Cargando…

Identification of malignant early repolarization pattern by late QRS activity in high‐resolution magnetocardiography

BACKGROUND: The early repolarization pattern (ERP) in electrocardiography (ECG) has been considered as a risk for ventricular fibrillation (VF), but effective methods for identification of malignant ERP are still required. We investigated whether high spatiotemporal resolution 64‐channel magnetocard...

Descripción completa

Detalles Bibliográficos
Autores principales: Iwakami, Naotsugu, Aiba, Takeshi, Kamakura, Shiro, Takaki, Hiroshi, Furukawa, Toshiaki A., Sato, Tosiya, Sun, Wenxu, Shishido, Toshiaki, Nishimura, Kunihiro, Yamada‐Inoue, Yuko, Nagase, Satoshi, Shimizu, Wataru, Yasuda, Satoshi, Sugimachi, Masaru, Kusano, Kengo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7358799/
https://www.ncbi.nlm.nih.gov/pubmed/31955494
http://dx.doi.org/10.1111/anec.12741
Descripción
Sumario:BACKGROUND: The early repolarization pattern (ERP) in electrocardiography (ECG) has been considered as a risk for ventricular fibrillation (VF), but effective methods for identification of malignant ERP are still required. We investigated whether high spatiotemporal resolution 64‐channel magnetocardiography (MCG) would enable distinction between benign and malignant ERPs. METHODS: Among all 2,636 subjects who received MCG in our facility, we identified 116 subjects (43 ± 18 years old, 54% male) with inferior and/or lateral ERP in ECG and without structural heart disease, including 13 survivors of VF (ERP‐VF(+)) and 103 with no history of VF (ERP‐VF(−)). We measured the following MCG parameters in a time‐domain waveform of relative current magnitude: (a) QRS duration (MCG‐QRSD), (b) root‐mean‐square of the last 40 ms (MCG‐RMS40), and (c) low amplitude (<10% of maximal) signal duration (MCG‐LAS). RESULTS: Compared to ERP‐VF(−), ERP‐VF(+) subjects presented a significantly longer MCG‐QRS (108 ± 24 vs. 91 ± 23 ms, p = .02) and lower MCG‐RMS40 (0.10 ± 0.08 vs. 0.25 ± 0.20, p = .01) but no difference in MCG‐LAS (38 ± 22 vs. 29 ± 23 ms, p = .17). MCG‐QRSD and MCG‐RMS40 showed significantly larger area under the ROC curve compared to J‐peak amplitude in ECG (0.72 and 0.71 vs. 0.50; p = .04 and 0.03). The sensitivity, specificity, and odds ratio for identifying VF(+) based on MCG‐QRSD ≥ 100 ms and MCG‐RMS40 ≤ 0.24 were 69%, 74%, and 6.33 (95% CI, 1.80–22.3), and 92%, 48%, and 10.9 (95% CI, 1.37–86.8), respectively. CONCLUSION: Magnetocardiography is an effective tool to distinguish malignant and benign ERPs.