Cargando…

Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis

BACKGROUND: Polymethylmethacrylate (PMMA) is commonly used for cement-augmented pedicle screw instrumentation (CAPSI) to improve the fixation stability and reduce the risk of screw loosening in the osteoporotic thoracolumbar spine. Biomechanical researches have shown that various dose of cement (1-3...

Descripción completa

Detalles Bibliográficos
Autores principales: Guo, Hui-zhi, Zhang, Shun-cong, Guo, Dan-qing, Ma, Yan-huai, Yuan, Kai, Li, Yong-xian, Peng, Jian-cheng, Li, Jing-lan, Liang, De, Tang, Yong-chao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7359596/
https://www.ncbi.nlm.nih.gov/pubmed/32660462
http://dx.doi.org/10.1186/s12891-020-03498-6
_version_ 1783559082217570304
author Guo, Hui-zhi
Zhang, Shun-cong
Guo, Dan-qing
Ma, Yan-huai
Yuan, Kai
Li, Yong-xian
Peng, Jian-cheng
Li, Jing-lan
Liang, De
Tang, Yong-chao
author_facet Guo, Hui-zhi
Zhang, Shun-cong
Guo, Dan-qing
Ma, Yan-huai
Yuan, Kai
Li, Yong-xian
Peng, Jian-cheng
Li, Jing-lan
Liang, De
Tang, Yong-chao
author_sort Guo, Hui-zhi
collection PubMed
description BACKGROUND: Polymethylmethacrylate (PMMA) is commonly used for cement-augmented pedicle screw instrumentation (CAPSI) to improve the fixation stability and reduce the risk of screw loosening in the osteoporotic thoracolumbar spine. Biomechanical researches have shown that various dose of cement (1-3 ml) can be injected to enhance screw stability. To date, there have been no studies on the relationship between adjacent segment degeneration and the volume of PMMA. This study aimed to explore the influence of CAPSI with different volumes of PMMA in osteoporotic lumbar vertebrae over adjacent segments by using finite element analysis. METHODS: Seven different finite element models were reconstructed and simulated under different loading conditions, including (1) an intact model, (2) three single-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml), and (3) three double-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml). To improve the accuracy of the finite element analysis, the models of the injectable pedicle screw and bone cement were created by using a three-dimensional scanning machine and the CAPSI patient’s CT data, respectively. The range of motion (ROM), the stress of intervertebral discs, and the stress of facet in the adjacent segment were comparatively analyzed among the different models. RESULTS: The ROMs of the different segments were compared with experimental data, with good agreement under the different load conditions (21.3°, 13.55°, 13.99°, and 6.11° in flexion, extension, bending, and rotation at L3-S1 level, respectively). Compared with the intact model, the ROM, disc stresses, and facet stress in adjacent segments were found to be higher in the six operative models. Otherwise, with a larger volume of PMMA injected, the ROM, disc stresses, and facet stress slightly increased at the adjacent segment. However, the differences were insignificant with the biggest difference less than 3.8%. CONCLUSIONS: CAPSI could increase the incidence of disk degeneration in the adjacent segment, while within a certain range, different volumes of PMMA provided an approximate impact over the adjacent segment degeneration.
format Online
Article
Text
id pubmed-7359596
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-73595962020-07-17 Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis Guo, Hui-zhi Zhang, Shun-cong Guo, Dan-qing Ma, Yan-huai Yuan, Kai Li, Yong-xian Peng, Jian-cheng Li, Jing-lan Liang, De Tang, Yong-chao BMC Musculoskelet Disord Research Article BACKGROUND: Polymethylmethacrylate (PMMA) is commonly used for cement-augmented pedicle screw instrumentation (CAPSI) to improve the fixation stability and reduce the risk of screw loosening in the osteoporotic thoracolumbar spine. Biomechanical researches have shown that various dose of cement (1-3 ml) can be injected to enhance screw stability. To date, there have been no studies on the relationship between adjacent segment degeneration and the volume of PMMA. This study aimed to explore the influence of CAPSI with different volumes of PMMA in osteoporotic lumbar vertebrae over adjacent segments by using finite element analysis. METHODS: Seven different finite element models were reconstructed and simulated under different loading conditions, including (1) an intact model, (2) three single-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml), and (3) three double-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml). To improve the accuracy of the finite element analysis, the models of the injectable pedicle screw and bone cement were created by using a three-dimensional scanning machine and the CAPSI patient’s CT data, respectively. The range of motion (ROM), the stress of intervertebral discs, and the stress of facet in the adjacent segment were comparatively analyzed among the different models. RESULTS: The ROMs of the different segments were compared with experimental data, with good agreement under the different load conditions (21.3°, 13.55°, 13.99°, and 6.11° in flexion, extension, bending, and rotation at L3-S1 level, respectively). Compared with the intact model, the ROM, disc stresses, and facet stress in adjacent segments were found to be higher in the six operative models. Otherwise, with a larger volume of PMMA injected, the ROM, disc stresses, and facet stress slightly increased at the adjacent segment. However, the differences were insignificant with the biggest difference less than 3.8%. CONCLUSIONS: CAPSI could increase the incidence of disk degeneration in the adjacent segment, while within a certain range, different volumes of PMMA provided an approximate impact over the adjacent segment degeneration. BioMed Central 2020-07-13 /pmc/articles/PMC7359596/ /pubmed/32660462 http://dx.doi.org/10.1186/s12891-020-03498-6 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Guo, Hui-zhi
Zhang, Shun-cong
Guo, Dan-qing
Ma, Yan-huai
Yuan, Kai
Li, Yong-xian
Peng, Jian-cheng
Li, Jing-lan
Liang, De
Tang, Yong-chao
Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis
title Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis
title_full Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis
title_fullStr Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis
title_full_unstemmed Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis
title_short Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis
title_sort influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3d finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7359596/
https://www.ncbi.nlm.nih.gov/pubmed/32660462
http://dx.doi.org/10.1186/s12891-020-03498-6
work_keys_str_mv AT guohuizhi influenceofcementaugmentedpediclescrewswithdifferentvolumesofpolymethylmethacrylateinosteoporoticlumbarvertebraeovertheadjacentsegmentsa3dfiniteelementanalysis
AT zhangshuncong influenceofcementaugmentedpediclescrewswithdifferentvolumesofpolymethylmethacrylateinosteoporoticlumbarvertebraeovertheadjacentsegmentsa3dfiniteelementanalysis
AT guodanqing influenceofcementaugmentedpediclescrewswithdifferentvolumesofpolymethylmethacrylateinosteoporoticlumbarvertebraeovertheadjacentsegmentsa3dfiniteelementanalysis
AT mayanhuai influenceofcementaugmentedpediclescrewswithdifferentvolumesofpolymethylmethacrylateinosteoporoticlumbarvertebraeovertheadjacentsegmentsa3dfiniteelementanalysis
AT yuankai influenceofcementaugmentedpediclescrewswithdifferentvolumesofpolymethylmethacrylateinosteoporoticlumbarvertebraeovertheadjacentsegmentsa3dfiniteelementanalysis
AT liyongxian influenceofcementaugmentedpediclescrewswithdifferentvolumesofpolymethylmethacrylateinosteoporoticlumbarvertebraeovertheadjacentsegmentsa3dfiniteelementanalysis
AT pengjiancheng influenceofcementaugmentedpediclescrewswithdifferentvolumesofpolymethylmethacrylateinosteoporoticlumbarvertebraeovertheadjacentsegmentsa3dfiniteelementanalysis
AT lijinglan influenceofcementaugmentedpediclescrewswithdifferentvolumesofpolymethylmethacrylateinosteoporoticlumbarvertebraeovertheadjacentsegmentsa3dfiniteelementanalysis
AT liangde influenceofcementaugmentedpediclescrewswithdifferentvolumesofpolymethylmethacrylateinosteoporoticlumbarvertebraeovertheadjacentsegmentsa3dfiniteelementanalysis
AT tangyongchao influenceofcementaugmentedpediclescrewswithdifferentvolumesofpolymethylmethacrylateinosteoporoticlumbarvertebraeovertheadjacentsegmentsa3dfiniteelementanalysis