Cargando…
Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness
BACKGROUND/AIMS: To assess the agreement in measuring retinal nerve fibre layer (RNFL) thickness between spectral-domain (SD; Cirrus HD, Carl Zeiss Meditec, USA) optical coherence tomography (OCT) and swept-source (SS; Plex Elite 9000, Carl Zeiss Meditec) OCT using an OCT angiography (OCTA) scanning...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7361033/ https://www.ncbi.nlm.nih.gov/pubmed/31585965 http://dx.doi.org/10.1136/bjophthalmol-2019-314706 |
_version_ | 1783559331176775680 |
---|---|
author | Tan, Bingyao Chua, Jacqueline Harish, Thiyagrajan Lau, Amanda Gan, Alfred Tau Liang Tan, Yar Li Wong, Damon W K Chong, Rachel Shujuan Ang, Marcus Husain, Rahat Schmetterer, Leopold |
author_facet | Tan, Bingyao Chua, Jacqueline Harish, Thiyagrajan Lau, Amanda Gan, Alfred Tau Liang Tan, Yar Li Wong, Damon W K Chong, Rachel Shujuan Ang, Marcus Husain, Rahat Schmetterer, Leopold |
author_sort | Tan, Bingyao |
collection | PubMed |
description | BACKGROUND/AIMS: To assess the agreement in measuring retinal nerve fibre layer (RNFL) thickness between spectral-domain (SD; Cirrus HD, Carl Zeiss Meditec, USA) optical coherence tomography (OCT) and swept-source (SS; Plex Elite 9000, Carl Zeiss Meditec) OCT using an OCT angiography (OCTA) scanning protocol. METHODS: 57 participants (12 glaucomatous, 8 ocular hypertensive and 74 normal eyes) were scanned with two OCT instruments by a single experienced operator on the same day. Circumpapillary RNFL thicknesses were automatically segmented for SD-OCT and manually segmented for SS-OCTA scans. Agreement of global RNFL thickness, as well as average thickness in four quadrants was assessed using intraclass correlation coefficients (ICCs). RESULTS: There was excellent agreement in the inferior and superior quadrants and the global (all ICC >0.90), followed by good agreement in the temporal (ICC=0.79) and nasal (ICC=0.73) quadrants. The ICC values were similar in the subgroups except within the ocular hypertension group, where the nasal quadrant was less agreeable (ICC=0.31). SS-OCTA-derived RNFL thickness was on average 3 µm thicker than SD-OCT, particularly in the nasal (69.7±11.5 µm vs 66.3±9.3 µm; p<0.001) and temporal (75.6±13.7 µm vs 67.9±12.3 µm; p<0.001) quadrants. CONCLUSIONS: RNFL measurements taken with SS-OCTA have good-to-excellent agreement with SD-OCT, which suggests that the RNFL thickness can be sufficiently extracted from wide-field OCTA scans. |
format | Online Article Text |
id | pubmed-7361033 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-73610332020-07-16 Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness Tan, Bingyao Chua, Jacqueline Harish, Thiyagrajan Lau, Amanda Gan, Alfred Tau Liang Tan, Yar Li Wong, Damon W K Chong, Rachel Shujuan Ang, Marcus Husain, Rahat Schmetterer, Leopold Br J Ophthalmol Clinical Science BACKGROUND/AIMS: To assess the agreement in measuring retinal nerve fibre layer (RNFL) thickness between spectral-domain (SD; Cirrus HD, Carl Zeiss Meditec, USA) optical coherence tomography (OCT) and swept-source (SS; Plex Elite 9000, Carl Zeiss Meditec) OCT using an OCT angiography (OCTA) scanning protocol. METHODS: 57 participants (12 glaucomatous, 8 ocular hypertensive and 74 normal eyes) were scanned with two OCT instruments by a single experienced operator on the same day. Circumpapillary RNFL thicknesses were automatically segmented for SD-OCT and manually segmented for SS-OCTA scans. Agreement of global RNFL thickness, as well as average thickness in four quadrants was assessed using intraclass correlation coefficients (ICCs). RESULTS: There was excellent agreement in the inferior and superior quadrants and the global (all ICC >0.90), followed by good agreement in the temporal (ICC=0.79) and nasal (ICC=0.73) quadrants. The ICC values were similar in the subgroups except within the ocular hypertension group, where the nasal quadrant was less agreeable (ICC=0.31). SS-OCTA-derived RNFL thickness was on average 3 µm thicker than SD-OCT, particularly in the nasal (69.7±11.5 µm vs 66.3±9.3 µm; p<0.001) and temporal (75.6±13.7 µm vs 67.9±12.3 µm; p<0.001) quadrants. CONCLUSIONS: RNFL measurements taken with SS-OCTA have good-to-excellent agreement with SD-OCT, which suggests that the RNFL thickness can be sufficiently extracted from wide-field OCTA scans. BMJ Publishing Group 2020-07 2019-10-04 /pmc/articles/PMC7361033/ /pubmed/31585965 http://dx.doi.org/10.1136/bjophthalmol-2019-314706 Text en © Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Clinical Science Tan, Bingyao Chua, Jacqueline Harish, Thiyagrajan Lau, Amanda Gan, Alfred Tau Liang Tan, Yar Li Wong, Damon W K Chong, Rachel Shujuan Ang, Marcus Husain, Rahat Schmetterer, Leopold Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness |
title | Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness |
title_full | Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness |
title_fullStr | Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness |
title_full_unstemmed | Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness |
title_short | Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness |
title_sort | comparison of a commercial spectral-domain oct and swept-source oct based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness |
topic | Clinical Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7361033/ https://www.ncbi.nlm.nih.gov/pubmed/31585965 http://dx.doi.org/10.1136/bjophthalmol-2019-314706 |
work_keys_str_mv | AT tanbingyao comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness AT chuajacqueline comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness AT harishthiyagrajan comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness AT lauamanda comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness AT ganalfredtauliang comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness AT tanyarli comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness AT wongdamonwk comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness AT chongrachelshujuan comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness AT angmarcus comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness AT husainrahat comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness AT schmettererleopold comparisonofacommercialspectraldomainoctandsweptsourceoctbasedonanangiographyscanformeasuringcircumpapillaryretinalnervefibrelayerthickness |