Cargando…
Automated pencil electrode formation platform to realize uniform and reproducible graphite electrodes on paper for microfluidic fuel cells
Graphite pencil stroked electrodes for paper-based Microfluidic devices are gaining immense attention due to their electrochemical properties, cost efficiency, and ease-of-use. However, their widespread use has been hindered by the challenges associated with their manual fabrication such as non-unif...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7363794/ https://www.ncbi.nlm.nih.gov/pubmed/32669600 http://dx.doi.org/10.1038/s41598-020-68579-x |
_version_ | 1783559709017505792 |
---|---|
author | Rao, Lanka Tata Rewatkar, Prakash Dubey, Satish Kumar Javed, Arshad Goel, Sanket |
author_facet | Rao, Lanka Tata Rewatkar, Prakash Dubey, Satish Kumar Javed, Arshad Goel, Sanket |
author_sort | Rao, Lanka Tata |
collection | PubMed |
description | Graphite pencil stroked electrodes for paper-based Microfluidic devices are gaining immense attention due to their electrochemical properties, cost efficiency, and ease-of-use. However, their widespread use has been hindered by the challenges associated with their manual fabrication such as non-uniformity in graphite deposition, applied pressure, etc. This work presents the design and development of an automated graphite pencil stroking device for graphite electrode fabrication with high efficiency through a compact, inexpensive and automatic process, with reduced fabrication time and human intervention leading to more uniformity. The motion platform of Graphtec plotter was used to create multiple strokes with the help of the proposed device. Such inexpensive graphite electrodes (less than the US $1) have been observed to be porous in nature, acting as diffusion agents. The automated graphite electrodes were used to study the performance of microfluidic paper fuel cells (MPFCs) with formic acid, oxygen, and sulphuric acid acting as fuel, oxidising agent and electrolyte respectively. From this configuration, the maximum current density and power density were measured to be 1,305.5 µA cm(−2) and 135.5 µW cm(−2), respectively at 0.3 V stable OCP at 100 strokes. Overall, the study enumerates the development of an automated pencil stroke device for fabricating graphite electrodes, which can potentially be harnessed in numerous miniaturized paper based applications. |
format | Online Article Text |
id | pubmed-7363794 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-73637942020-07-16 Automated pencil electrode formation platform to realize uniform and reproducible graphite electrodes on paper for microfluidic fuel cells Rao, Lanka Tata Rewatkar, Prakash Dubey, Satish Kumar Javed, Arshad Goel, Sanket Sci Rep Article Graphite pencil stroked electrodes for paper-based Microfluidic devices are gaining immense attention due to their electrochemical properties, cost efficiency, and ease-of-use. However, their widespread use has been hindered by the challenges associated with their manual fabrication such as non-uniformity in graphite deposition, applied pressure, etc. This work presents the design and development of an automated graphite pencil stroking device for graphite electrode fabrication with high efficiency through a compact, inexpensive and automatic process, with reduced fabrication time and human intervention leading to more uniformity. The motion platform of Graphtec plotter was used to create multiple strokes with the help of the proposed device. Such inexpensive graphite electrodes (less than the US $1) have been observed to be porous in nature, acting as diffusion agents. The automated graphite electrodes were used to study the performance of microfluidic paper fuel cells (MPFCs) with formic acid, oxygen, and sulphuric acid acting as fuel, oxidising agent and electrolyte respectively. From this configuration, the maximum current density and power density were measured to be 1,305.5 µA cm(−2) and 135.5 µW cm(−2), respectively at 0.3 V stable OCP at 100 strokes. Overall, the study enumerates the development of an automated pencil stroke device for fabricating graphite electrodes, which can potentially be harnessed in numerous miniaturized paper based applications. Nature Publishing Group UK 2020-07-15 /pmc/articles/PMC7363794/ /pubmed/32669600 http://dx.doi.org/10.1038/s41598-020-68579-x Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Rao, Lanka Tata Rewatkar, Prakash Dubey, Satish Kumar Javed, Arshad Goel, Sanket Automated pencil electrode formation platform to realize uniform and reproducible graphite electrodes on paper for microfluidic fuel cells |
title | Automated pencil electrode formation platform to realize uniform and reproducible graphite electrodes on paper for microfluidic fuel cells |
title_full | Automated pencil electrode formation platform to realize uniform and reproducible graphite electrodes on paper for microfluidic fuel cells |
title_fullStr | Automated pencil electrode formation platform to realize uniform and reproducible graphite electrodes on paper for microfluidic fuel cells |
title_full_unstemmed | Automated pencil electrode formation platform to realize uniform and reproducible graphite electrodes on paper for microfluidic fuel cells |
title_short | Automated pencil electrode formation platform to realize uniform and reproducible graphite electrodes on paper for microfluidic fuel cells |
title_sort | automated pencil electrode formation platform to realize uniform and reproducible graphite electrodes on paper for microfluidic fuel cells |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7363794/ https://www.ncbi.nlm.nih.gov/pubmed/32669600 http://dx.doi.org/10.1038/s41598-020-68579-x |
work_keys_str_mv | AT raolankatata automatedpencilelectrodeformationplatformtorealizeuniformandreproduciblegraphiteelectrodesonpaperformicrofluidicfuelcells AT rewatkarprakash automatedpencilelectrodeformationplatformtorealizeuniformandreproduciblegraphiteelectrodesonpaperformicrofluidicfuelcells AT dubeysatishkumar automatedpencilelectrodeformationplatformtorealizeuniformandreproduciblegraphiteelectrodesonpaperformicrofluidicfuelcells AT javedarshad automatedpencilelectrodeformationplatformtorealizeuniformandreproduciblegraphiteelectrodesonpaperformicrofluidicfuelcells AT goelsanket automatedpencilelectrodeformationplatformtorealizeuniformandreproduciblegraphiteelectrodesonpaperformicrofluidicfuelcells |