Cargando…

Fluorescent artificial receptor-based membrane assay (FARMA) for spatiotemporally resolved monitoring of biomembrane permeability

The spatiotemporally resolved monitoring of membrane translocation, e.g., of drugs or toxins, has been a long-standing goal. Herein, we introduce the fluorescent artificial receptor-based membrane assay (FARMA), a facile, label-free method. With FARMA, the permeation of more than hundred organic com...

Descripción completa

Detalles Bibliográficos
Autores principales: Biedermann, Frank, Ghale, Garima, Hennig, Andreas, Nau, Werner M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7363885/
https://www.ncbi.nlm.nih.gov/pubmed/32669621
http://dx.doi.org/10.1038/s42003-020-1108-9
_version_ 1783559730110660608
author Biedermann, Frank
Ghale, Garima
Hennig, Andreas
Nau, Werner M.
author_facet Biedermann, Frank
Ghale, Garima
Hennig, Andreas
Nau, Werner M.
author_sort Biedermann, Frank
collection PubMed
description The spatiotemporally resolved monitoring of membrane translocation, e.g., of drugs or toxins, has been a long-standing goal. Herein, we introduce the fluorescent artificial receptor-based membrane assay (FARMA), a facile, label-free method. With FARMA, the permeation of more than hundred organic compounds (drugs, toxins, pesticides, neurotransmitters, peptides, etc.) through vesicular phospholipid bilayer membranes has been monitored in real time (µs-h time scale) and with high sensitivity (nM-µM concentration), affording permeability coefficients across an exceptionally large range from 10(–9)–10(–3) cm s(–1). From a fundamental point of view, FARMA constitutes a powerful tool to assess structure-permeability relationships and to test biophysical models for membrane passage. From an applied perspective, FARMA can be extended to high-throughput screening by adaption of the microplate reader format, to spatial monitoring of membrane permeation by microscopy imaging, and to the compartmentalized monitoring of enzymatic activity.
format Online
Article
Text
id pubmed-7363885
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-73638852020-07-20 Fluorescent artificial receptor-based membrane assay (FARMA) for spatiotemporally resolved monitoring of biomembrane permeability Biedermann, Frank Ghale, Garima Hennig, Andreas Nau, Werner M. Commun Biol Article The spatiotemporally resolved monitoring of membrane translocation, e.g., of drugs or toxins, has been a long-standing goal. Herein, we introduce the fluorescent artificial receptor-based membrane assay (FARMA), a facile, label-free method. With FARMA, the permeation of more than hundred organic compounds (drugs, toxins, pesticides, neurotransmitters, peptides, etc.) through vesicular phospholipid bilayer membranes has been monitored in real time (µs-h time scale) and with high sensitivity (nM-µM concentration), affording permeability coefficients across an exceptionally large range from 10(–9)–10(–3) cm s(–1). From a fundamental point of view, FARMA constitutes a powerful tool to assess structure-permeability relationships and to test biophysical models for membrane passage. From an applied perspective, FARMA can be extended to high-throughput screening by adaption of the microplate reader format, to spatial monitoring of membrane permeation by microscopy imaging, and to the compartmentalized monitoring of enzymatic activity. Nature Publishing Group UK 2020-07-15 /pmc/articles/PMC7363885/ /pubmed/32669621 http://dx.doi.org/10.1038/s42003-020-1108-9 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Biedermann, Frank
Ghale, Garima
Hennig, Andreas
Nau, Werner M.
Fluorescent artificial receptor-based membrane assay (FARMA) for spatiotemporally resolved monitoring of biomembrane permeability
title Fluorescent artificial receptor-based membrane assay (FARMA) for spatiotemporally resolved monitoring of biomembrane permeability
title_full Fluorescent artificial receptor-based membrane assay (FARMA) for spatiotemporally resolved monitoring of biomembrane permeability
title_fullStr Fluorescent artificial receptor-based membrane assay (FARMA) for spatiotemporally resolved monitoring of biomembrane permeability
title_full_unstemmed Fluorescent artificial receptor-based membrane assay (FARMA) for spatiotemporally resolved monitoring of biomembrane permeability
title_short Fluorescent artificial receptor-based membrane assay (FARMA) for spatiotemporally resolved monitoring of biomembrane permeability
title_sort fluorescent artificial receptor-based membrane assay (farma) for spatiotemporally resolved monitoring of biomembrane permeability
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7363885/
https://www.ncbi.nlm.nih.gov/pubmed/32669621
http://dx.doi.org/10.1038/s42003-020-1108-9
work_keys_str_mv AT biedermannfrank fluorescentartificialreceptorbasedmembraneassayfarmaforspatiotemporallyresolvedmonitoringofbiomembranepermeability
AT ghalegarima fluorescentartificialreceptorbasedmembraneassayfarmaforspatiotemporallyresolvedmonitoringofbiomembranepermeability
AT hennigandreas fluorescentartificialreceptorbasedmembraneassayfarmaforspatiotemporallyresolvedmonitoringofbiomembranepermeability
AT nauwernerm fluorescentartificialreceptorbasedmembraneassayfarmaforspatiotemporallyresolvedmonitoringofbiomembranepermeability