Cargando…
Absence of instabilities and intra-prosthetic dislocations at 7 to 11 years following THA using a fourth-generation cementless dual mobility acetabular cup
PURPOSE: Dual-mobility (DM) cups are increasingly used in total hip arthroplasty (THA) but there lacks literature on their long-term results. We aimed to investigate outcomes of a fourth-generation cementless DM acetabular cup at 7–11 years. METHODS: We retrospectively evaluated 240 consecutive hips...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7359208/ https://www.ncbi.nlm.nih.gov/pubmed/32661747 http://dx.doi.org/10.1186/s40634-020-00265-3 |
Sumario: | PURPOSE: Dual-mobility (DM) cups are increasingly used in total hip arthroplasty (THA) but there lacks literature on their long-term results. We aimed to investigate outcomes of a fourth-generation cementless DM acetabular cup at 7–11 years. METHODS: We retrospectively evaluated 240 consecutive hips that received cementless THA using the same dual mobility cup (Novae Sunfit TH) and femoral stem (Corail). Patients were recalled at ≥7 years to collect Oxford hip scores (OHS), Harris hip scores (HHS), and inspect for radiolucent lines and granulomas. Multi-variable analyses were performed to determine whether HHS or OHS were associated with pre- or intra-operative variables. RESULTS: At 8.4 ± 0.8 years (range, 7–11), 6 hips were revised (2.5%), 54 deceased (22.5%), and 14 could not be reached (5.8%). Four revisions (2 cup+stem, 2 liners only) were due to sepsis (1.7%), one (cup and stem) for trauma (0.4%), and one (stem) due to aseptic loosening (0.4%). For the remaining 166 hips, HHS was 83.6 ± 13.2 and OHS was 20.3 ± 6.7. Multi-variable analysis confirmed that HHS (β = − 0.38; p = 0.039) and OHS (β = 0.36; p < 0.001) worsened with age, and that OHS was worse for Charnley C patients (β = 3.17; p = 0.009). Neither granulomas nor radiolucenies were observed around any cups, but radiolucenies were seen around 25 stems (20.3%). CONCLUSIONS: This fourth-generation DM cup demonstrated satisfactory outcomes at 7–11 years, with no instabilities or cup revisions due to aseptic loosening. Better OHS was observed for younger patients and those presenting higher Charnley grade. LEVEL OF EVIDENCE: Level IV, retrospective case study. |
---|