32630475 http://dx.doi.org/10.3390/molecules25122924 |
_version_ | 1783558392095178752 |
---|---|
author | Escamilla-Lara, Karen A. Heredia, Ana C. Peña-Alvarez, Araceli Ibarra, Israel S. Barrado, Enrique Rodriguez, Jose A. |
author_facet | Escamilla-Lara, Karen A. Heredia, Ana C. Peña-Alvarez, Araceli Ibarra, Israel S. Barrado, Enrique Rodriguez, Jose A. |
author_sort | Escamilla-Lara, Karen A. |
collection | PubMed |
description | A magnetic solid phase extraction technique followed by liquid chromatography with a fluorescence detector for naproxen analysis in human urine samples was developed. The method includes the extraction of naproxen with a magnetic solid synthetized with magnetite and poly 4-vinylpriridine, followed by the magnetic separation of the solid phase and desorption of the analyte with methanol. Under optimal conditions, the linear range of the calibration curve was 0.05–0.60 μg L(−1), with a limit of detection of 0.02 μg L(−1). In all cases values of repeatability were lower than 5.0% with recoveries of 99.4 ± 1.3%. Precision and accuracy values are adequate for naproxen (Npx) analysis in urine samples. |
format | Online Article Text |
id | pubmed-7355941 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-73559412020-07-22 Magnetic Solid-Phase Extraction Based on Poly 4-Vinyl Pyridine for HPLC-FLD Analysis of Naproxen in Urine Samples Escamilla-Lara, Karen A. Heredia, Ana C. Peña-Alvarez, Araceli Ibarra, Israel S. Barrado, Enrique Rodriguez, Jose A. Molecules Article A magnetic solid phase extraction technique followed by liquid chromatography with a fluorescence detector for naproxen analysis in human urine samples was developed. The method includes the extraction of naproxen with a magnetic solid synthetized with magnetite and poly 4-vinylpriridine, followed by the magnetic separation of the solid phase and desorption of the analyte with methanol. Under optimal conditions, the linear range of the calibration curve was 0.05–0.60 μg L(−1), with a limit of detection of 0.02 μg L(−1). In all cases values of repeatability were lower than 5.0% with recoveries of 99.4 ± 1.3%. Precision and accuracy values are adequate for naproxen (Npx) analysis in urine samples. MDPI 2020-06-25 /pmc/articles/PMC7355941/ /pubmed/32630475 http://dx.doi.org/10.3390/molecules25122924 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Escamilla-Lara, Karen A. Heredia, Ana C. Peña-Alvarez, Araceli Ibarra, Israel S. Barrado, Enrique Rodriguez, Jose A. Magnetic Solid-Phase Extraction Based on Poly 4-Vinyl Pyridine for HPLC-FLD Analysis of Naproxen in Urine Samples |
title | Magnetic Solid-Phase Extraction Based on Poly 4-Vinyl Pyridine for HPLC-FLD Analysis of Naproxen in Urine Samples |
title_full | Magnetic Solid-Phase Extraction Based on Poly 4-Vinyl Pyridine for HPLC-FLD Analysis of Naproxen in Urine Samples |
title_fullStr | Magnetic Solid-Phase Extraction Based on Poly 4-Vinyl Pyridine for HPLC-FLD Analysis of Naproxen in Urine Samples |
title_full_unstemmed | Magnetic Solid-Phase Extraction Based on Poly 4-Vinyl Pyridine for HPLC-FLD Analysis of Naproxen in Urine Samples |
title_short | Magnetic Solid-Phase Extraction Based on Poly 4-Vinyl Pyridine for HPLC-FLD Analysis of Naproxen in Urine Samples |
title_sort | magnetic solid-phase extraction based on poly 4-vinyl pyridine for hplc-fld analysis of naproxen in urine samples |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7355941/ https://www.ncbi.nlm.nih.gov/pubmed/32630475 http://dx.doi.org/10.3390/molecules25122924 |
work_keys_str_mv | AT escamillalarakarena magneticsolidphaseextractionbasedonpoly4vinylpyridineforhplcfldanalysisofnaproxeninurinesamples AT herediaanac magneticsolidphaseextractionbasedonpoly4vinylpyridineforhplcfldanalysisofnaproxeninurinesamples AT penaalvarezaraceli magneticsolidphaseextractionbasedonpoly4vinylpyridineforhplcfldanalysisofnaproxeninurinesamples AT ibarraisraels magneticsolidphaseextractionbasedonpoly4vinylpyridineforhplcfldanalysisofnaproxeninurinesamples AT barradoenrique magneticsolidphaseextractionbasedonpoly4vinylpyridineforhplcfldanalysisofnaproxeninurinesamples AT rodriguezjosea magneticsolidphaseextractionbasedonpoly4vinylpyridineforhplcfldanalysisofnaproxeninurinesamples |