Cargando…
Quantitative clinical assessment of motor function during and following LSVT-BIG® therapy
BACKGROUND: LSVT-BIG® is an intensively delivered, amplitude-oriented exercise therapy reported to improve mobility in individuals with Parkinson’s disease (PD). However, questions remain surrounding the efficacy of LSVT-BIG® when compared with similar exercise therapies. Instrumented clinical tests...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7359464/ https://www.ncbi.nlm.nih.gov/pubmed/32660495 http://dx.doi.org/10.1186/s12984-020-00729-8 |
_version_ | 1783559055206252544 |
---|---|
author | Flood, Matthew W. O’Callaghan, Ben P. F. Diamond, Paul Liegey, Jérémy Hughes, Graham Lowery, Madeleine M. |
author_facet | Flood, Matthew W. O’Callaghan, Ben P. F. Diamond, Paul Liegey, Jérémy Hughes, Graham Lowery, Madeleine M. |
author_sort | Flood, Matthew W. |
collection | PubMed |
description | BACKGROUND: LSVT-BIG® is an intensively delivered, amplitude-oriented exercise therapy reported to improve mobility in individuals with Parkinson’s disease (PD). However, questions remain surrounding the efficacy of LSVT-BIG® when compared with similar exercise therapies. Instrumented clinical tests using body-worn sensors can provide a means to objectively monitor patient progression with therapy by quantifying features of motor function, yet research exploring the feasibility of this approach has been limited to date. The aim of this study was to use accelerometer-instrumented clinical tests to quantify features of gait, balance and fine motor control in individuals with PD, in order to examine motor function during and following LSVT-BIG® therapy. METHODS: Twelve individuals with PD undergoing LSVT-BIG® therapy, eight non-exercising PD controls and 14 healthy controls were recruited to participate in the study. Functional mobility was examined using features derived from accelerometry recorded during five instrumented clinical tests: 10 m walk, Timed-Up-and-Go, Sit-to-Stand, quiet stance, and finger tapping. PD subjects undergoing therapy were assessed before, each week during, and up to 13 weeks following LSVT-BIG®. RESULTS: Accelerometry data captured significant improvements in 10 m walk and Timed-Up-and-Go times with LSVT-BIG® (p < 0.001), accompanied by increased stride length. Temporal features of the gait cycle were significantly lower following therapy, though no change was observed with measures of asymmetry or stride variance. The total number of Sit-to-Stand transitions significantly increased with LSVT-BIG® (p < 0.001), corresponding to a significant reduction of time spent in each phase of the Sit-to-Stand cycle. No change in measures related to postural or fine motor control was observed with LSVT-BIG®. PD subjects undergoing LSVT-BIG® showed significant improvements in 10 m walk (p < 0.001) and Timed-Up-and-Go times (p = 0.004) over a four-week period when compared to non-exercising PD controls, who showed no week-to-week improvement in any task examined. CONCLUSIONS: This study demonstrates the potential for wearable sensors to objectively quantify changes in motor function in response to therapeutic exercise interventions in PD. The observed improvements in accelerometer-derived features provide support for instrumenting gait and sit-to-stand tasks, and demonstrate a rescaling of the speed-amplitude relationship during gait in PD following LSVT-BIG®. |
format | Online Article Text |
id | pubmed-7359464 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-73594642020-07-17 Quantitative clinical assessment of motor function during and following LSVT-BIG® therapy Flood, Matthew W. O’Callaghan, Ben P. F. Diamond, Paul Liegey, Jérémy Hughes, Graham Lowery, Madeleine M. J Neuroeng Rehabil Research BACKGROUND: LSVT-BIG® is an intensively delivered, amplitude-oriented exercise therapy reported to improve mobility in individuals with Parkinson’s disease (PD). However, questions remain surrounding the efficacy of LSVT-BIG® when compared with similar exercise therapies. Instrumented clinical tests using body-worn sensors can provide a means to objectively monitor patient progression with therapy by quantifying features of motor function, yet research exploring the feasibility of this approach has been limited to date. The aim of this study was to use accelerometer-instrumented clinical tests to quantify features of gait, balance and fine motor control in individuals with PD, in order to examine motor function during and following LSVT-BIG® therapy. METHODS: Twelve individuals with PD undergoing LSVT-BIG® therapy, eight non-exercising PD controls and 14 healthy controls were recruited to participate in the study. Functional mobility was examined using features derived from accelerometry recorded during five instrumented clinical tests: 10 m walk, Timed-Up-and-Go, Sit-to-Stand, quiet stance, and finger tapping. PD subjects undergoing therapy were assessed before, each week during, and up to 13 weeks following LSVT-BIG®. RESULTS: Accelerometry data captured significant improvements in 10 m walk and Timed-Up-and-Go times with LSVT-BIG® (p < 0.001), accompanied by increased stride length. Temporal features of the gait cycle were significantly lower following therapy, though no change was observed with measures of asymmetry or stride variance. The total number of Sit-to-Stand transitions significantly increased with LSVT-BIG® (p < 0.001), corresponding to a significant reduction of time spent in each phase of the Sit-to-Stand cycle. No change in measures related to postural or fine motor control was observed with LSVT-BIG®. PD subjects undergoing LSVT-BIG® showed significant improvements in 10 m walk (p < 0.001) and Timed-Up-and-Go times (p = 0.004) over a four-week period when compared to non-exercising PD controls, who showed no week-to-week improvement in any task examined. CONCLUSIONS: This study demonstrates the potential for wearable sensors to objectively quantify changes in motor function in response to therapeutic exercise interventions in PD. The observed improvements in accelerometer-derived features provide support for instrumenting gait and sit-to-stand tasks, and demonstrate a rescaling of the speed-amplitude relationship during gait in PD following LSVT-BIG®. BioMed Central 2020-07-13 /pmc/articles/PMC7359464/ /pubmed/32660495 http://dx.doi.org/10.1186/s12984-020-00729-8 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Flood, Matthew W. O’Callaghan, Ben P. F. Diamond, Paul Liegey, Jérémy Hughes, Graham Lowery, Madeleine M. Quantitative clinical assessment of motor function during and following LSVT-BIG® therapy |
title | Quantitative clinical assessment of motor function during and following LSVT-BIG® therapy |
title_full | Quantitative clinical assessment of motor function during and following LSVT-BIG® therapy |
title_fullStr | Quantitative clinical assessment of motor function during and following LSVT-BIG® therapy |
title_full_unstemmed | Quantitative clinical assessment of motor function during and following LSVT-BIG® therapy |
title_short | Quantitative clinical assessment of motor function during and following LSVT-BIG® therapy |
title_sort | quantitative clinical assessment of motor function during and following lsvt-big® therapy |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7359464/ https://www.ncbi.nlm.nih.gov/pubmed/32660495 http://dx.doi.org/10.1186/s12984-020-00729-8 |
work_keys_str_mv | AT floodmattheww quantitativeclinicalassessmentofmotorfunctionduringandfollowinglsvtbigtherapy AT ocallaghanbenpf quantitativeclinicalassessmentofmotorfunctionduringandfollowinglsvtbigtherapy AT diamondpaul quantitativeclinicalassessmentofmotorfunctionduringandfollowinglsvtbigtherapy AT liegeyjeremy quantitativeclinicalassessmentofmotorfunctionduringandfollowinglsvtbigtherapy AT hughesgraham quantitativeclinicalassessmentofmotorfunctionduringandfollowinglsvtbigtherapy AT lowerymadeleinem quantitativeclinicalassessmentofmotorfunctionduringandfollowinglsvtbigtherapy |