Identification of malignant early repolarization pattern by late QRS activity in high‐resolution magnetocardiography

BACKGROUND: The early repolarization pattern (ERP) in electrocardiography (ECG) has been considered as a risk for ventricular fibrillation (VF), but effective methods for identification of malignant ERP are still required. We investigated whether high spatiotemporal resolution 64‐channel magnetocard...

Descripción completa

Detalles Bibliográficos
Autores principales: Iwakami, Naotsugu, Aiba, Takeshi, Kamakura, Shiro, Takaki, Hiroshi, Furukawa, Toshiaki A., Sato, Tosiya, Sun, Wenxu, Shishido, Toshiaki, Nishimura, Kunihiro, Yamada‐Inoue, Yuko, Nagase, Satoshi, Shimizu, Wataru, Yasuda, Satoshi, Sugimachi, Masaru, Kusano, Kengo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7358799/
https://www.ncbi.nlm.nih.gov/pubmed/31955494
http://dx.doi.org/10.1111/anec.12741
_version_ 1783558915867279360
author Iwakami, Naotsugu
Aiba, Takeshi
Kamakura, Shiro
Takaki, Hiroshi
Furukawa, Toshiaki A.
Sato, Tosiya
Sun, Wenxu
Shishido, Toshiaki
Nishimura, Kunihiro
Yamada‐Inoue, Yuko
Nagase, Satoshi
Shimizu, Wataru
Yasuda, Satoshi
Sugimachi, Masaru
Kusano, Kengo
author_facet Iwakami, Naotsugu
Aiba, Takeshi
Kamakura, Shiro
Takaki, Hiroshi
Furukawa, Toshiaki A.
Sato, Tosiya
Sun, Wenxu
Shishido, Toshiaki
Nishimura, Kunihiro
Yamada‐Inoue, Yuko
Nagase, Satoshi
Shimizu, Wataru
Yasuda, Satoshi
Sugimachi, Masaru
Kusano, Kengo
author_sort Iwakami, Naotsugu
collection PubMed
description BACKGROUND: The early repolarization pattern (ERP) in electrocardiography (ECG) has been considered as a risk for ventricular fibrillation (VF), but effective methods for identification of malignant ERP are still required. We investigated whether high spatiotemporal resolution 64‐channel magnetocardiography (MCG) would enable distinction between benign and malignant ERPs. METHODS: Among all 2,636 subjects who received MCG in our facility, we identified 116 subjects (43 ± 18 years old, 54% male) with inferior and/or lateral ERP in ECG and without structural heart disease, including 13 survivors of VF (ERP‐VF(+)) and 103 with no history of VF (ERP‐VF(−)). We measured the following MCG parameters in a time‐domain waveform of relative current magnitude: (a) QRS duration (MCG‐QRSD), (b) root‐mean‐square of the last 40 ms (MCG‐RMS40), and (c) low amplitude (<10% of maximal) signal duration (MCG‐LAS). RESULTS: Compared to ERP‐VF(−), ERP‐VF(+) subjects presented a significantly longer MCG‐QRS (108 ± 24 vs. 91 ± 23 ms, p = .02) and lower MCG‐RMS40 (0.10 ± 0.08 vs. 0.25 ± 0.20, p = .01) but no difference in MCG‐LAS (38 ± 22 vs. 29 ± 23 ms, p = .17). MCG‐QRSD and MCG‐RMS40 showed significantly larger area under the ROC curve compared to J‐peak amplitude in ECG (0.72 and 0.71 vs. 0.50; p = .04 and 0.03). The sensitivity, specificity, and odds ratio for identifying VF(+) based on MCG‐QRSD ≥ 100 ms and MCG‐RMS40 ≤ 0.24 were 69%, 74%, and 6.33 (95% CI, 1.80–22.3), and 92%, 48%, and 10.9 (95% CI, 1.37–86.8), respectively. CONCLUSION: Magnetocardiography is an effective tool to distinguish malignant and benign ERPs.
format Online
Article
Text
id pubmed-7358799
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-73587992020-07-17 Identification of malignant early repolarization pattern by late QRS activity in high‐resolution magnetocardiography Iwakami, Naotsugu Aiba, Takeshi Kamakura, Shiro Takaki, Hiroshi Furukawa, Toshiaki A. Sato, Tosiya Sun, Wenxu Shishido, Toshiaki Nishimura, Kunihiro Yamada‐Inoue, Yuko Nagase, Satoshi Shimizu, Wataru Yasuda, Satoshi Sugimachi, Masaru Kusano, Kengo Ann Noninvasive Electrocardiol New Technologies BACKGROUND: The early repolarization pattern (ERP) in electrocardiography (ECG) has been considered as a risk for ventricular fibrillation (VF), but effective methods for identification of malignant ERP are still required. We investigated whether high spatiotemporal resolution 64‐channel magnetocardiography (MCG) would enable distinction between benign and malignant ERPs. METHODS: Among all 2,636 subjects who received MCG in our facility, we identified 116 subjects (43 ± 18 years old, 54% male) with inferior and/or lateral ERP in ECG and without structural heart disease, including 13 survivors of VF (ERP‐VF(+)) and 103 with no history of VF (ERP‐VF(−)). We measured the following MCG parameters in a time‐domain waveform of relative current magnitude: (a) QRS duration (MCG‐QRSD), (b) root‐mean‐square of the last 40 ms (MCG‐RMS40), and (c) low amplitude (<10% of maximal) signal duration (MCG‐LAS). RESULTS: Compared to ERP‐VF(−), ERP‐VF(+) subjects presented a significantly longer MCG‐QRS (108 ± 24 vs. 91 ± 23 ms, p = .02) and lower MCG‐RMS40 (0.10 ± 0.08 vs. 0.25 ± 0.20, p = .01) but no difference in MCG‐LAS (38 ± 22 vs. 29 ± 23 ms, p = .17). MCG‐QRSD and MCG‐RMS40 showed significantly larger area under the ROC curve compared to J‐peak amplitude in ECG (0.72 and 0.71 vs. 0.50; p = .04 and 0.03). The sensitivity, specificity, and odds ratio for identifying VF(+) based on MCG‐QRSD ≥ 100 ms and MCG‐RMS40 ≤ 0.24 were 69%, 74%, and 6.33 (95% CI, 1.80–22.3), and 92%, 48%, and 10.9 (95% CI, 1.37–86.8), respectively. CONCLUSION: Magnetocardiography is an effective tool to distinguish malignant and benign ERPs. John Wiley and Sons Inc. 2020-01-19 /pmc/articles/PMC7358799/ /pubmed/31955494 http://dx.doi.org/10.1111/anec.12741 Text en © 2020 The Authors. Annals of Noninvasive Electrocardiology published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle New Technologies
Iwakami, Naotsugu
Aiba, Takeshi
Kamakura, Shiro
Takaki, Hiroshi
Furukawa, Toshiaki A.
Sato, Tosiya
Sun, Wenxu
Shishido, Toshiaki
Nishimura, Kunihiro
Yamada‐Inoue, Yuko
Nagase, Satoshi
Shimizu, Wataru
Yasuda, Satoshi
Sugimachi, Masaru
Kusano, Kengo
Identification of malignant early repolarization pattern by late QRS activity in high‐resolution magnetocardiography
title Identification of malignant early repolarization pattern by late QRS activity in high‐resolution magnetocardiography
title_full Identification of malignant early repolarization pattern by late QRS activity in high‐resolution magnetocardiography
title_fullStr Identification of malignant early repolarization pattern by late QRS activity in high‐resolution magnetocardiography
title_full_unstemmed Identification of malignant early repolarization pattern by late QRS activity in high‐resolution magnetocardiography
title_short Identification of malignant early repolarization pattern by late QRS activity in high‐resolution magnetocardiography
title_sort identification of malignant early repolarization pattern by late qrs activity in high‐resolution magnetocardiography
topic New Technologies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7358799/
https://www.ncbi.nlm.nih.gov/pubmed/31955494
http://dx.doi.org/10.1111/anec.12741
work_keys_str_mv AT iwakaminaotsugu identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT aibatakeshi identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT kamakurashiro identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT takakihiroshi identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT furukawatoshiakia identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT satotosiya identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT sunwenxu identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT shishidotoshiaki identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT nishimurakunihiro identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT yamadainoueyuko identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT nagasesatoshi identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT shimizuwataru identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT yasudasatoshi identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT sugimachimasaru identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography
AT kusanokengo identificationofmalignantearlyrepolarizationpatternbylateqrsactivityinhighresolutionmagnetocardiography